My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
14749
>
2231-2238 – Tiered Permitting Program
>
PR0515788
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2020 5:28:51 PM
Creation date
4/10/2020 5:18:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0515788
PE
2832
FACILITY_ID
FA0000482
FACILITY_NAME
3 b's truck & auto plaza
STREET_NUMBER
14749
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
000-027-346-4
CURRENT_STATUS
01
SITE_LOCATION
14749 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
01 August 2019 AdvancedGeo <br /> AGE Project No. 05-1278 Environmental <br /> Page 12 of 23 -� <br /> 3.7.1. Daily Inspection <br /> A Facility employee performs a complete walk-through of the Facility each day. This daily <br /> visual inspection involves: (1) looking for tank/piping damage or leakage, stained or <br /> discolored surface hardscape, or excessive accumulation of water in berm areas and (2) <br /> verifying that the drains are correctly working. <br /> 3.7.2. Monthly Inspection <br /> The checklist provided in Appendix B is used for monthly inspections by Facility <br /> personnel. The monthly inspections cover the following key elements: <br /> Observing AST exterior, pipes, and other equipment for signs of deterioration, leaks, <br /> corrosion, and thinning. <br /> • Observing AST foundations and supports for signs of instability or excessive <br /> settlement. <br /> • Observing AST fill and discharge pipes for signs of poor connection that could <br /> cause a discharge, and AST vent for obstructions and proper operation. <br /> • Observing the constructed secondary containment berm condition. <br /> • Verifying the proper functioning of overfill prevention systems. <br /> • Checking the inventory of discharge response equipment and restocking as <br /> needed. <br /> All problems regarding ASTs, piping, containment, or response equipment are <br /> immediately reported to the Facility Coordinator. Visible oil leaks from AST walls, piping, <br /> or other components are repaired as soon as possible to prevent a larger spill or a <br /> discharge to navigable waters or adjoining shorelines. Pooled oil is removed immediately <br /> upon discovery. <br /> Monthly inspections are documented, and records are signed by the Coordinator and <br /> maintained with this Plan for a period of at least three years, unless otherwise noted. <br /> 3.7.3. Annual Inspection <br /> Facility personnel perform a more thorough inspection of Facility equipment on an annual <br /> basis. This annual inspection complements the monthly inspection described above and <br /> is performed once each year using the checklist provided in Appendix B of this Plan. <br />
The URL can be used to link to this page
Your browser does not support the video tag.