ADJACENT <br />LEASE SPACE <br />FLOOR PLAN <br />FLOOR AREAS <br />LEASE SPACE: <br />Q <br />ADJACENT <br />LEASE SPACE <br />`77 <br />NORTH <br />PATIO PLAN <br />SCALE: 11,V'= I'-0" <br />y 2 /owS <br />MINIMUM INSULATION <br />REQUIREMENTS <br />EXTERIOR WALLS: R-19 BATT <br />EXTERIOR WALL INSULATION TO BE <br />INSTALLED WITH BUILDING SHELL <br />DEMISING WALL: R-19 BATT <br />ATTIC: R-30 BATT (AT TOP CHORD) <br />ATTIC INSULATION TO BE INSTALLED <br />WITH BUILDING SHELL <br />* VERIFY REQUIREMENTS WITH ENERGY CALCULATONS <br />NOTE: <br />1. ELECTRICAL CIRCUIT BREAKERS SHALL BE LEGIBLY AND DURABLY MARKED. PER CFC <br />605.3.1 <br />2. PROVIDE 2A! 0 -BC WITHIN 75' OF EXITS AND 3,000 S.F. IN GENERAL USE AREAS, FIRE <br />MARSHALL TO DETERMINE LOCATIONS WITH EACH TENANT IMPROVEMENT. <br />3. ALL FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, SMOKE PARTITIONS, AND ANY <br />OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL <br />BE PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING THAT SHALL COMPLY <br />WITH THE FOLLOWING: <br />A. SIGNS OR STENCILING SHALL SHALL BE LOCATED IN ACCESSIBLE <br />CONCEALED FLOOR, FLOOR -CEILING AND ATTIC SPACF..S. <br />B. SIGNS OR STENCILING SHALL B;E LOCATED WITHIN 15 FEET OF THE ENDS <br />OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED <br />HORIZONTALLY ALONG THE WALL OR PARTITION, <br />C. LETTERING SHALL BE NOT LESS THAN 3" IN HEIGHT WITH A MINIMUM <br />STROKE OF 3/8" IN A CONTRASTING COLOR WITH THE WORDING: <br />"FIRE / SMOKE BARRIER - ALL OPENINGS / PENETRATIONS SHALL BE <br />PROTECTED". <br />SYMBOL LEGEND <br />O DOOR SYMBOL -SEE DOOR SCHEDULE SHEET A5 <br />AO WINDOW SYMBOLS - SEE WINDOW SCHEDULE SHEET A5 <br />22 INTERIOR ELEVATION SYMBOL - SEE INTERIOR ELEVATIONS SHEET A4.0 & A4.1 <br />101 ROOM NUMBER - SEE FINISH SCHEDULE A5 <br />FLOOR PLAN KEYNOTES. <br />1. EXTERIOR WALL - EXISTING / SEPARATE PERMIT - PROVIDE R-19 BATT INSULATION FULL <br />HEIGHT OF WALL AS NECESSARY <br />2. EXISTING DEMISING WALL- PROVIDE GYPSUM BOARD AS REQUIRED FOR A COMPLETE <br />ASSEMBLY <br />3. DEMISING WALL - 2 X 6 AT 16" O.C. - PROVIDE R-19 BATT INSULATION FULL HEIGHT OF <br />WALL- PROVIDE 2 X FIRE BLOCKING IN CONCEALED SPACES OF STUD WALLS AND <br />PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT <br />10 FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL PER CBC SECTION 718.2,1 - SEE <br />DETAILS 4 & 6/AD2 <br />4. 2 X 4 STUDS AT 16" O.C. AT INTERIOR WALLS - PROVIDE 2 X FIRE BLOCKING IN <br />CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, <br />AT THE CEILING AND FLOOR LEVELS AND AT 10 FOOT INTERVALS BOTH VERTICAL AND <br />HORIZONTAL PER CBC SECTION 718.2.1 - SEE DETAILS 1, 2 & 6/AD2 <br />5. 