Laserfiche WebLink
ADJACENT <br />CEASE SPACE <br />9 <br />CODE REVIEW: <br />JURISDICTION: <br />OCCUPANCY TYPE: <br />CONSTRUCTION TYPE: <br />STORIES: <br />FIRE SPRINKLERS: <br />APPLICABLE CODES: <br />CITY OF RIPON <br />B - RESTAURANT <br />VB <br />1 <br />YES <br />2016 C.B.C., C.M.C., C.P.G., G.E.C., C.F.C., TITLE 24, PART 6, <br />2016 CALIFORNIA ENERGY CODE, AND APPLICABLE STATE <br />AND LOCAL REGULATIONS <br />BUILDING AREA: <br />BUILDING AREA (EXISTING / SEPARATE PERMIT): 15,996 SQ. FT. <br />LEASE SPACE (PROJECT AREA: 1,707 SQ. FT. <br />THERE IS NO CHANGE TO ACTUAL BUILDING AREA DUE TO THIS <br />PROJECT <br />ALLOWABLE BUILDING AREA: <br />B OCCUPANCY, FIRE SPRINKLERS (S1), VB TYPE OF CONSTRUCTION: 36,000 SQ. FT, <br />OCCUPANT LOAD: <br />CODE REQUIREMENT <br />LOUNGE: <br />22 <br />BAR (INCLUDING SEATING): <br />15 <br />KITCHEN AREA: <br />1 <br />PREP AREA: <br />1 <br />OFFICE: <br />1 <br />DRY STORAGE: <br />I - EXIT DIRECTLY TO EXTERIOR <br />TOTAL OCCUPANT LOAD <br />41 <br />EXITING: <br />OK <br />EXITS REQUIRED: <br />1 PER C.B.C. TABLE 1006.3.2(2) <br />EXITS PROVIDED: <br />2 <br />EXIT WIDTH CALCULATION: <br />OCCUPANT LOAD: <br />41 <br />41 x 0.2 = <br />8" TOTAL MIN. WIDTH <br />EXIT WIDTH PROVIDED: <br />4. <br />36" DOOR X 2= <br />72" <br />TOTAL = <br />72" > 8" THEREFORE OK <br />MEANS OF EGRESS SUMMARY: <br />CODE DATA PLAN - PATIO <br />SCALE: 114'= F-0" <br />PATIO EXITING: <br />EXITS REQUIRED: <br />EXITS PROVIDED: <br />EXIT WIDTH CALCULATION: <br />OCCUPANT LOAD: <br />10x0.2= <br />EXIT WIDTH PROVIDED: <br />36" GATE"- = <br />1 PER C.B.C. TABLE 1006.3.2(2) <br />1 ('EXIT ONLY' GATE) <br />10 <br />2" TOTAL MIN, WIDTH <br />36"> 9" THEREFORE OK <br />NORTH <br />PLUMBING FIXTURE CALCULATIONS: <br />PER C.P.C. TABLE 422. 1, FOOTNOTE 3, TABLE A, FOOTNOTE AND SECTION 422.2(3) <br />TYPE OF OCCUPANCY PER TABLE 422.1: A-21 RESTAURANT <br />OCCUPANCY GROUP PER TABLE A; A-2 / DINING ROOMS <br />AREA OF LEASE SPACE: 1,707 SQ. FT. <br />EXCLUDED AREAS - PER C.P.C. TABLE A, FOOTNOTE: <br />PER C.P.C. TABLE A, FOOTNOTE, ACCESSORY AREAS ARE EXCLUDED FROM THE <br />SQUARE FOOTAGE FOR THE PURPOSE OF DETERMINING REQUIRED PLUMBING <br />FIXTURES. THE REQUIRED PLUMBING FIXTURE COUNT IS BASED UPON THE <br />FOLLOWING AREAS: <br />LOUNGE: 749 SQ. F. <br />BAR: 191 SQ. F. <br />KITCHEN 110 SQ, F. <br />PREP: 191 SQ. F. <br />OFFICE: 49 SQ. FT. <br />STORAGE: 92 SQ. FT. <br />TOTAL: 1,382 SQ. FT. <br />SQUARE FOOTAGE OF RESTROOMS. CIRCULATION, WALK IN WINE DISPLAY AND <br />EQUIPMENT ARE EXCLUDED FROM FIXTURE COUNT <br />OCCUPANT LOAD FACTOR - FER C.P.C. TABLE A: 