Laserfiche WebLink
r <br /> N <br /> Northern CaiifoTnia Office 5075 Commercial' Circle Suite A <br /> Concord ; CA 94520 ( 9 2 5 ) 363 - 7322 Fax ( 925 ) 363 - 7275 <br /> terminated at ten (10) feet below grade, unless further penetration is refused, or <br /> groundwater is encountered, whichever occurs first. In either of the latter cases, <br /> the boring and/or probe push will be terminated and a sample of the soil will be <br /> collected for laboratory analysis. <br /> Prior to commencing work, all drilling and/or probe equipment will be decontaminated by <br /> steam cleaning and pressure washing. (Cleaning with Alconox with a distilled water rinse <br /> is acceptable.) Auger and other sampling equipment will be decontaminated between <br /> Borings and between probe pushes. <br /> Undisturbed soil samples will be collected throughout the entire depth at 5'intervals, <br /> using split-spoon drive samplers or Shelby tubes, and of all probe pushes inside of the <br /> hollow push rods. <br /> All samples will be field screened for the presence of hydrocarbons using a portable <br /> hydrocarbon vapor analyzer(PID or equivalent). Field screening values shall be recorded <br /> on the boring logs. <br /> A total of(3) soil and (3) water samples (if encountered) will be collected from each site <br /> for laboratory analysis. One sample from the UST area exhibiting the highest PID or <br /> equivalent, one sample from the dispenser area exhibiting the highest PID or equivalent, <br /> and one more sample based on consultant's expertise. <br /> If groundwater is not detected during the initial investigation onsite, a minimum of two <br /> borings may be completed to a depth where groundwater is encountered, or to a <br /> maximum depth of 50 feet from the surface. The basis will be one of two criteria: <br /> A) GW is anticipated to be found between 25' to 50' <br /> B) Based on Soil and site conditions, consultant believes UST release plume would not <br /> be detected at 25'. <br /> If groundwater is not encountered within 50 feet of the surface, the boring will be <br /> terminated, and 2 soil samples from each boring, chosen by the Consultant, will be <br /> submitted for laboratory analysis. From any boring in which groundwater is still not <br /> encountered, 2 soil samples from each boring, chosen by the Consultant, will be <br /> submitted for laboratory analysis. (Subject to soil sample criterion) <br /> If groundwater is encountered, the following shall be conducted: <br /> In a Probe Assessment, a "pull back" sampling screen toot shall be used in the probe or a <br /> temporary well shall be installed. A groundwater sample shall be collected by purging <br /> the screen or well and following standard industry protocol for groundwater sampling. A <br /> temporary piezometer sealed to prevent surface intrusion may be used in lieu of a <br /> temporary well. Soil at the groundwater interface should be field screened to determine <br /> I <br /> whether or not soil at the interface should be collected for laboratory analysis. <br /> I <br />