Laserfiche WebLink
Periodic Inspection Requirements <br /> ConVault tanks of 5,000 gallons or less capacity are CATEGORY 1 TANKS. Owners of ConVault ASTs of this size are NOT <br /> required to employ Certined AST Inspectors to inspect their tanks to comply with the standard's requirements,but can be in <br /> compliance with the standard by inspecting the tanks themselves or having their employees inspect them.ConVault tanks <br /> larger than 5000 gallons,are also self inspected and only require inspection by a Certified Inspector after 20 years of service. <br /> What qualifications are required for the owner to self-inspecthis tank,andhowdoes the ownerneed to know what to inspect? <br /> Section 4 of the SP001 standard defines the qualifications of the Owner's Inspector as follows:"Periodic inspections are to be <br /> performed byan owner's inspector.The personnel performing these inspections shall be knowledgeable ofstoroge facility operations, <br /> the type ofAST and its associated components,and characteristics of the liquid stored° <br /> Section 6 of the standard STI SP001 explains what is meant by the PERIODIC AST INSPECTION — and what needs to be <br /> inspected and kept in the owner's AST records.These are simple and straight-forward tasks which can be performed by any <br /> competent owner or his employees.The standard makes it very easy to know what to do and what to check for by providing <br /> a check list in the standard's Appendix C.The first section requires filling in information about the owner and the ID of the <br /> l tank.The second section is the SP001 Monthly Inspection Checklist which consists of 9 easy to check,Yes or No questions <br /> such as, is there water in primary or secondary containment, are there visible signs of leakage around the tank, concrete <br /> pad,or ground,are all tank openings properly sealed,etc.The third section is the SP001 Annual Inspection Checklist which <br /> contains 27 questions with Yes or No answers and a space for comments, It should be noted that the Periodic Inspection <br /> must be performed in addition to the formal External Inspections. <br /> Simply put,the periodic inspection requirements are visual,documented inspections conducted by an owner's inspector,to <br /> assess the general AST conditions,as best as possible,without suspending AST'operations or removing the ASTfrom service. <br /> ConVault strongly encourages the use of the Monthly and Annual Inspection Checklists provided in SP001, and, in fact, <br /> requires some of these items be checked on a weekly basis as part of the ConVault warranty. <br /> See Pages 10-12 for a Con Vault specific Maintenance Checklist, <br /> A copy of ConVault's weekly/monthly/yearly checklist is available online at <br /> http-://www.convault.com/pdfdoc/checklist.pdf. <br /> i <br /> i <br /> l <br />