Laserfiche WebLink
0 <br />31 <br />25 <br />I <br />19 <br />rom <br />9 <br />I <br />FLOOR PLAN <br />NORTH <br />i <br />c <br />PATIO PLAN <br />SCALE: 1/4"= 1'-0" <br />MINIMUM INSULATION <br />REQUIREMENTS <br />EXTERIOR WALLS: R-19 BATT <br />EXTERIOR WALL INSULATION TO BE <br />INSTALLED WITH BUILDING SHELL <br />DEMISING WALL: R-19 BATT <br />ATTIC: R-30 BATT IAT TOP CHORD) <br />ATTIC INSULATION TO BE INSTALLED <br />WITH BUILDING SHELL <br />* VERIFY REQUIREMENTS WITH ENERGY CALCULATONS <br />NOTE: <br />I. ELECTRICAL CIRCUIT BREAKERS SHALL BE LEGIBLY AND DURABLY MARKED, PER CFC <br />605.3.1 <br />2. PROVIDE 2A10 -BC WITHIN 750F EXITS AND 3,000 S.F. IN GENERAL USE AREAS, FIRE <br />MARSHALL TO DETERMINE LOCATIONS WITH EACH TENANT IMPROVEMENT. <br />3. ALL FIRE BARRIERS, FIRE PARTITIONS, .SMOKE BARRIERS, SMOKE PARTITIONS, AND ANY <br />OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL <br />BE PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING THAT SHALL COMPLY <br />WITH THE FOLLOWING: <br />A. SIGNS OR STENCILING SHALL SHALL BE LOCATED IN ACCESSIBLE <br />CONCEALED FLOOR, FLOOR -CEILING AND ATTIC SPACES. <br />B. SIGNS OR STENCILING SHALL BE LOCATED WITHIN 15 FEET OF THE ENDS <br />OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED <br />HORIZONTALLY ALONG THE WALL OR PARTITION, <br />C. LETTERING SHALL BE NOT LESS THAN 3" IN HEIGHT WITH A MINIMUM <br />STROKE OF 3/8" IN A CONTRASTING COLOR WITH THE WORDING: <br />"FIRE / SMOKE BARRIER - ALL OPENINGS / PENETRATIONS SHALL BE <br />PROTECTED". <br />SYMBOL LEGEND <br />OI DOOR SYMBOL - SEE DOOR' SCHEDULE SHEET A5 <br />OWINDOW SYMBOLS - SEE WINDOW SCHEDULE SHEET A5 <br />22 INTERIOR ELEVATION SYMBOL - SEE INTERIOR ELEVATIONS SHEET A4.0 & A4.1 <br />i 01 ROOM NUMBER -SEE FINISH SCHEDULE A5 <br />FLOOR PLAN KEYNOTES: i REVISIONS <br />1. <br />EXTERIOR WALL- EXISTING /SEPARATE PERMIT- PROVIDE R-19 BATT INSULATION FULL <br />2 X:5 <br />34. <br />HEIGHT OF WALL AS NECESSARY <br />2 X 10 STUD WALL <br />2. <br />EXISTING DEMISING WALL - PROVIDE GYPSUM BOARD AS REQUIRED FOR A COMPLETE <br />36. <br />ASSEMBLY <br />3. <br />DEMISING WALL - 2 X 6 AT 16' O.C. - PROVIDE R-19 BATT INSULATION FULL HEIGHT OF <br />WALL- PROVIDE 2 X FIRE BLOCKING IN CONCEALED SPACES OF STUD WALLS AND <br />PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT <br />38. <br />10 FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL PER CBC SECTION 718.2.1 - SEE <br />DETAILS 4 & 6/AD2 <br />4, <br />2 X 4 STUDS AT 16" O.C. AT INTERIOR WALLS - PROVIDE 2 X FIRE BLOCKING IN <br />40. <br />CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, <br />41. <br />AT THE CEILING AND FLOOR LEVELS AND AT 10 FOOT INTERVALS BOTH VERTICAL AND <br />HORIZONTAL PER CBC SECTION 718.2.1 - SEE DETAILS 1, 2 & 6/AD2 <br />5. <br />2 X 6 STUDS AT 16" O.C. AT INTERIOR WALLS AS INDICATED - PROVIDE 2X FIRE <br />43. <br />BLOCKING IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING <br />44, <br />FURRED SPACES, AT THE CEILING LEVEL., AND AT 10'-0" INTERVALS BOTH HORIZONTAL <br />45. <br />AND VERTICAL PER CBC SECTION 718.2.1 - SEE DETAILS 1, 2 & 6/AD2 <br />6. <br />THICKENED WALL AS INDICATED <br />7. <br />PROVIDE SOUND ATTENUATION BAITS IN WALLS AT ENTIRE PERIMETER OF <br />48. <br />RESTROOM <br />8. <br />EXISTING POST -TO BE CONCEALED IN NEW DEMISING WALL <br />THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />50, <br />LINE INDICATES APPROXIMATE THICKNESS OF WALL FINISH <br />INCORPORATED HEREIN, AS AN INSTRUMENT OF <br />9, <br />ALIGN WALL WITH FACE OF STUD <br />PROFESSIONAL SERVICE, IS THE PROPERTY OF <br />10. <br />FRAMED OPENING <br />"api" AND IS NOT TO BE USED, IN WHOLE OR IN <br />52. <br />ACCESSIBLE WATER CLOSETS - SEE PLUMBING DRAWINGS AND DETAIL 2/ADI <br />PART, FOR ANY OTHER PROJECT WITHOUT <br />11. <br />PROVIDE BLOCKING IN WALLS FOR WALL MOUNTED SHELVING AND EQUIPMENT - SEE <br />DETAIL 8/AD1 - VERIFY LOCATIONS WITH TENANT <br />WRITTEN AUTHORIZATION. <br />12. <br />DIMENSIONS ARE TO FACE OF STUDS - TYPICAL U.N.O. <br />13, <br />DOOR AND FRAME - SEE DOOR SCHEDULE <br />14, <br />STOREFRONT DOOR - EXISTING / SEPARATE PERMIT - VERIFY HARDWARE MEETS <br />PLANNING ■ ■ ■ <br />ACCESSIBILITY REQUIREMENTS AND REPLACE AS REQUIRED <br />CONFIGURATION WITH OWNER - BOLT RAILING TO CONCRETE SLAB WITH (4) 1/4" <br />ARCHITECTURE <br />15. <br />STOREFRONT SYSTEM - EXISTING / SEPARATE PERMIT <br />FABRICATED METAL. PLANTER BOX AT+42" HIGH WITH POWDER COAT FINISH - PROVIDE <br />16. <br />STOREFRONT SYSTEM - INSTALL PER MANUFACTURER'S SPECIFICATIONS - SEE <br />IRRIGATION AND DRAINAGE TO LANDSCAPE OR TO FACE OF CURB AS OCCURS - <br />STOREFRONT SCHEDULE SHEET AS <br />VERIFY CONFIGURATION WITH OWNER - SEE DETAILS 13 & 14/AD2 <br />17. <br />PROVIDE A MINIMUM OF 12" CLEAR AT INTERIOR AT STRIKE SIDE OF <br />FABRICATED METAL PEDESTAL AT+30" WITH POWDER COAT FINISH - SLOPE TOP TO <br />OUTSWINGING EXTERIOR DOORS -TYPICAL <br />DRAIN <br />18. <br />MINIMUM 30" WIDE X 48" DEEP CLEAR FLOOR AREA <br />AND FOR NEW TE LINESS <br />NEC <br />19, <br />MIN. 60" x 60" CLEAR AND LEVEL LANDING AT EXTERIOR DOORS <br />NECESSARY - COORCUT <br />DINATVE E WITH PLUMBINGEDRAWINGS SEE DEAB <br />TAIL <br />20. <br />PROVIDE A MINIMUM OF 18" CLEAR AT STRIKE SIDE OF INTERIOR DOORS