ADJACENT
<br />LEASE SPACE
<br />FLOOR PLAN
<br />FLOOR AREAS
<br />LEASE SPACE:
<br />Q
<br />ADJACENT
<br />LEASE SPACE
<br />`77
<br />NORTH
<br />PATIO PLAN
<br />SCALE: 11,V'= I'-0"
<br />y 2 /owS
<br />MINIMUM INSULATION
<br />REQUIREMENTS
<br />EXTERIOR WALLS: R-19 BATT
<br />EXTERIOR WALL INSULATION TO BE
<br />INSTALLED WITH BUILDING SHELL
<br />DEMISING WALL: R-19 BATT
<br />ATTIC: R-30 BATT (AT TOP CHORD)
<br />ATTIC INSULATION TO BE INSTALLED
<br />WITH BUILDING SHELL
<br />* VERIFY REQUIREMENTS WITH ENERGY CALCULATONS
<br />NOTE:
<br />1. ELECTRICAL CIRCUIT BREAKERS SHALL BE LEGIBLY AND DURABLY MARKED. PER CFC
<br />605.3.1
<br />2. PROVIDE 2A! 0 -BC WITHIN 75' OF EXITS AND 3,000 S.F. IN GENERAL USE AREAS, FIRE
<br />MARSHALL TO DETERMINE LOCATIONS WITH EACH TENANT IMPROVEMENT.
<br />3. ALL FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, SMOKE PARTITIONS, AND ANY
<br />OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL
<br />BE PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING THAT SHALL COMPLY
<br />WITH THE FOLLOWING:
<br />A. SIGNS OR STENCILING SHALL SHALL BE LOCATED IN ACCESSIBLE
<br />CONCEALED FLOOR, FLOOR -CEILING AND ATTIC SPACF..S.
<br />B. SIGNS OR STENCILING SHALL B;E LOCATED WITHIN 15 FEET OF THE ENDS
<br />OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED
<br />HORIZONTALLY ALONG THE WALL OR PARTITION,
<br />C. LETTERING SHALL BE NOT LESS THAN 3" IN HEIGHT WITH A MINIMUM
<br />STROKE OF 3/8" IN A CONTRASTING COLOR WITH THE WORDING:
<br />"FIRE / SMOKE BARRIER - ALL OPENINGS / PENETRATIONS SHALL BE
<br />PROTECTED".
<br />SYMBOL LEGEND
<br />O DOOR SYMBOL -SEE DOOR SCHEDULE SHEET A5
<br />AO WINDOW SYMBOLS - SEE WINDOW SCHEDULE SHEET A5
<br />22 INTERIOR ELEVATION SYMBOL - SEE INTERIOR ELEVATIONS SHEET A4.0 & A4.1
<br />101 ROOM NUMBER - SEE FINISH SCHEDULE A5
<br />FLOOR PLAN KEYNOTES.
<br />1. EXTERIOR WALL - EXISTING / SEPARATE PERMIT - PROVIDE R-19 BATT INSULATION FULL
<br />HEIGHT OF WALL AS NECESSARY
<br />2. EXISTING DEMISING WALL- PROVIDE GYPSUM BOARD AS REQUIRED FOR A COMPLETE
<br />ASSEMBLY
<br />3. DEMISING WALL - 2 X 6 AT 16" O.C. - PROVIDE R-19 BATT INSULATION FULL HEIGHT OF
<br />WALL- PROVIDE 2 X FIRE BLOCKING IN CONCEALED SPACES OF STUD WALLS AND
<br />PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT
<br />10 FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL PER CBC SECTION 718.2,1 - SEE
<br />DETAILS 4 & 6/AD2
<br />4. 2 X 4 STUDS AT 16" O.C. AT INTERIOR WALLS - PROVIDE 2 X FIRE BLOCKING IN
<br />CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES,
<br />AT THE CEILING AND FLOOR LEVELS AND AT 10 FOOT INTERVALS BOTH VERTICAL AND
<br />HORIZONTAL PER CBC SECTION 718.2.1 - SEE DETAILS 1, 2 & 6/AD2
<br />5. 2 X 6 STUDS AT 16" O,C. AT INTERIOR WALLS AS INDICATED - PROVIDE 2X FIRE
<br />BLOCKING IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING
<br />FURRED SPACES, AT THE CEILING LEVEL, AND AT 10'-0" INTERVALS BOTH HORIZONTAL
<br />AND VERTICAL PER CBC SECTION 718.2.1 - SEE DETAILS 1, 2 & 6/AD2
<br />6. THICKENED WALL AS INDICATED
<br />7. PROVIDE SOUND ATTENUATION BATTS IN WALLS AT ENTIRE PERIMETER OF
<br />RESTROOM
<br />8. EXISTING POST - TO BE CONCEALED IN NEW DEMISING WALL
<br />9. ALIGN WALL WITH FACE OF STUD
<br />10. FRAMED OPENING
<br />11. PROVIDE BLOCKING IN WALLS FOR WALL MOUNTED SHELVING AND EQUIPMENT - SEE
<br />DETAIL 8/AD1 - VERIFY LOCATIONS WITH TENANT
<br />12, DIMENSIONS ARE TO FACE OF STUDS - TYPICAL U.N.O.
