My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007910
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5400
>
2900 - Site Mitigation Program
>
PR0522692
>
ARCHIVED REPORTS_XR0007910
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2020 4:41:24 PM
Creation date
4/2/2020 3:41:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007910
RECORD_ID
PR0522692
PE
2957
FACILITY_ID
FA0015465
FACILITY_NAME
FORMER MONTGOMERY WARDS AUTO SRV CTR
STREET_NUMBER
5400
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10227008
CURRENT_STATUS
01
SITE_LOCATION
5400 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SOIL VAPOR EXTRACTION PILOT STUDY REPORT <br /> San Joaquin County <br /> Montgomery Ward Auto Service Center Public Health Services Department <br /> 5400 Pacffic Avenue Stockton CA Site Code 2163 <br />' collected for laboratory analysis The Photo-iomzation Detector (PID) reading and <br /> laboratory analysis will serve as the baseline soil vapor concentrations Thereafter, <br />' PID readings were recorded at the adjacent wells and probes at approximately 30- <br /> minute intervals until two consecutive readings showed that steady state conditions had <br /> been reached At that time (at 1700 hrs), a second soil vapor sample (VEW-1AO1700) <br /> was collected for laboratory analysis Vacuum and vapor concentration measurements <br /> were also recorded at each soil probe and at the other extraction well (VEW-1B) <br /> ■ The second test scenario was identical to the first test except VEW-1B was used as the <br /> extraction well <br /> ■ The third test scenario involved both extraction wells VEW-1A and VEW-1B were <br />' both connected to the vapor extraction system The parameters specified earlier were <br /> recorded in 30 minutes intervals until steady state was reached for both wells together <br /> The field measurement are included in Appendix K and the laboratory analyses of vapor <br /> concentrations are included in Appendix L <br /> 7.3 Air Sparging Pilot Field Tests, <br /> To test effectiveness of air sparging, EAI conducted an air sparging test using the following <br /> criteria <br /> ■ Extraction using both VEW-1A and VEW-1B (lower screened interval was blocked off <br /> using a packer during this test), <br /> ■ Injection through VEW-1B using the injection system (through lower screened interval), <br /> ■ Injection pressure of 30 psi, and <br /> ■ Injection rate of 5 cfm <br /> During the air sparging test, EAI field personnel recorded the following parameters <br /> ■ Vacuum at all soil probes, <br /> ■ Concentration (using PID) of vapors at all soil probes and wells, <br /> N Concentration (by laboratory analysis) of vapors at VEW-1A & VEW-1B, <br /> ■ Dissolved oxygen in adjacent wells using field instrument, <br /> I ■ Dissolved oxygen in adjacent wells using laboratory analysis, <br /> ■ Biological parameters in adjacent wells using laboratory analysis, and <br /> 0 Vapor concentration, flow rates and oxygen at inlet to VES unit <br /> The field measurement are included in Appendix K and the laboratory analyses of vapor <br /> concentrations are included in Appendix L <br /> 1 7.4 LaboratoEy Analyses Of Vapor Sam les <br /> 1 The: vapor samples collected from the wells and the soil vapor probes were sent to a certified <br /> laboratory for analysis by EPA Method TO-14 Results reported by this analysis includes <br /> TPH-G and BTEX and are summarized in Table I I for soil vapor probes and in Table 12 for <br /> VES wells Laboratory Reports are included in Appendix L <br /> Project No 1232 - 9 - ENVIRONMENTAL AUDIT, INC <br />
The URL can be used to link to this page
Your browser does not support the video tag.