AND 24" AT <br />FLOOR DRAIN - SEE PLUMBING DRAWINGS <br />EXTERIOR DOORS -SEE DETAIL 13/ADI- TYPICAL <br />THERMOSTAT - MOUNT AT +44" MAXIMUM - SEE MECHANICAL DRAWINGS <br />21. <br />PROVIDE SIGN ABOVE DOOR TO READ "THIS DOOR TO REMAIN UNLOCKED WHEN THIS <br />LIGHTING CONTROL CABINET- SEE ELECTRICAL DRAWINGS <br />SPACE IS OCCUPIED" IF NOT EXISTING PER CBG 1010.1.9.3 ITEM 2 <br />INDICATES AREA OF NEW 4" REINFORCED CONCRETE SLAB - REINFORCING AND <br />22. <br />INDICATES INTERNATIONAL SIGN OF ACCESSIBILITY (MIN. 6 X 6) - MOUNT ADJACENT <br />TO THE LATCH, OUTSIDE OF THE DOOR, OR ON THE NEAREST ADJACENT WALL OR <br />CONTROL <br />NTRO JOINTS TO BE SAME AS NOTED IN SHELL BUILDING CONSTRUCTION <br />GLAZING - MOUNTING HEIGHT SHALL BE 60 INCHES ABOVE THE FINISH FLOOR TO THE <br />ARCHITECTURE PLUS INC. <br />Z <br />CENTER LINE OF SIGN - PER CBC I IB -703.7.2.1 - SEE DETAIL 10/ADI <br />4335-B NORTH STAR WAY <br />23. <br />PROVIDE TACTILE EXIT / ROUTE SIGN AT EXIT DOOR AS REQUIRED - SEE DETAIL S/AD1 <br />MODESTO, CA 95356 <br />24. <br />INDICATES INTERIOR WINDOW - SEE DETAILS 7 & 8/AD3 <br />WINE DISPLAY AREA - EXACT DESIGN BY OTHERS - WALL AND CEILING GYPSUM BOARD <br />25, <br />CONCRETE WALK - EXISTING / SEPARATE PERMIT <br />ph. 209.577.4661 <br />26. <br />BUILT-IN CASEWORK WITH COUNTERTOP - VERIFY REQUIREMENTS WITH TENANT <br />fx. 209,577.0213 <br />27. <br />BUILT-IN BAR - +42" HIGH - VERIFY CONFIGURATION WITH OWNER - PROVIDE <br />MECHANICAL DRAWINGS <br />u- a- <br />66. <br />COUNTERTOP BRACING PER DETAIL 1S/AD1 <br />INDICATES TYPE 2 VENT HOOD ABOVE - SEE EQUIPMENT PLAN AND MECHANICAL <br />28, <br />KNEE CLEARANCE AT ACCESSIBLE COUNTER SHALL EXTEND 19" DEEP MINIMUM AT27" <br />www.apiarc.com <br />ABOVE THE FINISHED FLOOR AND SHALL BE 30" WIDE MINIMUM - SEE DETAIL 12/AD1 <br />INDICATES OPEN SHELVING ABOVE - PROVIDE SOLID BLOCKING AS REQUIRED - SEE <br />29. <br />PROVIDE ACCESSIBLE COUNTER - MIN. 60" WIDE AND MAXIMUM 34" A.F.F. - KNEE <br />INTERIOR ELEVATIONS <br />SPACE TO BE 19" DEEP MINIMUM AT 27" ABOVE THE FINISHED FLOOR AND 30" MINIMUM <br />INDICATES LOCATIONS OF DECORATIVE WOOD WALL FEATURE - SEE INTERIOR <br />WIDE - PER CBC 11 11.226.3 <br />ELEVATIONS <br />30. <br />INDICATES TEMPERED GLAZING PER CBC 2406 & 708A.2.1.1 <br />WALL MOUNTED TV - PROVIDE BLOCKING AS REQUIRED - PROVIDE RECESSED POWER <br />31, <br />PATIO - SEE PATIO PLAN <br />AND CABLE - VERIFY HEIGHT <br />70. <br />FRANK C. BOOTS <br />32, <br />FIRE EXTINGUISHER AND CABINET - TYPICAL - VERIFY LOCATIONS WITH FIRE MARSHAL <br />JOSEPH L, SMITH <br />PROVIDE (1) 2A:1 OBC FIRE EXTINGUISHER EVERY 75' WALKING DISTANCE