Laserfiche WebLink
pollution, resulting in closing down of the surrounding water wells The brine <br /> contamination has not been defined in this site's investigation but may be presumed to <br /> ' be either underlying or very close to the WO&S site as the Victor property is within 500 <br /> feet upgradient <br /> ' 2.1.4 Preliminary 9 Findin - Western Oil & Spreading-Acampo Plant Site <br /> Cleanup Goals <br /> prehininar t finda= and cleanup goals are summarized as follow <br /> ' The particular petroleum hydrocarbon contamination measured to date is encouraging <br /> I <br /> The groundwater contamination findings to date are minimal, but the contamination <br /> potential is not yet defined Depth of contamination and surface facilities render soil not <br /> readily amendable to excavation and offsite disposal In situ bio-remediation, <br /> I <br /> application of risk base analysis and cost effective remediation will be considered after <br /> the problem is further defined <br /> The isolated "shallow water body" reflected very low BTEX levels Further testing of <br /> lower strata and grab samples in the "shallow water body" will allow a more <br /> ' knowledgeable evaluation and chanting of remediation course <br /> I <br /> I <br /> I <br /> I <br /> ! <br /> I <br /> I <br /> 2-3 <br /> I <br />