Laserfiche WebLink
' FOURTH QUARTER 1998 GROUND WATER MONITORING REPORT San Joaquin County <br /> Montgomery Ward Auto Service Center Puhlic Health Services Department <br />' 5400 Pacific Avenue,Stockton CA Site Code 2153 <br /> 2 2 GROUND WATER SAMPLING <br />' On December 22, 1998, ground water samples were collected by EAI from all ground water <br /> monitoring wells associated with the Montgomery Ward site Additionally, EAI sampled four of <br /> the vapor extraction wells (VEW-2B, VEW-3, VEW-4 and VEW-5) at the Site since these wells <br /> were screened near the top of the ground water Well VEW-213 Is screened between 35 to 50 <br /> feet bgs Wells VEW-3, VEW-4 and VEW-5 are screened between 20 to 30 feet and 40 to 50 <br /> feet with a blank section between 30 and 40 feet bgs Wells VEW 1 A (screened at 10 to 25 feet) <br /> and VEW-2 (screened at 15 to 35 feet) were not sampled Well VEW-113 was not sampled since <br />' it contained equipment which made the well water Inaccessible to sample <br /> Prior to sampling, the wells were purged using a Grundfos MP-1 submersible pump <br />' Temperature, conductivity, pH, and turbidity were recorded to evaluate the effectiveness of <br /> purging activities (see Appendix A) The wells were sampled in the order that purging activities <br /> were completed Water samples were collected from each well from just below the water surface <br /> using Voss Technologies disposable bottom bailers equipped with volatile organic compound <br />' sampling tips The use of these bailers precludes the potential for cross-contamination <br /> Each water sample was scaled in three 40-milliliter volatile organic analysis (VOA) vials with <br />' Teflon septa lined lids The VOA vials were completely filled so that no head space existed <br /> between the sample and the lids The samples were labeled with the sample point identification, <br /> preservative added, if any, date, time and EAI project number, and immediately placed Into a <br /> chilled ice chest The samples were kept chilled until delivered to the laboratory for analytical <br /> testing All samples were logged on a chain of custody record form (see Appendix B) <br /> 23 SAMPLING EQUIPMENT CLEANING PROTOCOL <br />' The submersible pump and hose system (Equipment), used only to purge the wells prior to <br /> sampling, was decontaminated between each event using the following procedure <br /> ■ The Equipment was flushed in a solution of Alconox detergent and tap water, and <br /> e The Equipment was flushed with tap water <br /> 24 EFFLUENT HANDLING <br /> All effluent generated during purging, sampling and equipment decontamination activities was <br /> sealed in labeled 55-gallon drums The drums were stored in a secured area on the Montgomery <br /> Ward site pending proper disposal <br /> 25 DELTA COLLEGE WELL <br /> In addition to the Unocal and Montgomery Ward site wells a Delta College irrigation well <br /> located west of Pacific Avenue was also sampled (see Table 2) <br /> IProject No 1232 - 2 - ENVIRONMENTAL AUDIT, INC <br />