Laserfiche WebLink
Kennedy Jenks <br /> B. When fines are removed, surge the full well screen length with a vented surge block 15 <br /> times. <br /> C. Repeat sediment removal, until the casing is cleared and use of a submersible pump is <br /> considered safe. <br /> D. Pump from the well, periodically lifting and lowering the pump over the wells screen. <br /> E. Pump until the water clarity reaches 5 ntu, or 10 casing volumes have been removed. <br /> 14. Develop each monitoring well. <br /> 15. When development of each well is discontinued, record the following field <br /> parameters/observations: <br /> Depth to water <br /> Temperature <br /> pH <br /> Specific conductance <br /> Turbidity <br /> Color <br /> D.5 Investigation-Derived Wastes <br /> Place groundwater produced by well development on the ground near the well, but in a manner that <br /> does not compromise safety or is unsightly. Kennedy Jenks is available to assist the client with <br /> options for disposition of groundwater. <br /> Monitoring Well Installation Work Plan, D-3 <br /> The Wine Group, Franzia Winery, Ripon, CA <br /> P.\1 S-Proj\2003-post archive\030120.XY_GW Mon Well Support\09-Reports\piecesWPP_D SOG Well_Const.doc <br />