My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
14749
>
2231-2238 – Tiered Permitting Program
>
PR0515788
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2020 5:28:51 PM
Creation date
4/10/2020 5:18:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0515788
PE
2832
FACILITY_ID
FA0000482
FACILITY_NAME
3 b's truck & auto plaza
STREET_NUMBER
14749
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
000-027-346-4
CURRENT_STATUS
01
SITE_LOCATION
14749 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
01 August 2019 AdvancedGeo <br /> AGE Project No. 05-1278 Environmental <br /> Page 16 of 23 <br /> 4.2.4. Corrosion Protection- 40 CFR 112.8(c)(4) <br /> Corrosion protection is provided for any underground piping by double wall containment <br /> of distribution pipes construction of non-corrosive fiber glass; cathodic testing is <br /> conducted, as deemed necessary. Testing documentation is kept in the office in the AST <br /> testing files for each AST that is tested. <br /> 4.2.5. Partially Buried and Bunkered Storage Tanks - 40 CFR 112.8(c)(5) <br /> This section is not applicable since there are no partially buried or bunkered storage tanks <br /> at this Facility. <br /> 4.2.6. Inspections and Tests - 40 CFR 112.8(c)(6) <br /> Visual inspections of ASTs by Facility personnel are performed according to the <br /> procedure described in this Plan. Leaks from tank seams, gaskets, rivets, and bolts are <br /> promptly corrected. Records of inspections and tests are signed by the inspector and kept <br /> at the Facility for at least three years, unless otherwise specified. <br /> The scope and schedule of certified inspections and tests performed on the Facility's <br /> ASTs are specified in STI Standard SP-001. The external inspection includes ultrasonic <br /> testing of the shell, as specified in the standard, or if recommended by the certified tank <br /> inspector to assess the integrity of the tank for continued oil storage. <br /> Records of certified tank inspections are kept at the Facility for at least three years, unless <br /> otherwise specified. Shell test comparison records are retained for the life of the tanks. <br /> Table 9 summarizes inspections and tests performed on ASTs. <br /> 4.2.7. Heating Coils - 40 CFR 112.8(c)(7) <br /> This section is not applicable since there are no ASTs equipped with heating coils at this <br /> Facility. <br /> 4.2.8. Overfill Prevention Systems - 40 CFR 112.8(c)(8) <br /> All tanks are equipped with a direct-reading level gauge. All tanks are equipped with a <br /> direct reading display at the loading area for use during oil/fuel delivery. ASTs equipped <br /> with liquid level sensing devices are tested on a monthly basis during the monthly <br /> inspection of the Facility, following manufacturer recommendations. Venting capacity is <br /> suitable for the fill and withdrawal rates. Facility personnel are informed of the filling <br /> operations to monitor the product level in the tanks. General secondary containment is <br />
The URL can be used to link to this page
Your browser does not support the video tag.