My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007910
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5400
>
2900 - Site Mitigation Program
>
PR0522692
>
ARCHIVED REPORTS_XR0007910
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2020 4:41:24 PM
Creation date
4/2/2020 3:41:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007910
RECORD_ID
PR0522692
PE
2957
FACILITY_ID
FA0015465
FACILITY_NAME
FORMER MONTGOMERY WARDS AUTO SRV CTR
STREET_NUMBER
5400
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10227008
CURRENT_STATUS
01
SITE_LOCATION
5400 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SOIL VAPOR EXTRACTION PILOT STUDY REPORT San Joaquin County <br /> Montgomery Ward Auto Service Center Public Health Services Department <br /> 5400 Pacific Avenue, Stockton CA Site Code 2163 <br /> i <br />' samples were not tested by EPA Method 8260 for confirmation All testingcompleted b <br /> was P Y <br /> a State of California certified hazardous waste testing laboratory <br /> Table 10 provides a summary of analytical results and Appendix J contains the laboratory <br /> reports Figure 10 shows these new data, along with past data, plotted on a site map These <br />' data suggest there are two separate plumes at the site (see Figure 11 ) <br /> The first plume is centered around soil borings B-6 and B-11, in the former UST area This <br /> plume extends in a northeast to southwest direction, covering a surface area of approximately <br />' 2,700 square feet The second plume is centered around monitoring well MW-2, near the <br /> former fuel islands, and covers a surface area of approximately 2,800 square feet <br /> In cross-section (see Figure 11 for location), the plume below the former gasoline UST <br />' excavation extends from approxnnately 15 feet bgs to approximately 60 feet bgs (see Figure <br /> 12 ) The plume appears to be fairly uniform in its lateral extent at all depths from the surface <br />' to the ground water table However, the plume shows higher concentrations in soil at deeper <br /> zones <br /> The cross section of the plume near the former fuel islands (see Figure 11 for location), <br />' extends from approximately 15 feet bgs to approximately 50 feet bgs (see Figure 13 ) In this <br /> plume, the maximum soil contaminant concentrations are found at shallow depths <br /> 7.0 VES AND AIR SPARGING PILOT TESTING <br /> This section presents the field measurements made before, during and after the SVE and Air <br />' Sparging pilot tests and also presents the results of the laboratory analyses performed during <br /> the tests All field measurements are provided in tables included in Appendix K <br /> 7.1 Measurements Prior to Startm Pilot Tests <br /> Prior to conducting the VES pilot test, the following measurements were recorded <br />' ■ Vapor concentrations using a field instrument in all VEW wells and soil vapor probes, <br /> ■ Pressure (vacuum) readings in VES wells and soil vapor probes, <br /> ■ Laboratory analyses of vapor concentrations in soil vapor probes, <br /> ■ Vacuum pressure and vapor concentrations at inlet to VES unit, and <br /> ■ Concentration of oxygen in wells <br /> The field measurement are included in Appendix K and the laboratory analyses of vapor <br /> concentrations are included in Appendix L <br /> 7.2 VES Pilot Tests Scenarios <br /> Three mayor soil vapor extraction pilot test scenarios were implemented as follows <br /> ■ The first test scenario involved extraction well VEW-lA Well VEW-1A was <br /> connected to the vapor extraction unit Air flow, vacuum pressure and vapor <br /> concentrations was measured at the VES manifold immediately after the VES unit was <br /> started At that time (at 1440 hrs), one soil vapor sample (VEW-1AO1440) was <br /> Project No 1232 - 8 - ENVIRONMENTAL AUDIT; INC � <br />
The URL can be used to link to this page
Your browser does not support the video tag.