THAT IS NOT <br />PROVIDE R19 INSULATION AT WALL AND R30 INSULATION AT CEILING OF EQUIPMENT <br />MORE THAN 4' FROM THE FLOOR - FIRE EXTINGUISHER TO BE LOCATED NEXT TO MAN <br />RODNEY G ALONZO <br />DOOR - DISPLAY A CURRENT STATE FIRE MARSHAL SERVICE LABEL PER CFC 1002 <br />ARCHITECTS <br />33, <br />EQUIPMENT -SEE EQUIPMENT PLAN <br />2 X:5 <br />34. <br />FLOOR SINK - SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS <br />2 X 10 STUD WALL <br />35. <br />MOP SINK -SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS <br />36. <br />HAND SINK - SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS <br />37. <br />EMPLOYEE LOCKERS - MIN I% LOCKERS TO BE ACCESSIBLE (DENOTED W/ 6" X 6' BLUE <br />STICKER) WITH A MIN REACH HEIGHT OF 9" OR MORE BUT NOT MORE <br />THAN 54" A.F.F. - <br />PROVIDE BACKING AS REQUIRED - MOUNT LOCKERS TO WALL 6" A.F,F. - PROVIDE <br />CONTINUOUS FLOORING AT LOCKER AREA AND COVE UP WALL MIN. 5" <br />38. <br />ELECTRICAL PANEL - TYPICAL - MAINTAIN CLEAR WORKING AREA - SEE ELECTRICAL <br />DRAWINGS <br />39. <br />WATER HEATER - SEE PLUMBING DRAWINGS <br />40. <br />INDICATES SOFFIT ABOVE -SEE REFLECTED CEILING PLAN <br />41. <br />1-1 /2" X 1-1 /2" X 48" X 20 GA STAINLESS STEEL CORNER GUARD ON OUTSIDE CORNERS <br />- TYPICAL - VERIFY WITH TENANT <br />42. <br />DASHED LINE INDICATES FULL HEIGHT FRP ON PREP / KITCHEN WALLS <br />43. <br />DASHED LINE INDICATES FRP AT JANITORS SINK TO +48" A.F.F. <br />44, <br />FLOOR SURFACES SHALL BE SLIP RESISTANT PER CBC 116-302 <br />45. <br />FLOOR TO BE SMOOTH, NONABSORBENT SEALED CONCRETE AND EASILY CLEANABLE <br />46. <br />CUSTOMER SEATING AREA - TABLES (PROVIDED BY OWNER) TO PROVIDE A MINIMUM <br />OF 2 ACCESSIBLE SEATING LOCATIONS PER CBC 11B-226.1 <br />47. <br />WALL MOUNTED SHELVING - PROVIDED BY TENANT <br />48. <br />DESK AND CHAIR - BY TENANT <br />49. <br />ACCESSIBLE SINGLE -ACCOMMODATION RESTROOM - SEE SHEET A4.1 <br />50, <br />LINE INDICATES APPROXIMATE THICKNESS OF WALL FINISH <br />51. <br />ACCESSIBLE LAVATORY - PROVIDE BRACKETS AND BLOCKING AS NECESSARY FOR <br />SUPPORT - SEE PLUMBING DRAWINGS AND DETAILS 3 & 8/ADI <br />52. <br />ACCESSIBLE WATER CLOSETS - SEE PLUMBING DRAWINGS AND DETAIL 2/ADI <br />53. <br />LINE OF AWNING ABOVE - EXISTING / SEPARATE PERMIT <br />54. <br />HOSE BIB - EXISTING / SEPARATE PERMIT <br />55. <br />OUTDOOR CUSTOMER SEATING AREA - TABLESPROVIDED BY OWNER) TO PROVIDE A <br />MINIMUM OF (1) ACCESSIBLE SEATING LOCATIONS PER CBG 118.226.': <br />56. <br />DECORATIVE METAL RAILING AT +36" HIGH WITH POWDER COAT FINISH - VERIFY <br />CONFIGURATION WITH OWNER - BOLT RAILING TO CONCRETE SLAB WITH (4) 1/4" <br />EXPANSION BOLTS WITH MIN. 3" EMBEDMENT <br />57. <br />FABRICATED METAL. PLANTER BOX AT+42" HIGH WITH POWDER COAT FINISH - PROVIDE <br />IRRIGATION AND DRAINAGE TO LANDSCAPE OR TO FACE OF CURB AS OCCURS - <br />VERIFY CONFIGURATION WITH OWNER - SEE DETAILS 13 & 14/AD2 <br />58. <br />FABRICATED METAL PEDESTAL AT+30" WITH POWDER COAT FINISH - SLOPE TOP TO <br />DRAIN <br />59. <br />AND FOR NEW TE LINESS <br />NEC <br />NECESSARY - COORCUT <br />DINATVE E WITH PLUMBINGEDRAWINGS SEE DEAB <br />TAIL <br />60. <br />FLOOR DRAIN - SEE PLUMBING DRAWINGS <br />61. <br />THERMOSTAT - MOUNT AT +44" MAXIMUM - SEE MECHANICAL DRAWINGS <br />62. <br />LIGHTING CONTROL CABINET- SEE ELECTRICAL DRAWINGS <br />63. <br />INDICATES AREA OF NEW 4" REINFORCED CONCRETE SLAB - REINFORCING AND <br />CONTROL <br />NTRO JOINTS TO BE SAME AS NOTED IN SHELL BUILDING CONSTRUCTION <br />DOCUMENTS <br />Z <br />64. <br />LOCATION OF WALL BASE TRANSITION -SEE FINISH SCHEDULE <br />65. <br />WINE DISPLAY AREA - EXACT DESIGN BY OTHERS - WALL AND CEILING GYPSUM BOARD <br />0 0 <br />O <br />TO BE MOISTER RESISTANT - PROVIDE VAPOR BARRIOR AND R-30 INSULATION MIN. - <br />O — <br />PROVIDE TEMPERATURE AND MOISTURE CONTROL SYSTEM AS REQUIRED - SEE <br />MECHANICAL DRAWINGS <br />u- a- <br />66. <br />INDICATES TYPE 2 VENT HOOD ABOVE - SEE EQUIPMENT PLAN AND MECHANICAL <br />DRAWINGS <br />67. <br />INDICATES OPEN SHELVING ABOVE - PROVIDE SOLID BLOCKING AS REQUIRED - SEE <br />INTERIOR ELEVATIONS <br />68. <br />INDICATES LOCATIONS OF DECORATIVE WOOD WALL FEATURE - SEE INTERIOR <br />ELEVATIONS <br />69. <br />WALL MOUNTED TV - PROVIDE BLOCKING AS REQUIRED - PROVIDE RECESSED POWER <br />AND CABLE - VERIFY HEIGHT <br />70. <br />FUTURE WALL MOUNTED TV LOCATION - PROVIDE BLOCKING AS REQUIRED - PROVIDE <br />RECESSED POWER AND CABLE - VERIFY HEIGHT <br />71, <br />PROVIDE R19 INSULATION AT WALL AND R30 INSULATION AT CEILING OF EQUIPMENT <br />ROOM <br />72. <br />INDICATES LOCATION OF WATER FILTRATION SYSTEM - SEE PLUMBING DRAWINGS <br />WALL LEGEND <br />1 <br />STUD WALL <br />2 X:5 <br />2 X 6 STUD WALL <br />2 X 10 <br />2 X 10 STUD WALL <br />SPECIAL INSULATED WALL <br />DEMISING WALL <br />- EXISTING DEMISING WALL <br />EXISTING WALL <br />NOTE: PROVIDE R-11 SOUND ATTENUATING BAITS AT ALL RESTROOM WALLS <br />AND CEILING <br />api COPYRIGHT 2019 <br />m <br />LLJ <br />W .' <br />o� <br />a <br />= O <br />l� <br />W <br />Z W <br />..■. <br />W H <br />W <br />C4 <br />N <br />a <br />U <br />z <br />0 <br />1 DATE: JANUARY 2019 1 <br />I JOB NO,: 18115 1 <br />DRAWN: T.M. / R.H. <br />CHECKED: J.SMITH <br />SHEET <br />A2.1 <br />