2 X 6 STUDS AT 16" O,C. AT INTERIOR WALLS AS INDICATED - PROVIDE 2X FIRE <br />BLOCKING IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING <br />FURRED SPACES, AT THE CEILING LEVEL, AND AT 10'-0" INTERVALS BOTH HORIZONTAL <br />AND VERTICAL PER CBC SECTION 718.2.1 - SEE DETAILS 1, 2 & 6/AD2 <br />6. THICKENED WALL AS INDICATED <br />7. PROVIDE SOUND ATTENUATION BATTS IN WALLS AT ENTIRE PERIMETER OF <br />RESTROOM <br />8. EXISTING POST - TO BE CONCEALED IN NEW DEMISING WALL <br />9. ALIGN WALL WITH FACE OF STUD <br />10. FRAMED OPENING <br />11. PROVIDE BLOCKING IN WALLS FOR WALL MOUNTED SHELVING AND EQUIPMENT - SEE <br />DETAIL 8/AD1 - VERIFY LOCATIONS WITH TENANT <br />12, DIMENSIONS ARE TO FACE OF STUDS - TYPICAL U.N.O. <br />13, DOOR AND FRAME - SEE DOOR SCHEDULE <br />14. STOREFRONT DOOR - EXISTING / SEPARATE PERMIT - VERIFY HARDWARE MEETS <br />ACCESSIBILITY REQUIREMENTS AND REPLACE AS REQUIRED <br />15. STOREFRONT SYSTEM - EXISTING / SEPARATE PERMIT <br />16, STOREFRONT SYSTEM - INSTALL PER MANUFACTURER'S SPECIFICATIONS - SEE <br />STOREFRONT SCHEDULE SHEET AS <br />17, PROVIDE A MINIMUM OF 12" CLEAR AT INTERIOR AT STRIKE SIDE OF <br />OUTSWINGING EXTERIOR DOORS -TYPICAL <br />18. MINIMUM 30" WIDE X 48" DEEP CLEAR FLOOR AREA <br />19. MIN. 60" x 60" CLEAR AND LEVEL LANDING AT EXTERIOR DOORS <br />20, PROVIDE A MINIMUM OF 18" CLEAR AT STRIKE SIDE OF INTERIOR DOORS AND 24" AT <br />EXTERIOR DOORS -SEE DETAIL 13/ADI-TYPICAL <br />21, PROVIDE SIGN ABOVE DOOR TO READ'THIS DOOR TO REMAIN UNLOCKED WHEN THIS <br />SPACE IS OCCUPIED" IF NOT EXISTING PER CBC 1010.1.9.3 ITEM 2 <br />22, INDICATES INTERNATIONAL SIGN OF ACCESSIBILITY (MIN. 6 X 6} - MOUNT ADJACENT <br />TO THE LATCH, OUTSIDE OF THE DOOR, OR ON THE NEAREST ADJACENT WALL OR <br />GLAZING - MOUNTING HEIGHT SHALL BE 60 INCHES ABOVE THE FINISH FLOOR TO THE <br />CENTER LINE OF SIGN - PER CBC 118-703.7.2.1 - SEE DETAIL 10/ADI <br />23, PROVIDE TACTILE EXIT / ROUTE SIGN AT EXIT DOOR AS REQUIRED - SEE DETAIL S/AD1 <br />24. INDICATES INTERIOR WINDOW - SEE DETAILS 7 & 8/AD3 <br />25. CONCRETE WALK - EXISTING / SEPARATE PERMIT <br />26. BUILT-IN CASEWORK WITH COUNTERTOP - VERIFY REQUIREMENTS WITH TENANT <br />27. BUILT-IN BAR - +42" HIGH - VERIFY CONFIGURATION WITH OWNER - PROVIDE <br />COUNTERTOP BRACING PER DETAIL IS/ADI <br />28, KNEE CLEARANCE AT ACCESSIBLE COUNTER SHALL EXTEND 19" DEEP MINIMUM AT 27" <br />ABOVE THE FINISHED FLOOR AND SHALL BE 30" WIDE MINIMUM - SEE DETAIL 12/ADI <br />29. PROVIDE ACCESSIBLE COUNTER - MIN, 60" WIDE AND MAXIMUM 34" A.F.F. - KNEE <br />SPACE TO BE 19" DEEP MINIMUM AT 27" ABOVE THE FINISHED FLOOR AND 30" MINIMUM <br />WIDE - PER CBC I I B-226.3 <br />30. INDICATES TEMPERED GLAZING PER CBC 2406 & 708A.2.1.1 <br />31. PATIO - SEE PATIO PLAN <br />32. FIRE EXTINGUISHER AND CABINET - TYPICAL - VERIFY LOCATIONS WITH FIRE MARSHAL <br />PROVIDE (1) 2A:10BC FIRE EXTINGUISHER EVERY 75WALKING DISTANCE THAT IS NOT <br />MORE THAN 4' FROM THE FLOOR - FIRE EXTINGUISHER TO BE LOCATED NEXT TO MAN <br />DOOR - DISPLAY A CURRENT STATE FIRE MARSHAL SERVICE LABEL PER CFC 1002 <br />33. EQUIPMENT - SEE EQUIPMENT PLAN <br />34- FLOOR SINK - SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS <br />35. MOP SINK - SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS <br />36. HAND SINK - SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS <br />37. EMPLOYEE LOCKERS - MIN 17o LOCKERS TO BE ACCESSIBLE (DENOTED W/ 6" x 6" BLUE <br />STICKER) WITH A MIN REACH HEIGHT OF 9" OR MORE BUT NOT MORE THAN 54" A.F.F. - <br />PROVIDE BACKING AS REQUIRED - MOUNT LOCKERS TO WALL 6" A.F.F. - PROVIDE <br />CONTINUOUS FLOORING AT LOCKER AREA AND COVE UP WALL. MIN. 5" <br />38, ELECTRICAL PANEL - TYPICAL - MAINTAIN CLEAR WORKING AREA - SEE ELECTRICAL <br />DRAWINGS <br />39. WATER HEATER -SEE PLUMBING DRAWINGS <br />40. INDICATES SOFFIT ABOVE -SEE REFLECTED CEILING PLAN <br />41. 1-1 /2" X I-1 /7'X 48° X 20 GA STAINLESS STEEL CORNER GUARD ON OUTSIDE CORNERS <br />- TYPICAL - VERIFY WITH TENANT <br />42. DASHED LINE INDICATES FULL HEIGHT FRP ON PREP / KITCHEN WALLS <br />43. DASHED LINE INDICATES FRP AT JANITORS SINK TO +48" A.F.F. <br />44. FLOOR SURFACES SHALL BE SLIP RESISTANT PER CBC 11 B-302 <br />45. FLOOR TO BE SMOOTH, NONABSORBENT SEALED CONCRETE AND EASILY CLEANABLE <br />46. CUSTOMER SEATING AREA - TABLES (PROVIDED BY OWNER) TO PROVIDE A MINIMUM <br />OF 2 ACCESSIBLE SEATING LOCATIONS PER CBC 11 B-226.1 <br />47. WALL MOUNTED SHELVING - PROVIDED BY TENANT <br />48. DESK AND CHAIR - BY TENANT <br />49. ACCESSIBLE SINGLE -ACCOMMODATION RESTROOM - SEE SHEET A4.1 <br />50. LINE INDICATES APPROXIMATE THICKNESS OF WALL FINISH <br />51. ACCESSIBLE LAVATORY - PROVIDE BRACKETS AND BLOCKING AS NECESSARY FOR <br />SUPPORT - SEE PLUMBING DRAWINGS AND DETAILS 3 & B/ADI <br />52. ACCESSIBLE WATER CLOSETS -SEE PLUMBING DRAWINGS AND DETAIL2/AD1 <br />53. LINE OF AWNING ABOVE - EXISTING / SEPARATE PERMIT <br />54. HOSE BIB - EXISTING / SEPARATE PERMIT <br />55. OUTDOOR CUSTOMER SEATING AREA - TABLE$ (PROVIDED BY OWNER) TO PROVIDE A <br />MINIMUM OF (1) ACCESSIBLE SEATING LOCATIONS PER CBC 11B-226. <br />56, DECORATIVE METAL RAILING AT + 36" HIGH WITH POWDER COAT FINISH - VERIFY <br />CONFIGURATION WITH OWNER - BOLT RAILING TO CONCRETE SLAB WITH (4) 1/4" <br />EXPANSION BOLTS WITH MIN, 3" EMBEDMENT <br />57. FABRICATED METAL PLANTER BOX AT +42" HIGH WITH POWDER COAT FINISH - PROVIDE <br />IRRIGATION AND DRAINAGE TO LANDSCAPE OR TO FACE OF CURB AS OCCURS - <br />VERIFY CONFIGURATION WITH OWNER - SEE DETAILS 13 & 14/AD2 <br />58. FABRICATED METAL PEDESTAL AT +30" WITH POWDER COAT FINISH - SLOPE TOP TO <br />DRAIN <br />59. SAWCUT AND REMOVE EXISTING CONCRETE SLAB FOR NEW WASTE LINES AS <br />NECESSARY - COORDINATE WITH PLUMBING DRAWINGS - SEE DETAIL 7/AD2 <br />60. FLOOR DRAIN - SEE PLUMBING DRAWINGS <br />61. THERMOSTAT - MOUNT AT +44" MAXIMUM - SEE MECHANICAL DRAWINGS <br />62, LIGHTING CONTROL CABINET - SEE ELECTRICAL DRAWINGS <br />63, INDICATES AREA OF NEW 4" REINFORCED CONCRETE SLAB - REINFORCING AND <br />CONTROL JOINTS TO BE SAME AS NOTED IN SHELL BUILDING