i <br />Q_J <br />G✓ <br />w �- <br />07 U <br />MZ) <br />UJ <br />�O <br />o~ <br />IL <br />CL <br />D <br />J Q <br />Q J <br />'0¢� <br />:) L V) <br />zcy <br />U0 <br />aX�N <br />uiw <br />0- <br />V) <br />NOT USED <br />NO SCALE <br />CONNECT TO SUPPORTING CONNECT TO SUPPORTING <br />STRUCTURAL MEMBER STRUCTURAL MEMBER <br />TRANSVERSE �� 1/2" CLEA NCE <br />BRACE MAXIMUM \DD VERTICAL Hi�LONGITUDINALONE EACH SII <br />�3 i10 <br />MAXIMUM CLEARANCE <br />/-- HORIZONTAL BRACE <br />.IJ <br />DUCT SIZE <br />ACCESS HOLE <br />Lel <br />2 <br />N <br />ROOF WITH METHOD <br />cn <br />ACCESS COVER - 16 GAUGE <br />M <br />U <br />4 <br />0 <br />ROOF CURB (COORDINATE <br />0 <br />FIRST LAYER FIRE BARRIER DUCT WRAP CUT SAME <br />I BOLTS EQUAL <br />OF ANGLES N <br />V) <br />1 " TYPICAL <br />4 SIDES <br />m T T <br />INSULATION WHERE REQUIRED <br />NOTES: <br />1. CABLE BRACES MAY BE USED FOR SEISMIC RESTRAINT IN LIEU OF ANGLE BRACES. <br />CENTER SEISMIC BRACING <br />NO SCALE <br />1 <br />ACCESS HOLE <br />VENTED ROOF CURB. SEE <br />2 <br />1/4 IN. (6mm) DIAMETER ALL THREADED RODS <br />ROOF WITH METHOD <br />3 <br />ACCESS COVER - 16 GAUGE <br />o <br />4 <br />INSULATED PINS - WELDED <br />ROOF CURB (COORDINATE <br />5 <br />FIRST LAYER FIRE BARRIER DUCT WRAP CUT SAME <br />SIZE AS COVER <br />6 <br />SECOND LAYER FIRE BARRIER DUCT WRAP WITH 1 <br />OVERLAP ON ALL SIDES <br />IN. (25mm) <br />7 <br />THIRD LAYER FIRE BARRIER DUCT WRAP WITH 1 IN. <br />OVERLAP ON ALL SIDES OF PREVIOUS LAYER <br />(25mm) <br />8 <br />SPEED CLIPS <br />u <br />9 <br />ALUMINUM TAPE COVERING ALL EXPOSED EDGES <br />GREASE DUCT CLEANOUT. <br />10 <br />SPOOL PIECES FOR THREADED RODS <br />CONNECT DUCT TO CURB <br />11 <br />1/4 IN. (6mm) DIAMETER WING NUTS <br />SIZE PER CURB <br />FOR REFERENCE ONLY. INSTALL PER MANUFACTURERS <br />RECOMMENDATIONS. <br />GREASE DUCT CLEANOUT AC <br />NO SCALE <br />01 <br />�Q <br />e <br />il <br />WELD OR SOLDER <br />WATERTIGHT ALL <br />DUCT ABOVE ROOF <br />CURB CAP <br />ROOF DECK WITH <br />BUILT ---UP ROOFING; <br />EXTEND TO TOP <br />OF CURB <br />CURB FASTENING <br />FLANGE <br />NO USED <br />NO SCALE <br />CONNECT TO SUPPORTING CONNECT TO SUPPORTING <br />STRUCTURAL MEMBER STRUCTURAL MEMBER <br />c� <br />z <br />LONGITUDICt <br />NAL <br />0 DUCT SIZE CABLE BRACE <br />LONGITUDINAL <br />v=i w CABLE BRACE <br />TRANSVERSE <br />CABLE BRACE <br />l <br />TRANSVERSE BRACE <br />2 M, <br />1 M <br />PLATE <br />WASHEF <br />SHEET METAL STRAP <br />(MIN 2-1/2"x12 GA. STP. <br />LONGITUDINAL <br />BRACES <br />1 4" MAX I 3" LONG ANGLE <br />/ PLATE WASHER <br />TRANSVERSE HANGER LONGITUDINAL HANGER <br />A BRACING DETAIL NCALE <br />CING DETAIL <br />NO SCALE <br />DOUBLE HANGER SEISMIC CABLE <br />BRACING FOR ROUND DUCTS UP TO 84" <br />NO SCALE <br />FIRE RATED WALL <br />MIN. 4 LB DENSITY MINERAL WOOL OR <br />EQUIV. COMPRESSED PACKING <br />MATERIAL. PROVIDE 2000+ SILICONE <br />SEALANT