Laserfiche WebLink
UST INSTALLATION NOTES 1 7"CONCRETE SLAB <br /> AT 87.6 LB/CF <br /> 1. REINFORCE CONCRETE SLAB WITH#4 BARS AT 16"O.C. REINFORCING BARgc;ei, va.va, <br /> S TO BE NO LESS THAN 2"NO <br /> MORE THAN 4"FROM SURFACE- gal .:=F`x- 6a I s;:E° Ella el i <br /> 2. REINFORCE CONCRETE SLAB AROUND MANHOLE WITH(2)#6 REBAR 60"IN LENGTH EACH SIDE. PLACE <br /> REBAR 6"FROM SIDES OF MANHOLE- <br /> 3. SINGLE 1"CONDUIT TO EACH SUBMERSIBLE PUMP. PROVIDE SEAL-OFF AT SUMP&BUILDING WIRING <br /> TROUGH.CONTAINS LINE VOLTAGE WIRING. = ° . <br /> ' •u° .. <br /> g 00 <br /> 4. SINGLE 1"CONDUIT TO EACH TANK. LOOP HOME RUN FROM INTERSTITIAL SENSOR LOCATION TO <br /> ¢g"e°e@°°°a6eege,,a.:e"%S�! 4gm:«$�"='J:i;c:i;-{;•;ii-Er'. <br /> CONTAINMENT SUMP SENSORS AND TANK GAUGES- PROVIDE SEAL-OFF IN BUILDING AND AT TANK. <br /> architecture <br /> UTE TO INTRINSICALLY SAFE TROUGH IN BUILDING.CONTAINS ONLY LOW VOLTAGE WIRING FOR <br /> e n g i n e e r i n g <br /> SENSORS. <br /> 5. USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN 118"&MAX OF 314"IN SIZE, <br /> 1-+lB & Associ,,+es, .Ltd. <br /> EE OF CLAY,SLAG, CINDERS, OR DEBRIS.ALL SUBSTITUTES MUST BE APPROVED BY MANUFACTURER'S <br /> AND OWNERS FIELD REPRESENTATIVE. 867 Pacific Street,Suite 120 <br /> San Luis Obispo,CA 93401 <br /> 6. TANK PAD ph 805.540.5240 <br /> MINIMUM 2'-0"OFF OUTSIDE WALLS OF TANKS,AND MUST COVER THE FOOTPRINT OF THE I BUOYANCY CALCULATIONS(20,000 GALLON TANK) <br /> fax 805.540.5241 <br /> soc.co <br /> www.LHBassoc.com <br /> cam <br /> TANKS. REQUIRED TO PROVIDE FOR PROPER TANK HOLD DOWN,AND TO PREVENT ACCIDENTAL DRILLING I I - " <br /> INTO TANK. ljL CALCULATION BASED ON SUBMERGED WEIGHT OF MATERIALS: <br /> I— "CONTAINMENT SOLUTIONS"TANK WITH SPHERICAL ENDS- <br /> 7. CUT CORNER WHERE MEETING ASPHALT PAVING ONLY.SQUARE CORNERS WHERE MEETING CONCRETE. w (10'NOMINAL) <br /> 2 I o TANK LENGTH: 3T-5 112" <br /> >- TANK DIAMETER: 10'-0" O P�OFESS�Ok9 <br /> 8. REFER TO SITE SPECIFIC PLANS FOR ACTUAL PIPE RUNS AND NUMBER OF PRODUCT LINES- 4' b5' <br /> \ TRY 36'-0"DFADMAN, EACH SIDE, 18"WIDE x 8"HIGH , S $S < <br /> SUMPS I m �� _q <br /> 9. THE PROPOSED FUEL STORAGE SYSTEM SHALL BE A XERXES SYSTEM(OR APPROVED EQUAL)WITH i I z EMPTY TANK UPLIFT- - 19,951 GAL =2,667 CU FT � � 4 � <br /> DOUBLE WALL,TURBINE ENCLOSURE, FIBERGLASS HYDROSTATIC TANK WITH LEAK DETECTION 7,48 GALICF <br /> O cr Z <br /> SENSORS,AND MEET OR EXCEED ALL CALIFORNIA TITLE 23 AND CUPA REQUIREMENTS. I 2,667 CU FT X 62.4 LBS/CF- 166,436 LBS(DISPLACED WATER) No.78916 - <br /> I <br /> 2 * exp. 03118 <br /> TANK SUMP UPLIFT=(2)X 3 14 X 2' X 4'= 100.5 CU FT <br /> NqT Gl V 4 F�\� <br /> 100.5 CF X 62 4 LBSI CU FT=6,271 LBS(DISPLACED WATER)= OF CAO= TOTAL TANK UPLIFT= 166,436 LBS+6,271 LBS= 172 7�07 LBS f <br /> I I <br /> HOLD DOWN CALCULATION <br /> I I <br /> i 1 TANK SLAB : CONSULTANTS <br /> I <br /> .58'X 14-fl'X 42'=341 CU FT <br /> 341 CU FT X 87 6 LBSI CU FT=29,872 LBS <br /> TANK 2. CUBED BACKFILL ABOVE TANKS <br /> 1010 4'X 10.0'X 37-5'= 1,500 CU FT-100,5 CU FT= 1,399.5 CU FT <br /> 9'750# GF2A FL 1,399.5 CU FT X 57.6 LBSI CU FT=80,611 LBS I <br /> COLUMN 3. CURVED BACKFILL ABOVE TANK <br /> i O I <br /> \4 3.14X5.0'2X375'=2,9438 CU FT <br /> 10-0'X 10,0'X 37.5'=3,750.0 CU FT <br /> .67'x 1.5'x 36' S I 3,750,0 CU FT-2,943.8 CU FT=806,2 CU FT=403-1 CU FT <br /> QEADMAN I I 2 FESS/ <br /> 403.1 CU FT X 57.6 LBSI CU FT=23,219 LBS) QfLO O <br /> J 4.GRAVEL COLUMN ABOVE DEADMEN: (�� S 8S � <br /> I 1-5'X 14,5'X 36.0'X 2- 1,566 CU FT <br /> 1,566 CU FT X 57-6 LBSI CU FT=90,202 LBS v� <br /> 5. CONCRETE DEADMEN: w X No. 78916 <br /> 0.67'X1.5'X36,0'=36.2 CU FT K e . 03118 ' <br /> 36.2 CU FT X 87.6 LBSI CU FT X(2)=6,342 LBS <br /> 6, DRY WEIGHT OF TANK: 9,750 LBS L 01 <br /> Cf <br /> TOTAL HOLD DOWN 239.999 LBS 1 9TF OF C0 <br /> TOTAL HOLD DOWN: 239,999 LBS=1.39 SAFETY FACTOR <br /> TOTAL TANK UPLIFT: 172,707 LBS <br /> REVISIONS <br /> 1 PLAN CHECK#16-3684 <br /> 07 DECEMBER 2016 <br /> SUBMITTAL DATES <br /> OWNER: <br /> 2 1 4 03/29/2016 <br /> FS-5 FS-5 FS-5 6 REG, AGENCIES <br /> FS-5 FS-5 <br /> 0.T.B. <br /> A.C. PAVING TANK SLAB iE: < z 24" <br /> N a TYP. - <br /> \ PROJECT NO, <br /> 15-13-001 <br /> DRAWN BY. <br /> V 4 da G. 44. <br /> d 4 � AFS <br /> a d. <br /> 4 <br /> _- <br /> I"CONDUIT LOOPS TO 40, CHECKED BY: <br /> e - <br /> SUMPs (ra ° JRB <br /> 1"CONDUIT HOMERUN I o I O O O o O o <br /> - TO BUILDING f <br /> - 4"SCH 40 PVC OR FRP o <br /> RISER TOGRADE <br /> o \°° ° 0 0 o°V° O <br /> it I Q o ° <br /> - 0 4"BLACK STEEL RISER O I II ° $o Q o. Q °o a a01 <br /> 0° ° <br /> -= So O MONITOR LIQUID SENSOR <br /> TYPICAL f O O ° o°° 0 0 0° \ <br /> - o DUAL FLOAT � I I I ° ° � - <br /> _ _ o o. I ° o ° F m <br /> _ DUAL FLOAT ! W Ln <br /> ° HYDROSTATIC O °o°° ° HYDROSTATIC °O ° W � <br /> I EI I- o°°° MONITORING SENSOR I ° °o-° MONITORING SENSOR o 0 o e° o ° ° ° ° - <br /> _ HYDROSTATIC O I o 0 o a° - i <br /> RESERVOIR _y� o - - O ° o o°°' o - - <br /> - -- - 0 Z <br /> NO z <br /> TT NG EIRACTOFF\\ =o o - j U <br /> /\ TANK LEVEL GAUGE - - \\ <br /> 0 U <br /> ALARM�90% O <br /> CAPACITY OVERFILL VALVE SET O L <br /> @90/ 0.) <br /> I <br /> I I \ Z <br /> _ 1 <br /> BACKFILL WITH o 0 20,000 GALLON y <br /> PEAGRAVEL AS PER a °° y _ _ <br /> REGULAR l ° o - <br /> TANK MANUFACTURER •'�o°°°° °� I I UNLEADED E <br /> SPECIFICATIONS - <br /> ° <br /> TYPICAL \ o°°0 4 STRAIGHT DROP TUBE <br /> i I °0 <br /> TRAPPER SCREEN ' <br /> TYPICAL , , a <br /> SHEET TITLE <br /> LLa <br /> ° ° o �\ = z <br /> ° �/ - 20,000 GALLON <br /> o ��= -- - - - N <br /> ° <br /> _ - - <br /> DOUBLE IWLSA <br /> LL 1 I W° FIBERGLASS <br /> o. OO ° <br /> oDo°° O . ° ° ° <br /> a0 o° o 0 o 0 12x12xdG� STEK b 0° ° <br /> QO '� °� 0 °TANK SHALL BE SET LEVEL TANKINSTALLT �MANFACT E°° °0 ° ° <br /> _ <br /> 1 - - <br /> -iI= - _ _ - - - - _ _ - _ <br /> �� - - - _- - <br /> - I I _ - = I=III_ __ __ \ 11=1 I ==_-= -_ I Imo' 2 <br /> aj <br /> (4)12"x12"x11GA STEEL STRIKER PLATES-/ <br /> TYPICAL UNDER OPENINGS WITH MANWAYS BY <br /> TANK MANUFACTURER SHEET NO. <br /> END OF TANK <br /> 2 0 MEN. <br /> EXCAVATION TANK SIZE VARIES WITH MANUFACTURER AND MODEL NUMBER 2'4"MIN, � <br /> _ <br /> ONLY EXCAVATION o FS-4 <br /> ONLY u <br /> i� <br />