30 <br />1,382 SQ. FT. / 30 = 46 <br />46 / 2 = 23 PER GENDER <br />PLUMBING FIXTURE REQUIRED: <br />W/C UR LAV. D.F. <br />MEN 1 - 1 0 <br />WOMEN 1 1 <br />UNISEX 0 0 0 <br />W/C UR� LAV. D. F. <br />MEN 0 - - _ 0 0 <br />WOMEN 1 0 1 - 0 <br />UNISEX 1 2 1 0 R <br />REVISIONS <br />THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />INCORPORATED HEREIN, AS AN INSTRUMENT OF <br />PROFESSIONAL SERVICE, IS THE PROPERTY OF <br />"apt' AND 1S NOT TO BE USED, IN WHOLE OR IN <br />PART, FOR ANY OTHER PROJECT WITHOUT <br />WRITTEN AUTHORIZATION. <br />PLANNING■®■ <br />ARCH I T E C T U R E I�� Aid <br />a 13 <br />ARCHITECTURE PLUS INC. III <br />4335-B NORTH STAR WAY <br />MODESTO, CA 95356 <br />ph. 209.577.4661 <br />fx. 209.577.0213 <br />www.apiarc.com <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />ARCHITECTS <br />In <br />W <br />I -- <br />LU <br />CIlO <br />3C O <br />09 <br />Lujw <br />Z W <br />W <br />Lu <br />!V <br />til <br />N <br />,� I I t I I <br />HALO / <br />\v [ Z <br />,/PREP i ^ O <br />_ :.. 191 SQ. FT. a <br />O.L.F. = 200 S.F. <br />�\..... O.L. = I I Z Z <br />.. FD <br />I�I Q Q <br />i �i <br />.� y_�= <br />'R�STROOM S I a 0 <br />OFD I I I o0 <br />00 <br />01 <br />w/H \ <br />Lu DRY STORAGE ®FEICE <br />p �ARC <br />\.l.F. Q U 92 SQ. FT. fAYEtHr�CcC <br />49 SQ. FT. c�E i <br />= 100 S.F. �.p` F <br />w <br />O.L.F. = 300 S.F. <br />Exir —� W....— . <br />O.L. 1 — — � I C23440 x <br />HB <br />CODE DATA PLAN <br />SCALE: 1/4" = l'-0" <br />n <br />NORTH <br />Anl fifiPYRIAHT gni c) <br />OF C <br />vi - <br />DATE: <br />i -DATE: JANUARY 2019 <br />JOB NO. 18115 <br />DRAWN: T.MARTINEZ <br />CHECKED: J.SMITH <br />SHEET: <br />�I <br />z <br />O <br />0. <br />oc <br />CODE REQUIREMENT <br />PROVIDED <br />1. <br />NUMBER OF EXITS: <br />1 <br />2 <br />OK <br />2. <br />TRAVEL DISTANCE: <br />250 FEET (SPRINKLERED) <br />65 FEET MAX. <br />OK <br />3. <br />COMMON PATH OF TRAVEL: <br />NIA <br />N/A <br />3. <br />DEAD END CORRIDOR: <br />20 FEET MAX. <br />12'-0" MAX. <br />OK <br />4. <br />CORRIDOR WIDTH: <br />N/A <br />N/A <br />- <br />5. <br />SIZE OF EGRESS DOOR: <br />36 INCH MIN. <br />36 INCH MIN. <br />OK <br />6. <br />I <br />STAIR WIDTH: <br />N/A <br />NIA <br />-- <br />CODE DATA PLAN - PATIO <br />SCALE: 114'= F-0" <br />PATIO EXITING: <br />EXITS REQUIRED: <br />EXITS PROVIDED: <br />EXIT WIDTH CALCULATION: <br />OCCUPANT LOAD: <br />10x0.2= <br />EXIT WIDTH PROVIDED: <br />36" GATE"- = <br />1 PER C.B.C. TABLE 1006.3.2(2) <br />1 ('EXIT ONLY' GATE) <br />10 <br />2" TOTAL MIN, WIDTH <br />36"> 9" THEREFORE OK <br />NORTH <br />PLUMBING FIXTURE CALCULATIONS: <br />PER C.P.C. TABLE 422. 