<br />13, DOOR AND FRAME - SEE DOOR SCHEDULE
<br />14. STOREFRONT DOOR - EXISTING / SEPARATE PERMIT - VERIFY HARDWARE MEETS
<br />ACCESSIBILITY REQUIREMENTS AND REPLACE AS REQUIRED
<br />15. STOREFRONT SYSTEM - EXISTING / SEPARATE PERMIT
<br />16, STOREFRONT SYSTEM - INSTALL PER MANUFACTURER'S SPECIFICATIONS - SEE
<br />STOREFRONT SCHEDULE SHEET AS
<br />17, PROVIDE A MINIMUM OF 12" CLEAR AT INTERIOR AT STRIKE SIDE OF
<br />OUTSWINGING EXTERIOR DOORS -TYPICAL
<br />18. MINIMUM 30" WIDE X 48" DEEP CLEAR FLOOR AREA
<br />19. MIN. 60" x 60" CLEAR AND LEVEL LANDING AT EXTERIOR DOORS
<br />20, PROVIDE A MINIMUM OF 18" CLEAR AT STRIKE SIDE OF INTERIOR DOORS AND 24" AT
<br />EXTERIOR DOORS -SEE DETAIL 13/ADI-TYPICAL
<br />21, PROVIDE SIGN ABOVE DOOR TO READ'THIS DOOR TO REMAIN UNLOCKED WHEN THIS
<br />SPACE IS OCCUPIED" IF NOT EXISTING PER CBC 1010.1.9.3 ITEM 2
<br />22, INDICATES INTERNATIONAL SIGN OF ACCESSIBILITY (MIN. 6 X 6} - MOUNT ADJACENT
<br />TO THE LATCH, OUTSIDE OF THE DOOR, OR ON THE NEAREST ADJACENT WALL OR
<br />GLAZING - MOUNTING HEIGHT SHALL BE 60 INCHES ABOVE THE FINISH FLOOR TO THE
<br />CENTER LINE OF SIGN - PER CBC 118-703.7.2.1 - SEE DETAIL 10/ADI
<br />23, PROVIDE TACTILE EXIT / ROUTE SIGN AT EXIT DOOR AS REQUIRED - SEE DETAIL S/AD1
<br />24. INDICATES INTERIOR WINDOW - SEE DETAILS 7 & 8/AD3
<br />25. CONCRETE WALK - EXISTING / SEPARATE PERMIT
<br />26. BUILT-IN CASEWORK WITH COUNTERTOP - VERIFY REQUIREMENTS WITH TENANT
<br />27. BUILT-IN BAR - +42" HIGH - VERIFY CONFIGURATION WITH OWNER - PROVIDE
<br />COUNTERTOP BRACING PER DETAIL IS/ADI
<br />28, KNEE CLEARANCE AT ACCESSIBLE COUNTER SHALL EXTEND 19" DEEP MINIMUM AT 27"
<br />ABOVE THE FINISHED FLOOR AND SHALL BE 30" WIDE MINIMUM - SEE DETAIL 12/ADI
<br />29. PROVIDE ACCESSIBLE COUNTER - MIN, 60" WIDE AND MAXIMUM 34" A.F.F. - KNEE
<br />SPACE TO BE 19" DEEP MINIMUM AT 27" ABOVE THE FINISHED FLOOR AND 30" MINIMUM
<br />WIDE - PER CBC I I B-226.3
<br />30. INDICATES TEMPERED GLAZING PER CBC 2406 & 708A.2.1.1
<br />31. PATIO - SEE PATIO PLAN
<br />32. FIRE EXTINGUISHER AND CABINET - TYPICAL - VERIFY LOCATIONS WITH FIRE MARSHAL
<br />PROVIDE (1) 2A:10BC FIRE EXTINGUISHER EVERY 75WALKING DISTANCE THAT IS NOT
<br />MORE THAN 4' FROM THE FLOOR - FIRE EXTINGUISHER TO BE LOCATED NEXT TO MAN
<br />DOOR - DISPLAY A CURRENT STATE FIRE MARSHAL SERVICE LABEL PER CFC 1002
<br />33. EQUIPMENT - SEE EQUIPMENT PLAN
<br />34- FLOOR SINK - SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS
<br />35. MOP SINK - SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS
<br />36. HAND SINK - SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS
<br />37. EMPLOYEE LOCKERS - MIN 17o LOCKERS TO BE ACCESSIBLE (DENOTED W/ 6" x 6" BLUE
<br />STICKER) WITH A MIN REACH HEIGHT OF 9" OR MORE BUT NOT MORE THAN 54" A.F.F. -
<br />PROVIDE BACKING AS REQUIRED - MOUNT LOCKERS TO WALL 6" A.F.F. - PROVIDE
<br />CONTINUOUS FLOORING AT LOCKER AREA AND COVE UP WALL. MIN. 5"
<br />38, ELECTRICAL PANEL - TYPICAL - MAINTAIN CLEAR WORKING AREA - SEE ELECTRICAL
<br />DRAWINGS
<br />39. WATER HEATER -SEE PLUMBING DRAWINGS
<br />40. INDICATES SOFFIT ABOVE -SEE REFLECTED CEILING PLAN
<br />41. 1-1 /2" X I-1 /7'X 48° X 20 GA STAINLESS STEEL CORNER GUARD ON OUTSIDE CORNERS
<br />- TYPICAL - VERIFY WITH TENANT
<br />42. DASHED LINE INDICATES FULL HEIGHT FRP ON PREP / KITCHEN WALLS
<br />43. DASHED LINE INDICATES FRP AT JANITORS SINK TO +48" A.F.F.