CONSTRUCTION <br />REVISIONS <br />THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />INCORPORATED HEREIN, AS AN INSTRUMENT OF <br />PROFESSIONAL SERVICE, IS THE PROPERTY OF <br />"api" AND fS NOT TO BE USED, IN WHOLE OR IN <br />PART, FOR ANY OTHER PROJECT WITHOUT <br />WRITTEN AUTHORIZATION. <br />PLANNING ■ ■ ■ <br />ARCHITECTURE <br />WALL LEGEND <br />DOCUMENTS <br />2:X 6 '; <br />64, <br />LOCATION OF WALL BASE TRANSITION - SEE FINISH SCHEDULE <br />Q <br />... <br />65. <br />WINE DISPLAY AREA - EXACT DESIGN BY OTHERS - WALL AND CEILING GYPSUM BOARD <br />O <br />DEMISING WALL <br />TO BE MOISTER RESISTANT - PROVIDE VAPOR BARRIOR AND R-30 INSULATION MIN. - <br />PROVIDE <br />EXISTING DEMISING WALL <br />f _ <br />TEMPERATURE AND MOISTURE CONTROL SYSTEM AS REQUIRED - SEE <br />NOTE: <br />PROVIDER-] 1 SOUND ATTENUATING BATTS AT ALL RESTROOM WALLS <br />MECHANICAL DRAWINGS <br />i fl - <br />66, <br />INDICATES TYPE2 VENT HOOD ABOVE- SEE EQUIPMENT PLAN AND MECHANICAL <br />DRAWINGS <br />67. <br />INDICATES OPEN SHELVING ABOVE - PROVIDE SOLID BLOCKING AS REQUIRED - SEE <br />INTERIOR ELEVATIONS <br />68, <br />INDICATES LOCATIONS OF DECORATIVE WOOD WALL FEATURE - SEE INTERIOR <br />ELEVATIONS <br />69. <br />WALL MOUNTED TV - PROVIDE BLOCKING AS REQUIRED - PROVIDE RECESSED POWER <br />AND CABLE - VERIFY HEIGHT <br />70, <br />FUTURE WALL MOUNTED TV LOCATION - PROVIDE BLOCKING AS REQUIRED - PROVIDE <br />RECESSED POWER AND CABLE - VERIFY HEIGHT <br />71. <br />PROVIDE R 19 INSULATION AT WALL AND R30 INSULATION AT CEILING OF EQUIPMENT <br />ROOM <br />72. <br />INDICATES LOCATION OF WATER FILTRATION SYSTEM - SEE PLUMBING DRAWINGS <br />WALL LEGEND <br />apl COPYRIGHT 2019 <br />ARCHITECTURE PLUS INC. <br />4335-B NORTH STAR WAY <br />MODESTO, CA 95356 <br />ph. 209.577.4661 <br />fx. 209.577.0213 <br />www.apiarc.COTY1 <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />ARCHITECTS <br />Q <br />U <br />CA <br />Lu <br />L <br />O u <br />_O <br />ad <br />W oC <br />Z W <br />j <br />/� <br />L <br />W <br />F- <br />N <br />N <br />DATE: JANUARY 2019 1 <br />JOB NO.: <br />STUD WALL <br />2:X 6 '; <br />2 X 6 STUD WALL <br />CHECKED: <br />2 X 10 STUD WALL <br />SPECIAL INSULATED WALL <br />DEMISING WALL <br />EXISTING DEMISING WALL <br />f _ <br />EXISTING WALL <br />NOTE: <br />PROVIDER-] 1 SOUND ATTENUATING BATTS AT ALL RESTROOM WALLS <br />AND CEILING <br />apl COPYRIGHT 2019 <br />ARCHITECTURE PLUS INC. <br />4335-B NORTH STAR WAY <br />MODESTO, CA 95356 <br />ph. 209.577.4661 <br />fx. 209.577.0213 <br />www.apiarc.COTY1 <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />ARCHITECTS <br />Q <br />U <br />CA <br />Lu <br />L <br />O u <br />_O <br />ad <br />W oC <br />Z W <br />j <br />/� <br />L <br />W <br />F- <br />N <br />N <br />DATE: JANUARY 2019 1 <br />JOB NO.: <br />18115 <br />DRAWN: <br />T.M. / R.H. <br />CHECKED: <br />J.SMITH <br />SHEET - <br />A20 I <br />