Laserfiche WebLink
April 29, 2019 <br /> Community Development Department <br /> Building and Safety Division <br /> 221 West Pine St. <br /> Lodi, CA <br /> Plan Check Correction Letter <br /> Project: 2 W Oak Street <br /> Ginger Bugs <br /> • Please see plan check corrections listed below: <br /> Note Response <br /> F1 Fire extinguisher added to floor plan. See delta 1 revision on sheet A-1. <br /> F2 Noted. Application will be made with the Lodi Fire Department. No change to drawings. <br /> F3 Occupant load signage note added to delta 1 revision sheet A-1. <br /> F4 Address note added. Sett delta 1 revision sheet A-1. <br /> Al Occupant load calculations added. See delta 1 revisions sheet T-0. <br /> A2 a Sheet A-2 occupancy Ian added. Exit separation shown. <br /> A2 b Plans amended to show proper door swing. <br /> A2 c Panic hardware noted in door schedule sheet A-1. <br /> A2 d Emergency illuminating egress lighting and exit signs added to sheet A-2 <br /> A2 e Emergency illuminating egress lighting and exit signs added to sheet A-2 <br /> A2 9 Detail A was added to sheet A-2 showing tactile exit signage requirements <br /> DA1 1) Accessible entrance upgrades have been added. See door schedule and corresponding <br /> details illustrating requirements. <br /> DA1 2) An Accessible route to altered area is in existence. No change noted on drawings. All areas in <br /> design meet or exceed ADA minimum requirements. <br /> DA1 3) (2) Two accessible restrooms have been added to project. Project will consist of(2) two, all <br /> ender restrooms under CPC 422.2 exception (3). <br /> DA1 4 Accessible telephone did not exist previously. No change to drawings <br /> DA1 5 Accessible drinking fountain has been added. See delta 1 revisions. <br /> DA1 6 City is responsible for parking. No changes to drawings. <br /> DA2 Drinking fountain added. See delta 1 revisions. <br /> DA3 Clearance requirements have been added. Red line nots on ADA sheet A-3 have been <br /> amended. <br /> DA4 60" x 48 clear dimensions have been added to drawings. <br /> DA5 17"-18" from wall to water closed has been addressed on sheet A-3 <br /> DA6 Plans have been amended to show 18" centerline lavatory, see sheet A-2. <br /> DA7 Note has been added to sheet A-2 to direct water flush control to be located on open side. <br /> Please note this was listed on sheet A-3, however it was added to sheet A-2 for clarity. <br /> DA8 Detail 7/A-5 has been amended to chop toilet paper dispenser shall be located 7"-9" from front <br /> of water closet and not be located behind grab bar. <br /> DA9 Note on detail 5/A-5 has been modified to show a minimum of 48" to lowest line of braille and <br /> maximum of 60". <br /> DA10 Sales/ Service counter has been adjusted to 34" to meet ADA requirement <br />