Laserfiche WebLink
' 306620 Project Team <br /> March 28, 2007 <br /> ' Page 5 <br /> ' Table 3 <br /> ' Pressure and Air Flow Rates in Sparge Wells Measured on March 23, 2007 <br /> ' Air Breakthrough Pressure at Stabilized Operating Stabilized Operating Flow <br /> Sparge the Well Head (psi) Pressure at the Well Rate Measured at the Well <br /> Well Head (psi) Head (SCFM) <br /> ' AS-33 65 45 19 <br /> MW-23S 60-80 (pressure was 47 10 <br /> fluctuating just prior to <br /> breakthrough) <br /> A final attempt to establish flow in well MW-23S utilizing the air sparge conveyance piping was <br /> conducted on March 23, 2007. The trailer-mounted compressor was attached to the air sparge <br /> ' conveyance piping in the compound to verify the integrity of the underground conveyance piping. <br /> Breakthrough pressure, stabilized operating pressure, and stabilized flow rate were measured at the <br /> wellhead while air was being fed to the air sparge piping at the remediation compound. The test was <br /> ' interrupted because water was observed in the rotameter. However, by that time, several readings of <br /> the stabilized operating pressure and flow rate had already been recorded. The water observed in the <br /> rotameter at well MW-23S is assumed to have been in the sparge conveyance lines. <br /> The following measurements were collected on March 23, 2007 with the rented compressor connected <br /> to the air sparge conveyance line in the remediation compound: <br /> Table 4 <br /> Pressure and Air Flow Rates for MW-23S with Sufficient Compressor Capacity at the Compound <br /> ' Air Breakthrough Pressure Stabilized Operating Stabilized Operating Flow <br /> Sparge at the Well Head (psi) Pressure at the Well Rate Measured <br /> at the Well <br /> Well Head (psi) ) <br /> ' MW-23S 60 52 g <br /> ' The March 23, 2007 tests confirm that air flow can be established in wells on both sides of Robinhood <br /> Drive through the use of a compressor with a higher-pressure capacity than is currently operated at the <br /> ' site. The existing air sparge conveyance piping can be used to establish air flow in wells on the north <br /> side of Robinhood Drive, but water in the lines indicate that a leak exists and that conveyance line under <br /> A Trusted Global Environmental,Health and Safety Partner <br /> ' Sparge Flow Rate <br /> Summary_Stoddon_306620 Final.doc <br />