BOTH SIDES OF WALL. <br />10.5" 3" 3" MINIMUM PERIMETER AND <br />LTI OVERLAP EACH <br />LAYERAYER 21 AT 21 ON CENTER <br />-TWO LAYERS OF 3M, 615+ FIRE <br />GREASE DUCT <br />BARRIER DUCT WRAP. BANDING <br />OVERLAP INSTALLATION SHOWN. <br />ALTERNATIVE OVERLAP METHOD <br />AND FULL PINNING IN LIEU OF <br />BANDING IS ACCEPTABLE. COMPLY <br />WITH MANUFACTURER'S WRITTEN <br />INSTALLATION INSTRUCTIONS. <br />ANGLE IRON HANGER WITH ALL -THREAD <br />ROD TO UPPER ATTACHMENT. SPACING, <br />ANGLE THICKNESS, AND ROD DIAMETER <br />PER DUCT SUPPORT SPECIFICATIONS. <br />STAINLESS STEEL BANDING MINIMUM 1/2" WIDE <br />AND 0.015" THICK, AT 10.5" ON CENTER. DO <br />NOT DAMAGE WRAP OR SCRIM FOIL FACING. <br />FOR DUCTS 24" AND LARGER IN WIDTH, PROVIDE 12 GA. <br />COPPER COATED STEEL INSULATION PINS WITH GALV. <br />STEEL SPEED CLIPS, 1-1/2" DIAMETER, ON BOTTOM OF <br />HORIZONTAL DUCTS AND SIDES OF VERTICAL RISERS. <br />SPACE PINS 10-1/2" ON CENTER 80TH DIRECTIONS. <br />GREASE DUCT FIRE WRAP INSULATION <br />O INSTALLATION DETAIL <br />NO SCALE <br />1 <br />I z_ I <br />I � I <br />I 0 <br />F <br />INSULATION AS REQUIRED <br />SECURE DUCT TO CURB <br />WITH SCREWS 12" ON <br />CENTER ALL AROUND <br />ACOUSTICAL LINING <br />FASTEN INTO WOOD <br />NAILER. <br />ROOF CURB <br />SECURE CURB TOII <br />r <br />VENTED ROOF CURB. SEE <br />GALVANIZED <br />--ROOF SEE <br />ROOF WITH METHOD <br />COVER <br />zm <br />o <br />STRUCTURE <br />CONSISTENT WITH <br />ROOF CURB (COORDINATE <br />II <br />� Q <br />ARCHITECTURAL AND <br />ROOF CONSTRUCTION <br />LL_- <br />JJ <br />DISCONNECT <br />STRUCTURAL PLANS <br />m <br />SWITCH <br />- - - - <br />u <br />FOR DETAILS <br />ROOF OPENING AND <br />GREASE DUCT CLEANOUT. <br />AND CURB <br />TYPE 1 HOOD, UL <br />CONNECT DUCT TO CURB <br />SEE SHEET H1. <br />SIZE PER CURB <br />-3" HOOD STANDOFF. <br />SEE NOTE 7 <br />MANUFACTURER'S <br />EXTEND ACOUSTICAL LINER <br />APPROVED DRAWINGS <br />-GREASE DRAIN WITH <br />FIRST 10' FROM FAN OR <br />-INCANDESCENT <br />AS OTHERWISE SPECIFIED <br />NOTES; <br />1. SPUD BACK GRAVEL A MINIMUM <br />OF 30" IN ALL DIRECTIONS. FLASH WITH 90# <br />MINERAL FACED BASED FLASHING. <br />STRIP WITH THREE <br />LAYERS OF ROOFING FELT <br />EMBEDDED IN HOT ASPHALT. GRAVEL TO MATCH. <br />RECTANGULAR <br />AIR DUCT <br />r-1 <br />z PENETRATION <br />THROUGH�ROOF <br />DETAIL <br />NO SCALE <br />1/4" THREADED ROD TO <br />STRUCTURE <br />ELECTRICAL <br />WIRING BY EXHAUST DUCT <br />ELECTRICAL RE: MECHANICAL PLAN <br />CONTRACTOR r <br />BACKDRAFT <br />FAN HOUSING DAMPER <br />DAMPER <br />L --FLEX CONNECTOR <br />EXHAUST GRILLE CEILING <br />PROVIDED WITH <br />EXHAUST FAN <br />CEILING MOUNTED EXHAUST FAN SUPPORT <br />,1+11111110*90.113 <br />ROOF KITCHEN EXHAUST <br />FAN, KEF-1 & KEF-2 <br />SLOPE HORIZONTAL DUCT 1/4" PER FOOT <br />ROOF CLEANOUT <br />MAKEUP AIR DUCT <br />VOLUME °0 <br />DAMPER (TYP) <br />CEILING <br />l <br />CEILING ACCESS