<br />44. FLOOR SURFACES SHALL BE SLIP RESISTANT PER CBC 11 B-302
<br />45. FLOOR TO BE SMOOTH, NONABSORBENT SEALED CONCRETE AND EASILY CLEANABLE
<br />46. CUSTOMER SEATING AREA - TABLES (PROVIDED BY OWNER) TO PROVIDE A MINIMUM
<br />OF 2 ACCESSIBLE SEATING LOCATIONS PER CBC 11 B-226.1
<br />47. WALL MOUNTED SHELVING - PROVIDED BY TENANT
<br />48. DESK AND CHAIR - BY TENANT
<br />49. ACCESSIBLE SINGLE -ACCOMMODATION RESTROOM - SEE SHEET A4.1
<br />50. LINE INDICATES APPROXIMATE THICKNESS OF WALL FINISH
<br />51. ACCESSIBLE LAVATORY - PROVIDE BRACKETS AND BLOCKING AS NECESSARY FOR
<br />SUPPORT - SEE PLUMBING DRAWINGS AND DETAILS 3 & B/ADI
<br />52. ACCESSIBLE WATER CLOSETS -SEE PLUMBING DRAWINGS AND DETAIL2/AD1
<br />53. LINE OF AWNING ABOVE - EXISTING / SEPARATE PERMIT
<br />54. HOSE BIB - EXISTING / SEPARATE PERMIT
<br />55. OUTDOOR CUSTOMER SEATING AREA - TABLE$ (PROVIDED BY OWNER) TO PROVIDE A
<br />MINIMUM OF (1) ACCESSIBLE SEATING LOCATIONS PER CBC 11B-226.
<br />56, DECORATIVE METAL RAILING AT + 36" HIGH WITH POWDER COAT FINISH - VERIFY
<br />CONFIGURATION WITH OWNER - BOLT RAILING TO CONCRETE SLAB WITH (4) 1/4"
<br />EXPANSION BOLTS WITH MIN, 3" EMBEDMENT
<br />57. FABRICATED METAL PLANTER BOX AT +42" HIGH WITH POWDER COAT FINISH - PROVIDE
<br />IRRIGATION AND DRAINAGE TO LANDSCAPE OR TO FACE OF CURB AS OCCURS -
<br />VERIFY CONFIGURATION WITH OWNER - SEE DETAILS 13 & 14/AD2
<br />58. FABRICATED METAL PEDESTAL AT +30" WITH POWDER COAT FINISH - SLOPE TOP TO
<br />DRAIN
<br />59. SAWCUT AND REMOVE EXISTING CONCRETE SLAB FOR NEW WASTE LINES AS
<br />NECESSARY - COORDINATE WITH PLUMBING DRAWINGS - SEE DETAIL 7/AD2
<br />60. FLOOR DRAIN - SEE PLUMBING DRAWINGS
<br />61. THERMOSTAT - MOUNT AT +44" MAXIMUM - SEE MECHANICAL DRAWINGS
<br />62, LIGHTING CONTROL CABINET - SEE ELECTRICAL DRAWINGS
<br />63, INDICATES AREA OF NEW 4" REINFORCED CONCRETE SLAB - REINFORCING AND
<br />CONTROL JOINTS TO BE SAME AS NOTED IN SHELL BUILDING CONSTRUCTION
<br />REVISIONS
<br />THIS DOCUMENT, AND THE IDEAS AND DESIGNS
<br />INCORPORATED HEREIN, AS AN INSTRUMENT OF
<br />PROFESSIONAL SERVICE, IS THE PROPERTY OF
<br />"api" AND fS NOT TO BE USED, IN WHOLE OR IN
<br />PART, FOR ANY OTHER PROJECT WITHOUT
<br />WRITTEN AUTHORIZATION.
