EXECUTIVE SUMMARY <br /> The depth to groundwater was measured and water samples were collected from five monitor wells <br /> and the Gillies domestic well on June 8,2000 One of the monitor wells had been buried under road <br /> aggregate during recent gradmg activities and could not be located, and the monitor well on the <br /> adjacent property could not be sampled because the property owner was present for only a short <br /> tune The depth to groundwater m most wells was approximately 3 feet deeper than in April, and <br /> ranged between 47 and 50 feet As was true in April 1999, the groundwater flow direction is <br /> somewhat difficult to interpret and multiple interpretations are possible, but we favor the <br /> interpretation that the flow direction is to the southeast, toward the domestic well on the Barbot <br /> property located at 3851 Newton Road <br /> All samples were analyzed for TPH-diesel, TPH-gasoline and BTEX The sample from GT-10 was <br /> also analyzed for gasoline oxygenates Diesel and various gasoline compounds were detected in <br /> four of the six samples, at concentrations that are generally quite close to those in April 2000 and <br /> December 1999 Diesel was not detected in the Gillies domestic well <br /> 1 <br />