PANEL <br />MAKE --UP AIR SUPPLY DIFFUSER___) <br />6"MIN. <br />PROVIDE 1" THICK, R-6 FIBERGLASS INSULATION <br />METALLIC OR NON-METALLIC <br />BAND(TYPICAL)TO COMPLETELY COVER DIFFUSER CONE WHERE <br />SCHEDULED OR SPECIFIED. <br />CEILING DIFFUSER WITH VOLUME <br />DAMPER AS SCHEDULED SEISMIC BRACING <br />(Trp) <br />s <br />CEILING <br />NOTES: <br />1. EXTEND RIGID METAL DUCT SO THAT MAXIMUM FLEXIBLE DUCT LENGTH DOES NOT <br />EXCEED 5'-0". PROVIDE RIGID 90' ELBOW WHERE REQUIRED TO KEEP FLEXIBLE <br />DUCT WITHIN 5'-0" LENGTH LIMITATION. <br />4 LAY --IN TYPE CEILING DIFFUSER DETAIL <br />NO SCALE <br />EXHAUST FAN <br />WITH BIRDSCREEN <br />INSTALL NON -VENTED <br />CURB EXTENSION IF ZERO <br />CLEARANCE FIRE -RATED <br />WRAP IS UTILIZED, VENTED <br />CURB EXTENSION IF A <br />FIRE -RATED <br />NON-COMBUSTIBLE <br />ENCLOSRE IS <br />CONSTRUCTED <br />GREASE TRAP <br />INSTALL NEOPRENE <br />GASKET BETWEEN <br />DUCT AND FAN-` <br />PREFABRICATED <br />INSULATED CURB WITH <br />TREATED WOOD NAILER <br />ROOF INSULATION <br />OVERSIZED <br />r <br />VENTED ROOF CURB. SEE <br />GALVANIZED <br />Ca <br />� <br />COVER <br />zm <br />o <br />6" <br />z <br />ROOF CURB (COORDINATE <br />WEATHERPROOF <br />� Q <br />USI <br />(NEMA 3R) <br />z <br />m <br />DISCONNECT <br />coo <br />m <br />SWITCH <br />-, <br />u <br />FAN BASE HINGE <br />w <br />GREASE DUCT CLEANOUT. <br />OVERSIZED <br />o <br />VENTED ROOF CURB. SEE <br />GALVANIZED <br />DETAIL #8 THIS; SHEET. <br />o <br />COVER <br />g <br />x <br />6" <br />z <br />ROOF CURB (COORDINATE <br />zLLJ <br />� Q <br />USI <br />- TWO PIECE <br />SUPPLIER <br />> <br />GALVANIZED <br />coo <br />m <br />COUNTER <br />-, <br />u <br />FLASHING <br />w <br />GREASE DUCT CLEANOUT. <br />AND CURB <br />TYPE 1 HOOD, UL <br />LISTED, <br />ROOF DECK REFER TO ",--WELDED EXHAUST DUCT. SEE <br />ARCHITECTURAL DRAWINGS PLANS FOR SIZE AND <br />LOCATION. INSTALL ZERO <br />CLEARANCE FIRE -RATED WRAP <br />OR CONSTRUCT A FIRE -RATED <br />NON-COMBUSTIBLE ENCLOSURE. <br />UPBLAST GREASE EXHAUST FAN DETAIL <br />ING <br />ENT <br />FLOOR I l_ _-__- - SEE EQUIPMENTMLIST <br />NQTES: l I <br />1. SUBMIT SHOP DRAWINGS OF ALL HOOD SYSTEMS TO CITY FOR APPROVAL PRIOR TO <br />INSTALLATION. <br />2. TOTAL HOOD SYSTEM TO BE IN COMPLETE CONFORMANCE WITH NFPA, AND ALL LOCAL <br />CODES AND REGULATIONS. <br />3. COORDINATE ALL ANSUL FIRE PROTECTION SYSTEMS WITH FIRE PROTECTION CONTRACTOR <br />WHO SHALL ALSO BE RESPONSIBLE FOR ALL PERMITS AND TESTING REQUIRED. <br />4. PROVIDE WRAP SYSTEM WHERE APPROVED BY LOCAL CODES IN LIEU OF RATED ENCLOSURE <br />5. PROVIDE ACCESS PANELS AS REQUIRED BY LOCAL CODE. <br />6. HOODS SHALL EXTEND MINIMUM 6" BEYOND ALL OPEN SIDES AND FRONT EDGE OF FOOD <br />COOKING EQUIPMENT BEING SERVED. <br />NO SCALE <br />T <br />0 <br />E <br />C*? <br />O may- C=>U <br />04 l(j <br />0 d' O <br />00 <br />Q- d r7? <br />>- Lu uL. <br />LuLU <br />u? <br />0 V N c <br />LLI 000 <br />V_ d' <br />c=1 <br />M <br />0 <br />V <br />W cn <br />THIS DRAWING IS AN INSTRUMENT OF <br />SERVICE AND AS SUCH SHALL REMAIN <br />THE PROPERTY OF NEPTUNE DESIGN <br />GROUP I.I.G. UNAUTHORIZED USE OF <br />REPRODUCTION WITHOUT PERMISSION <br />OF THE ARCHITECT IS PROHIBITED. THIS <br />DRAWING IS ONLY FOR USE IN <br />CONNECTION WITH THIS PROJECT AND <br />SHALL NOT BE USED FOR OTHER <br />LOCATIONS. COPYRIGHT 2018. <br />VENTED ROOF CURB. SEE <br />DETAIL #8 THIS; SHEET. <br />TRANSITION GREASE <br />EXHAUST DUCTS TO <br />6" <br />o <br />ROOF CURB (COORDINATE <br />zLLJ <br />°iW <br />SIZE WITH ROOF CURB <br />SUPPLIER <br />ROOF JOIST <br />GREASE EXHAUST DUCT <br />-----2-HR <br />FIRE WRAP, SEE <br />u <br />DETAIL #10 THIS SHEET. <br />GREASE DUCT CLEANOUT. <br />-(HOOD #1 & HOOD #2) SEE DETAIL #9 THIS SHEET. <br />TYPE 1 HOOD, UL <br />LISTED, <br />SEE SHEET H1. <br />= <br />(Ji <br />-3" HOOD STANDOFF. <br />SEE NOTE 7 <br />-FLAME-GUARD SPARK <br />ARRESTOR GREASE <br />FILTERS <br />-GREASE DRAIN WITH <br />REMOVABLE CUP <br />-INCANDESCENT <br />EXHAUST HOOD <br />� <br />LIGHTS <br />ING <br />ENT <br />FLOOR I l_ _-__- - SEE EQUIPMENTMLIST <br />NQTES: l I <br />1. SUBMIT SHOP DRAWINGS OF ALL HOOD SYSTEMS TO CITY FOR APPROVAL PRIOR TO <br />INSTALLATION. <br />2. TOTAL HOOD SYSTEM TO BE IN COMPLETE CONFORMANCE WITH NFPA, AND ALL LOCAL <br />CODES AND REGULATIONS. <br />3. COORDINATE ALL ANSUL FIRE PROTECTION SYSTEMS WITH FIRE PROTECTION CONTRACTOR <br />WHO SHALL ALSO BE RESPONSIBLE FOR ALL PERMITS AND TESTING REQUIRED. <br />4. PROVIDE WRAP SYSTEM WHERE APPROVED BY LOCAL CODES IN LIEU OF RATED ENCLOSURE <br />5. PROVIDE ACCESS PANELS AS REQUIRED BY LOCAL CODE. <br />6. HOODS SHALL EXTEND MINIMUM 6" BEYOND ALL OPEN SIDES AND FRONT EDGE OF FOOD <br />COOKING EQUIPMENT BEING SERVED. <br />NO SCALE <br />T <br />0 <br />E <br />C*? <br />O may- C=>U <br />04 l(j <br />0 d' O <br />00 <br />Q- d r7? <br />>- Lu uL. <br />LuLU <br />u? <br />0 V N c <br />LLI 000 <br />V_ d' <br />c=1 <br />M <br />0 <br />V <br />W cn <br />THIS DRAWING IS AN INSTRUMENT OF <br />SERVICE AND AS SUCH SHALL REMAIN <br />THE PROPERTY OF NEPTUNE DESIGN <br />GROUP I.I.G. UNAUTHORIZED USE OF <br />REPRODUCTION WITHOUT PERMISSION <br />OF THE ARCHITECT IS PROHIBITED. THIS <br />DRAWING IS ONLY FOR USE IN <br />CONNECTION WITH THIS PROJECT AND <br />SHALL NOT BE USED FOR OTHER <br />LOCATIONS. COPYRIGHT 2018. <br />REVISION <br />Q <br />DATE: 3.23.2018 <br />REVIEW SET <br />NOT FOR <br />PERMIT <br />MECHANICAL <br />DETAILS <br />I>Y <br />u. j <br />o <br />zLLJ <br />°iW <br />U <br />z <br />� <br />w <br />u <br />CL`nLnn� <br />U <br />oL6w <br />= <br />(Ji <br />in <br />Q <br />W <br />oCLo <br />0 <br />� <br />d' <br />r-1 <br />Q <br />o <br />0 <br />0 <br />d <br />d <br />0 <br />REVISION <br />Q <br />DATE: 3.23.2018 <br />REVIEW SET <br />NOT FOR <br />PERMIT <br />MECHANICAL <br />DETAILS <br />