Laserfiche WebLink
1 7"CONCRETE SLAB <br /> AT 87.6 LB/OF <br /> 2'-0" <br /> 02 <br /> 37'fi" 2'- <br /> ............. <br /> , <br /> �,.mie <br /> 246 BARS i•3s:;e. '"s E:,ie.•"i??='f:i;:::;z(':,ei`t[ <br /> EACH SIDE OF <br /> MANHOLE 1,a.; <br /> I <br /> t-.. r "--------------------------------- <br /> ------------------------------------------------------------- o a r c i t e C t u r'.e <br /> = --- engineerin <br /> " b' <br /> SUBMERSIBLE I �, <br /> ! L+lB & Associated ,Lfc�. <br /> i 48" FILL/VENT 42"- I 31, <br /> 867 Pacific Street,Suite 120 <br /> PU METER RMP DIAMETER SUMP I I CLEAR <br /> DIAMETER SUMP TYPICAL i San Luis Obispo, CA 93403 <br /> I TYPICAL MIN <br /> 1 I I I TYP. ph 805,544.5240 <br /> fax 805.540.5241 <br /> ! #4 BARS AT www.LHBassoc.com <br /> w I FS <br /> 4 i;,"r, r"ti�j 16"O.C. isl <br /> 2 I p <br /> I { ) _ EACH WAY <br /> I 4'DIA- O I I o <br /> SUMPS m <br /> I z i I F5 3 I1 q?,0V ES 810 <br /> 20,000 GALLON I , f FS-3 �O S $E <br /> I v REGULAR I {' 8,000 Gff��LLON `\ CSF 9� Cy <br /> UNLEADED I PREMUM t2 <br /> ., AAAIIIIII <br /> ! UNLE DED <br /> I <br /> ---- ------ ------ w No. 7891 <br /> I 12,000 DI L N C0 +z <br /> -. E f= <br /> !! O ; I I <br /> i - i o <br /> r� <br /> ----, exp. <br /> NqO <br /> CtV11-OBSERVATI <br /> c� Op GAS-\ <br /> I PER DETAIL 03 FS-5LL RESERVOIR CONTROL POINT <br /> -SPACING PER <br /> BRINE <br /> TYPICAL OF(2) SOILS REPORT RESERVOIR <br /> ! -IF REQUIRED BY LOCAL <br /> I <br /> TANK JURISDICTION CONSULTANTS <br /> I � <br /> I <br /> I 1Q0 1.5' <br /> 11,425# GRAVEL <br /> ! OCOLUMN <br /> 6 I <br /> I � I <br /> ! I <br /> 67'x 1.5'x 36' 5 <br /> DEADMAN ; 2 UNDERGROUND TANK PLAN <br /> I SCALE: 114"=1'-D" <br /> I <br /> I <br /> BUOYANCY CALCULATIONS 24 OOO GALLON TANK) <br /> CALCULATION BASED ON SUBMERGED WEIGHT OF MATERIALS: <br /> "CONTAINMENT SOLUTIONS"TANK WITH SPHERICAL ENDS. <br /> (1D'NOMINAL) <br /> TANK LENGTH:37'-5 112" <br /> TANK DIAMETER: 10'-0" <br /> TRY 36'-0"DEADMAN, EACH SIDE, 18"WIDE x 8"HIGH <br /> REVISIONS <br /> 1 PLAN CHECK#16-3684 <br /> PTY TANK UPLIFT= 19,951 GAL =2,667 GU FT � 07 DECEMBER 2016 <br /> 7-48 GALICF <br /> 2,567 CU FT X 52.4 LBS/CF= 166,436 LBS(DISPLACED WATER) <br /> TANK SUMP UPLIFT=(2)X 3.94 X 2'2 X 4'=100.5 CU FT <br /> 100.5 OF X 62.4 LBS/CU FT=6,271 LBS(DISPLACED WATER) <br /> TOTAL TANK UPLIFT=166,436 LBS+6,271 LBS= 172,707 LBS p <br /> HOLD DOWN CALCULATION <br /> 1, TANK SLAB <br /> 14.0'X42'=341 CU FT <br /> SUBMITTAL DATES <br /> IL <br /> 341 CU FT X 87.6 LBS/CU FT=.29,872 LBS 1 <br /> OWNER: <br /> 2.CUBED BACKFILL ABOVE TANKS _ 03129/2016 <br /> 4'X10.0'X37.5'= 