My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1401
>
2800 - Aboveground Petroleum Storage Program
>
PR0514495
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2020 1:39:34 PM
Creation date
4/14/2020 12:51:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514495
PE
2227
FACILITY_ID
FA0011020
FACILITY_NAME
PEP BOYS #562
STREET_NUMBER
1401
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06208029
CURRENT_STATUS
01
SITE_LOCATION
1401 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pep Boys#562 <br /> (k)(2)design standard(s), if available,according to which the tank and ancillary equipment were <br /> or will be constructed and all of the following information. <br /> (k)(2)(A) material of construction;All tanks are made of steel.See Table 1. <br /> (k)(2)(B) material thickness and the method used to determine the thickness;thicknesses were <br /> measured with an ultrasonic gauge,see Table 11 for measurements. <br /> (k)(2)(C)description of tank system piping(material, diameter); this certification is for the tanks <br /> only. <br /> (k)(2)(D)description of any internal and external pumps;Not applicable—there are no pumps on <br /> or in the tanks. <br /> (k)(2)(E)sketch or drawing of tank including dimensions. See tank dimensions in Table 1, tank <br /> drawings in Figures 3-8, and photographs of tanks in Appendix A. <br /> (k)(3)documented age of the tank system (if tank was previously used),if available, (otherwise, <br /> an estimate of the age); The three tanks are 14 years old.See Table U. <br /> (k)(4)description and evaluation of any leak detection equipment—describe if any. The tanks <br /> are inspected by Pep Boys employees daily and an inspection log is kept. <br /> (k)(5)description and evaluation of any corrosion protection equipment,devices,or material: <br /> All tanks are located inside a building. They are inspected by Pep Boys employees daily and an <br /> inspection log is kept. No corrosion protection equipment or devices are required or necessary. <br /> (k)(6)description and evaluation of any spill prevention or overfill equipment. The tanks are <br /> inspected by Pep Boys employees daily and an inspection log is kept. <br /> (k)(7)description and evaluation of secondary containment for the tank system (secondary <br /> containment must meet minimum standards as specified in subsections 0)(1)through 0)(3)of <br /> this section) including applicable secondary containment for ancillary equipment as required in <br /> subsection 66265.193(f);All tanks are double walled and provide their own secondary <br /> containment. See Table V. <br /> (k)(8) hazardous characteristics of the waste(s)that have been or will be handled; The waste oil, <br /> waste coolant and waste water are California hazardous due to toxicity. See Table 111. <br /> 9 <br />