Laserfiche WebLink
Spill Prevention Control and Countermeasure Plan <br /> Food Express, Inc. <br /> 1250 Madruga Road <br /> FOOD EXPRESS,TINC. Lathrop, California 95330 <br /> May 2020 <br /> Page 22 <br /> conditions are present that would cause the AST to be more susceptible to a release (e.g. high <br /> pressures or marine environments). Consequently, ATC interprets SP001 to imply that unless <br /> extenuating or mitigation factors are present, a new AST's Certified Inspection should first occur <br /> after 20 years of service. <br /> The table below identifies the Category 1 containers between 5,001 and 30,000 gallons in <br /> capacity storing oil at the facility. The table also includes the container's age', and the date by <br /> which they will need to have a FCI performed by a STICI. If the year of manufacture cannot be <br /> established by the manufacturer's plate or otherwise determined, the ASTs will be assumed to be <br /> at least 20 years old and receive a FCI accordingly. <br /> Volume Manufacture Last FCI Next FCI <br /> MSA Container ID Contents <br /> allonsear ear ear <br /> MSA01 AST01 Motor Oil 12,000 1992 2017 20279 <br /> The FCI records are retained for at least three years in Appendix I. <br /> The Professional Engineer's Certification of this plan serves as verification of the recommended <br /> integrity testing approach. <br /> 13.6. INTERNAL HEATING COILS [40 CFR§112.8(C)(7)]: <br /> Not applicable since there are no internal heating coils at the facility. <br /> 13.7. CONTAINER OVERFILL PREVENTION [40 CFR §112.8(C)(8) & <br /> §112.12(C)(8)]: <br /> Prescribing proper overfill protection in accordance with §112.8(c)(8) & §112.12(c)(8) is <br /> complicated and any determination to add overfill protection devices has many considerations <br /> with the foremost being a.) Rate of oil transfer, b.) Oil space availability or ullage in the container <br /> being filled, and c.) The force behind the oil transfer (gravity versus powered [electrical, air, <br /> hydraulic powered]). <br /> The selection of type of oil storage containers, the outfitting of the containers with overflow <br /> preventing appurtenances, and the mechanisms and procedures for the transfer of oil, were <br /> designed collectively to prevent or minimize discharges due to overfilling. A refill operator is <br /> allowed maximum control over the transfer process when a.) The rate of oil transfer is slow, but <br /> not so slow to exceed the refill operators ability to concentrate on the task, b.) Lag time is for <br /> receiving information regarding oil remaining space availability in the destination container is low, <br /> time required to slow or stop the oil flow is slow. When one or more of these factors does not <br /> 8 If the year of manufacture cannot be determined,ASTs will be assumed to be 20 years old and receive FCI accordingly. <br /> 9 Interval determined by STICI during last FCI. <br /> JN Page 22 <br />