1, FOOTNOTE 3, TABLE A, FOOTNOTE AND SECTION 422.2(3) <br />TYPE OF OCCUPANCY PER TABLE 422.1: A-21 RESTAURANT <br />OCCUPANCY GROUP PER TABLE A; A-2 / DINING ROOMS <br />AREA OF LEASE SPACE: 1,707 SQ. FT. <br />EXCLUDED AREAS - PER C.P.C. TABLE A, FOOTNOTE: <br />PER C.P.C. TABLE A, FOOTNOTE, ACCESSORY AREAS ARE EXCLUDED FROM THE <br />SQUARE FOOTAGE FOR THE PURPOSE OF DETERMINING REQUIRED PLUMBING <br />FIXTURES. THE REQUIRED PLUMBING FIXTURE COUNT IS BASED UPON THE <br />FOLLOWING AREAS: <br />LOUNGE: 749 SQ. F. <br />BAR: 191 SQ. F. <br />KITCHEN 110 SQ, F. <br />PREP: 191 SQ. F. <br />OFFICE: 49 SQ. FT. <br />STORAGE: 92 SQ. FT. <br />TOTAL: 1,382 SQ. FT. <br />SQUARE FOOTAGE OF RESTROOMS. CIRCULATION, WALK IN WINE DISPLAY AND <br />EQUIPMENT ARE EXCLUDED FROM FIXTURE COUNT <br />OCCUPANT LOAD FACTOR - FER C.P.C. TABLE A: 30 <br />1,382 SQ. FT. / 30 = 46 <br />46 / 2 = 23 PER GENDER <br />PLUMBING FIXTURE REQUIRED: <br />W/C UR LAV. D.F. <br />MEN 1 - 1 0 <br />WOMEN 1 1 <br />UNISEX 0 0 0 <br />W/C UR� LAV. D. F. <br />MEN 0 - - _ 0 0 <br />WOMEN 1 0 1 - 0 <br />UNISEX 1 2 1 0 R <br />REVISIONS <br />THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />INCORPORATED HEREIN, AS AN INSTRUMENT OF <br />PROFESSIONAL SERVICE, IS THE PROPERTY OF <br />"apt' AND 1S NOT TO BE USED, IN WHOLE OR IN <br />PART, FOR ANY OTHER PROJECT WITHOUT <br />WRITTEN AUTHORIZATION. <br />PLANNING■®■ <br />ARCH I T E C T U R E I�� Aid <br />a 13 <br />ARCHITECTURE PLUS INC. III <br />4335-B NORTH STAR WAY <br />MODESTO, CA 95356 <br />ph. 209.577.4661 <br />fx. 209.577.0213 <br />www.apiarc.com <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />ARCHITECTS <br />In <br />W <br />I -- <br />LU <br />CIlO <br />3C O <br />09 <br />Lujw <br />Z W <br />W <br />Lu <br />!V <br />til <br />N <br />,� I I t I I <br />HALO / <br />\v [ Z <br />,/PREP i ^ O <br />_ :.. 191 SQ. FT. a <br />O.L.F. = 200 S.F. <br />�\..... O.L. = I I Z Z <br />.. FD <br />I�I Q Q <br />i �i <br />.� y_�= <br />'R�STROOM S I a 0 <br />OFD I I I o0 <br />00 <br />01 <br />w/H \ <br />Lu DRY STORAGE ®FEICE <br />p �ARC <br />\.l.F. Q U 92 SQ. FT. fAYEtHr�CcC <br />49 SQ. FT. c�E i <br />= 100 S.F. �.p` F <br />w <br />O.L.F. = 300 S.F. <br />Exir —� W....— . <br />O.L. 1 — — � I C23440 x <br />HB <br />CODE DATA PLAN <br />SCALE: 1/4" = l'-0" <br />n <br />NORTH <br />Anl fifiPYRIAHT gni c) <br />OF C <br />vi - <br />DATE: <br />i -DATE: JANUARY 2019 <br />JOB NO. 18115 <br />DRAWN: T.MARTINEZ <br />CHECKED: J.SMITH <br />SHEET: <br />�I <br />z <br />O <br />0. <br />oc <br />