Laserfiche WebLink
Pep Boys#562 <br /> (d)All new tanks and ancillary equipment shall be tested for tightness prior to being covered, <br /> enclosed or placed in use. If a tank system is found not to be tight, all repairs necessary to <br /> remedy the leak(s) in the system shall be performed prior to the tank system being covered, <br /> enclosed,or placed in use. Each tank was pressure tested under at least 3 psi pressure by the <br /> manufacturer(See Appendix B). <br /> (e)Ancillary equipment shall be supported and protected against physical damage and excessive <br /> stress due to settlement,vibration, expansion or contraction. This assessment covers only the <br /> tanks. <br /> (f)The owner or operator shall provide the type and degree of corrosion protection necessary, <br /> based on the information provided under subsection (a)(3) of this section,to ensure the <br /> integrity of the tank system during use of the tank system.The installation of a corrosion <br /> protection system that is field fabricated shall be supervised by an independent corrosion expert <br /> to ensure proper installation. The tanks are located inside a building on a concrete foundation. <br /> The tanks are inspected daily by Pep Boys employees and an inspection log is kept. No corrosion <br /> protection equipment is required or necessary. <br /> (g)The owner or operator shall obtain and keep on file at the facility written statements by <br /> those persons required to certify the design of the tank system and supervise the installation of <br /> the tank system in accordance with the requirements of subsections (b)through (f)of this <br /> section to attest that the tank system was properly designed and installed and that repairs, <br /> pursuant to subsection (b) and (d)of this section were performed.These written statements <br /> shall also include the certification statement as required in section 66270.11(d)of this division. <br /> This report provides the necessary statements and certification. See engineer's qualifications in <br /> Appendix D. <br /> (h) this subsection applied only until January 24, 1998. <br /> (i)A generator or owner or operator authorized pursuant to Permit-by-Rule pursuant to Chapter <br /> 45 of this division, Conditional Authorization pursuant to HSC 25200.3, or Conditional Exemption <br /> pursuant to HSC 25201.5, operating a non-RCRA underground tank system or an underground <br /> tank system otherwise exempt from permitting requirements pursuant to the federal act, shall <br /> comply with the applicable standards of Title 23 of the California Code of Regulations relating to <br /> underground tank systems. Not applicable—the tanks are not underground. <br /> 7 <br />