Laserfiche WebLink
• Corporadon <br /> ember of The IT Group <br /> Ms. Devra Lewis Project 812717 <br /> April 9, 2001 <br /> Page 4 <br /> This error was not detected in our review. <br /> • Figure 9 has a value of 1,700 ppb contoured inside the 5,000 ppb contour line; <br /> This is also an error that was not detected in our review. <br /> • Figure 14 has an 11,000 ppb concentration not contoured; <br /> The 11,000 gg/L concentration was not included within a contour because we had no data <br /> from surrounding wells. Additional groundwater analytical data in this area will be <br /> generated as part of the expanded groundwater monitoring program and will be included in <br /> the quarterly isoconcentration maps. <br /> • Figure 18 has a value of 369 contoured closer to the 100 contour line than a 286 value; <br /> The location of the contour line in the area of the 369 gg/L value was based on our <br /> interpretation of the concentration gradient in this area. Historical groundwater analytical <br /> data indicates that petroleum hydrocarbons have not been detected in upgradient <br /> groundwater samples (north and northwest). Based on these data we have inferred that the <br /> concentration gradients in this area are steep. <br /> • Figure 18 has a value of<1,000 within the <50 contour line; and <br /> The analytical laboratory diluted the D-Zone groundwater sample from CPT CPT/H00-05 <br /> which raised the lower reporting limit for this sample from the standard 50 µg/L to 1,000 <br /> µg/L. TPHD was only detected in groundwater samples from two of the CPTs at <br /> concentrations of 268 gg/L at CPT/H00-03 and 369 gg/L at CPT/H00-08. Both of these <br /> detection's were at CPTs located downgradient of the STTC facilities. Based on this data <br /> we inferred that the TPHD would not likely be detected in groundwater samples within the <br /> D-Zone at this location. TPHD concentrations in the D-Zone in this area will be further <br /> evaluated as part of the expanded groundwater monitoring well program. <br /> • Figure 22 has a value of<2,000 outside the <50 contour line. <br /> The analytical laboratory diluted the D-Zone groundwater sample from CPT CPT/H00-05 <br /> which raised the lower reporting limit for this sample from the standard 50 gg/L to 2,000 <br /> gg/L. TPHD was only detected in groundwater samples from two of the CPTs at <br /> concentration of 126 gg/L at CPT/H00-09 and 392 gg/L at CPT/H00-03. Both of these <br /> detection's were at CPTs located downgradient of the STTC facilities. Based on this data <br /> we inferred that the TPHD would not likely be detected in this area. TPHD concentrations <br /> in the D-Zone in this area will be further evaluated as part of the expanded groundwater <br /> monitoring well program <br /> IT and the STTC (Jeff Baker of Tesoro Petroleum) would appreciate the opportunity to meet with <br /> you on-site at the Stockton Terminals to discuss project progress and provide a tour of this <br /> IT CORPORATION <br /> SAC:\C:\My DocumenwProjects\Pon ofStocktom.CPT HP Study\Response to Comments.doc-98\it 1 <br /> 812717 <br />