Work Plan—Soil Boring Installation Page 4 <br /> 3291 S.Hwy 99 <br /> Project 472.2 <br /> July 16, 2007 <br /> laboratory analysis will be sealed with Teflon sheets or aluminum foil, capped <br /> with plastic end caps, secured with tape, labeled and placed in a cooler at 4° <br /> Celsius. Two to three soil samples from each boring will be submitted for <br /> laboratory analysis under chain-of-custody protocol. <br /> All sampling equipment will be thoroughly cleaned before and between uses. No <br /> soil cuttings will be generated during the Geo-Probe drilling process. Samples <br /> selected for laboratory analysis will be submitted to a State Certified analytical <br /> laboratory and tested as follows: <br /> • CAM-17 Metals by EPA method 6010 <br /> • Volatile Organic Compounds by EPA method 8260 <br /> • Semi-Volatile Organic Compounds by EPA method 8270 <br /> 3.0 REPORTING <br /> The information gathered during this phase of work will be presented in a <br /> report, which will include a description of the field work, results of sample <br /> analyses, and a discussion of their implications. The report will be prepared and <br /> signed by a registered Professional Geologist responsible for the work. <br /> 2937 Veneman Avenue, Suite B240 Geo-Phase Environmental Inc. Phone: (209)569-0293 <br /> Modesto, Ca 95356 Fax: (209)569-0295 <br />