<br />PLANNING ■ ■ ■
<br />ARCHITECTURE
<br />WALL LEGEND
<br />DOCUMENTS
<br />2:X 6 ';
<br />64,
<br />LOCATION OF WALL BASE TRANSITION - SEE FINISH SCHEDULE
<br />Q
<br />...
<br />65.
<br />WINE DISPLAY AREA - EXACT DESIGN BY OTHERS - WALL AND CEILING GYPSUM BOARD
<br />O
<br />DEMISING WALL
<br />TO BE MOISTER RESISTANT - PROVIDE VAPOR BARRIOR AND R-30 INSULATION MIN. -
<br />PROVIDE
<br />EXISTING DEMISING WALL
<br />f _
<br />TEMPERATURE AND MOISTURE CONTROL SYSTEM AS REQUIRED - SEE
<br />NOTE:
<br />PROVIDER-] 1 SOUND ATTENUATING BATTS AT ALL RESTROOM WALLS
<br />MECHANICAL DRAWINGS
<br />i fl -
<br />66,
<br />INDICATES TYPE2 VENT HOOD ABOVE- SEE EQUIPMENT PLAN AND MECHANICAL
<br />DRAWINGS
<br />67.
<br />INDICATES OPEN SHELVING ABOVE - PROVIDE SOLID BLOCKING AS REQUIRED - SEE
<br />INTERIOR ELEVATIONS
<br />68,
<br />INDICATES LOCATIONS OF DECORATIVE WOOD WALL FEATURE - SEE INTERIOR
<br />ELEVATIONS
<br />69.
<br />WALL MOUNTED TV - PROVIDE BLOCKING AS REQUIRED - PROVIDE RECESSED POWER
<br />AND CABLE - VERIFY HEIGHT
<br />70,
<br />FUTURE WALL MOUNTED TV LOCATION - PROVIDE BLOCKING AS REQUIRED - PROVIDE
<br />RECESSED POWER AND CABLE - VERIFY HEIGHT
<br />71.
<br />PROVIDE R 19 INSULATION AT WALL AND R30 INSULATION AT CEILING OF EQUIPMENT
<br />ROOM
<br />72.
<br />INDICATES LOCATION OF WATER FILTRATION SYSTEM - SEE PLUMBING DRAWINGS
<br />WALL LEGEND
<br />apl COPYRIGHT 2019
<br />ARCHITECTURE PLUS INC.
<br />4335-B NORTH STAR WAY
<br />MODESTO, CA 95356
<br />ph. 209.577.4661
<br />fx. 209.577.0213
<br />www.apiarc.COTY1
<br />FRANK C. BOOTS
<br />JOSEPH L. SMITH
<br />RODNEY C. ALONZO
<br />ARCHITECTS
<br />Q
<br />U
<br />CA
<br />Lu
<br />L
<br />O u
<br />_O
<br />ad
<br />W oC
<br />Z W
<br />j
<br />/�
<br />L
<br />W
<br />F-
<br />N
<br />N
<br />DATE: JANUARY 2019 1
<br />JOB NO.:
<br />STUD WALL
<br />2:X 6 ';
<br />2 X 6 STUD WALL
<br />CHECKED:
<br />2 X 10 STUD WALL
<br />SPECIAL INSULATED WALL
<br />DEMISING WALL
<br />EXISTING DEMISING WALL
<br />f _
<br />EXISTING WALL
<br />NOTE:
<br />PROVIDER-] 1 SOUND ATTENUATING BATTS AT ALL RESTROOM WALLS
<br />AND CEILING
<br />apl COPYRIGHT 2019
<br />ARCHITECTURE PLUS INC.
<br />4335-B NORTH STAR WAY
<br />MODESTO, CA 95356
<br />ph. 209.577.4661
<br />fx. 209.577.0213
<br />www.apiarc.COTY1
<br />FRANK C. BOOTS
<br />JOSEPH L. SMITH
<br />RODNEY C. ALONZO
<br />ARCHITECTS
<br />Q
<br />U
<br />CA
<br />Lu
<br />L
<br />O u
<br />_O
<br />ad
<br />W oC
<br />Z W
<br />j
<br />/�
<br />L
<br />W
<br />F-
<br />N
<br />N
<br />DATE: JANUARY 2019 1
<br />JOB NO.:
<br />18115
<br />DRAWN:
<br />T.M. / R.H.
<br />CHECKED:
<br />J.SMITH
<br />SHEET -
<br />A20 I