My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1645
>
2200 - Hazardous Waste Program
>
PR0518783
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2020 2:21:51 PM
Creation date
4/15/2020 1:25:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0518783
PE
2227
FACILITY_ID
FA0014137
FACILITY_NAME
CENTRAL CALIF TRACTION CO
STREET_NUMBER
1645
STREET_NAME
CHEROKEE
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
11910005
CURRENT_STATUS
01
SITE_LOCATION
1645 CHEROKEE RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2- 55 gallon drums of used oil filters located in Building 1 <br /> 1- 5 gallon bucket of used oil filters located in Building 1 <br /> Close these containers immediately. <br /> 27. 66262.40(a) (CCR) Failed to keep manifest signed copies for 3 years. Retain copies of all <br /> manifests for 3 years. Begin this practice immediately. <br /> 33. 66266.130(b)(5) (CCR) Failed to retain bill of lading for used oil filters. A copy of the receipts <br /> for the disposal of drained used oil filters could not be produced at the time of the inspection. <br /> Retain copies for all used oil filter disposals for 3 years. Begin this practice immediately. <br /> 43. 66265.51(a) (CCR) No contingency plan. A contingency plan must be prepared. A correct and <br /> complete Hazardous Material Management Plan (HMMP)partially fulfills this requirement. A form <br /> outlining the missing information was provided to the owner. Complete this form and post it next to <br /> a telephone in the area that hazardous waste is generated. Correct immediately. <br /> 60. 66266.81(b) (CCR) Damaged lead acid batteries not properly managed and labeled. <br /> 2-damaged lead acid battery were observed on site. <br /> Store all damaged lead acid batteries in a labeled and closed container so that a release to the <br /> environment does not occur. Correct immediately. <br /> 88. 66265.171 (CCR) Condition of Containers. <br /> 4 cardboard boxes of used oil filters located in Building 1 <br /> 2 plastic bags of used oil filters located in Building 1 <br /> Used oil filters were left loosely throughout the facility and stored in containers which caused <br /> disposal to the ground. Product oil was allowed to drain into a 5 gallon bucket that had holes in the <br /> sides. All hazardous waste must be stored in containers which are structurally sound so that leaks <br /> are prevented. Begin this practice immediately. <br /> 88. 66265.174 (CCR) The owner or operator shall inspect areas used for container storage or <br /> transfer at least weekly, looking for leaking containers and for deterioration of containers and the <br /> containment system caused by corrosion or other factors. If a leak or structural weakening is found <br /> you must repackage the hazardous waste so that environmental impact does not occur. Begin this <br /> practice immediately. <br /> 88. 25298(a)(HSC) No person shall abandon an underground storage tank system. Two pipes where <br /> found protruding from the ground on the East side of the property. It appears that an underground <br /> storage tank may be located there. Determine the pipes end point and report the findings to this <br /> office by October 3,2002. <br /> Submit the Certification of Return to Compliance along with a letter stating how each violation was <br /> corrected by October 16, 2002. <br /> This site is subject to re-inspection by this department. <br /> Information regarding hazardous waste compliance school was provided. <br /> a6koInspectorS; Received by <br />
The URL can be used to link to this page
Your browser does not support the video tag.