1,500 CU FT-100.5 CU FT= 1,399.5 CU FT 2 1 5 1 7 <br /> 1,399.5 CU FTX 57.6 LBS/CU FT=80,611 LBS � FS-5 1 4 1 6 REG. AGENCIES <br /> 3- CURVED BACKFILL ABOVE TANK FS-5 FS-5 FS-5 FS 5 FS-5 FS-5 <br /> FS-5 FS-5 <br /> 3.14 X 5A'2 X 37.5'=2,943.8 CU FT <br /> 10.0'X10-0'X37.5'=3,750.0 CU FT v OTB . <br /> 3,750.0 CU FT-2,943.8 CU FT=806.2 CU FT=403.1 CU FT A.C. PAVING TANK SLAB - o ¢ Z 24" <br /> 2 <br /> iv [ } �u TYP. -- <br /> 4D3-1 CU FTX 57.6 LBS/CU F7=23,219 LBS) 9FZOFESSIO �' >_ p / \ \ PROJECT NO. <br /> 4. GRAVEL COLUMN ABOVE DEADMEN: �O S B ( <br /> 15-13-001 <br /> 1.5'X14.5'X36.0'X2= 9,566 CU FT <br /> 11566 CU FTX 57.6 LBS/CU FT=.90,202 LBS c� O C ° a q --�� a d d DRAWN BY: <br /> 5. CONCRETE DEADMEN: - � [r Z - a .4 4 a � 4 <br /> No. 78915 � �n - - a a 4 4 a d a. ° <br /> 0.67'X 1.5'X 36,0'=36.2 CU FT � e . 03118 � a � a a AFS <br /> W 2 CU FT X 87.6 LBS/CU FT X(2)=6,342 LBS * * 1"CONDUIT LOOPS TO <br /> 4 - CHECKED BY: <br /> J <br /> 6. DRY WEIGHT OF TANK 11,425 LBS ��T SUMPS <br /> V1� I I I I JRB <br /> TOTAL HOLD DOWN 241,674 LBS j F O� A�,FO I"CONDUIT HOMERUN - <br /> G - TO BUILDING I c I I - <br /> 4"SCH 40 FVC OR FRP I I I I J ° o <br /> TOTAL HOLD DOWN: 241,674 LBS= 1.40 SAFETY FACTOR I I _ <br /> 71 <br /> TOTAL TANK UPLIFT 172,707 LBS - RISER TO GRADE - I I <br /> - <br /> 1I °. ° ° <br /> 4"BLACK STEEL RISER ( <br /> �- SUME MONITOR LIQUID SENSOR I77 I %% + ° o <br /> i o.0 -TYPICAL �� I I I I I I o°°°o °O° -_ =1 <br /> I I I I C°° a°oo __- <br /> I HYDROSTATICDUAL FLOAT I I II I I I I I o o ° d 1 - _ 00 <br /> IMONITOR NG SENSOR O I I I O I I I °O ° o I- Ww L0 <br /> O0 <br /> -� HYDROSTATIC I O I ii I I _ <br /> - °O° ° °°°°° ° ° RESERVOIR I I I I O I o.°° o° ° - I - <br /> 00°°° o °o Z <br /> _ - _ _ _ <br /> LL <br /> EIRACTOR <br /> F TTING E RACTOTTING <br /> F� <br /> TANK LEVEL GAUGE OVERFILL VALVE SET � � TANK LEVEL GAUGE � � - � \\ � O U <br /> ALARM @ 90% ° OVERFILL VALVE ET \ �= I O W <br /> / CAPACITY C 90°/n \ ALARM @ 90% <br /> CAPACITY @ 90% \ CID I— <br /> F4 I_�I = <br /> � a <br /> BACKFILL WITH = o ° ° ° I 12.000 GALLON + S.D00 GALLON 1 I`I <br /> $ o o + DIESEL } PREMIUM �1 4 <br /> PEAGRAVEL AS PER I 11 UNLEADED yl _ <br /> TANK MANUFACTURER .'�o°a° °Q f � ° o <br /> SPECIFICATIONSLEI ` <br /> -TYPICAL STRAIGHT DROP TUBE _ <br /> y STRAIGHT DROP TUBE �- <br /> =1=9 °o ° ' I J °^ - I - <br /> UST INSTALLATION NOTES a° o �� l �J = <br /> ° TRAPPER SCREEN TRAPPER SCREEN / I=I <br /> o°° n \\ TYPICAL TYPICAL I SHEET TITLE <br /> 1. REINFORCE CONCRETE SLAB WITH#4 BARS AT 16"O.C. REINFORCING BARS TO BE NO LESS THAN 2"NO Ell °° ° \ <br /> MORE THAN 4"FROM SURFACE <br /> 6 / / <br /> 2. REINFORCE CONCRETE SLAB AROUND MANHOLE WITH(2)#6 REBAR 60"IN LENGTH EACH SIDE. PLACE aO - � � � / -_ <br /> REBAR 6"FROM SIDES OF MANHOLE. - O ° Z a'ji / 20 000 GALLON <br /> V N <br /> 3- SINGLE 1"CONDUIT 70 EACH SUBMERSIBLE PUMP. PROVIDE SEAL-OFF AT SUMP&BUILDING WIRING � O \ �� DOUBLE WALL <br /> TROUGH. CONTAINS LINE VOLTAGE WIRING. <br /> 4. SINGLE 1"CONDUIT TO EACH TANK. LOOP HOME RUN FROM INTERSTITIAL SENSOR LOCATION TO ° ° ° ° ° ° ° FIBERGLASS <br /> CONTAINMENT SUMP SENSORS AND TANK GAUGES. PROVIDE SEAL-OFF IN BUILDING AND AT TANK, I-I o o°°° O° ° o°°° °° O ° °° ° ° (2)12"x12"x11 GA STEEL ° o °°° o. ° 0°0 0° ° o. o°°°°° w <br /> o °� °O ° ° O °. 0 o°°°° °�° o ° o °O °o ° ° ° 12"x12"x�C SfiF p °°° o <br /> ROUTE TO INTRINSICALLY SAFE TROUGH IN BUILDING. CONTAINS ONLY LOW VOLTAGE WIRING FOR ° °o ° ° O °O O �°°° ° o°° o STRIKER PLATES BY �}} ° ° �°° 0 O I@I PV g p o , o.00 '.'. <br /> ° o° ° ° TANK INSTAL L <br /> SENSORS. ° ° TANK MANUFACTURER TANK SHALL BE SET LEVE1! O °� °° ° TK'MANl1f� 11 <br /> ACTb1R° ° �° ° '- <br /> J� _ - <br /> _ _ - - - _ - m <br /> 5. USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN 118"&MAX OF 314"IN SIZE, � ° DET <br /> _ _ _ _ _ _ - _ _ _ - _ - AILS <br /> FREE OF - <br /> CLAY, SLAG,CINDERS,OR DEBRIS,ALL SUBSTITUTES MUST BE APPROVED BY MANUFACTURER'S - I � - <br /> AND OWNERS FIELD REPRESENTATIVE. � -- - <br /> 0 <br /> I =i I-I I-; - - - -f I-I - - - - - - �I = <br /> 6. 7 - I � �-� II_ - I I - v <br /> TANK PAD MINIMUM 2'-0"OFF OUTSIDE WALLS OF TANKS,AND MUST COVER THE FOOTPRINT OF THE - - - -~ =�� I - -j i:_-_ �_ - - -I S <br /> TANKS. REQUIRED TO PROVIDE FOR PROPER TANK HOLD DOWN,AND TO PREVENT ACCIDENTAL DRILLING I <br /> INTO TANK. �I I I- I i- I I- I - I IE �� o <br /> (4)12"x12"x11GA STEEL STRIKETYPICR PLATES - I -_ <br /> {4) 12"x12"x11GA STEEL STRIKER PLATES -I -� <br /> AL UNDER OPENINGS WITH MANWAYS BY ° SHEET NO. <br /> 7. CUT CORNER WHERE MEETING ASPHALT PAVING ONLY. SQUARE CORNERS WHERE MEETING CONCRETE. TANK MANUFACTURER <br /> TYPICAL UNDER OPENINGS WITH MANWAYS BY <br /> 2'-0"MIN, TANK MANUFACTURER END OF TANK <br /> 8. REFER TO SITE SPECIFIC PLANS FOR ACTUAL PIPE RUNS AND NUMBER OF PRODUCT LINES. EXCAVATION TANK SIZE VARIES WTW MANUFACTURER AND MODEL NUMBER <br /> 9. 7-0"MIN, o <br /> ONLY 7 <br /> EXCAVATION r FS THF PROPOSED FUEL STORAGE SYSTEM SHALL BEA XERXES SYSTEM(OR APPROVED EQUAL)WITH , ONLY � <br /> DOUBLE WALL,TURBINE ENCLOSURE, FIBERGLASS HYDROSTATIC TANK WITH LEAK DETECTION <br /> -3 <br /> SENSORS,AND MEET OR EXCEED ALL CALIFORNIA TITLE 23 AND CUPA REQUIREMENTS. <br /> m <br /> SCALE: 112°=1'-0" <br />