My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
6970
>
2300 - Underground Storage Tank Program
>
PR0231833
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2024 2:53:51 PM
Creation date
4/27/2020 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0231833
PE
2361
FACILITY_ID
FA0003874
FACILITY_NAME
Meineke Car Care Center # 4130
STREET_NUMBER
6970
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
02
SITE_LOCATION
6970 WEST LN STE 130
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231833_6970 WEST_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
477
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications <br />Seste, Model X76S <br />Power. 115 VAC, 60Hz <br />Power Consumption: 100 VA <br />Operating Temperature: 32 to 165®F (0 to 75°C) <br />Dimensions: 9x9.5x4.2 in. (22.86x24.I3xI0.67 cm) <br />Mounting: General purpose area: wall mount <br />e'*� Approved: File I.I. 2N4AI.AX <br />Nw000l <br />Annunciator Module <br />Field Sensor: Dry contact <br />Field Sensor Voltage: 115 VAC (supplied by X76S) <br />Number of inputs: One per module <br />°» Approved: File I.I. 2N4AI.AX <br />Intrinsically Safe Field Sensor <br />Interface Module X53 <br />Number of inputs: Two per module <br />Sensors Voltage: 24 VDC, current limited <br />Sensors: Dry contact <br />Output Interface to Alarm Module: Relay contact; <br />normally open/normally closed; selectable <br />Power Consumption: 750 mW per input <br />Supply Voltage: 24 VDC from IS power supply <br /><:•»> Approved: File I.I. 2N4AI.AX <br />Power Supply IS (Intrinsically Safe) <br />Power Input: 115 VAC <br />Output Voltage: 24 VDC <br /><,ZApproved: File ),I. 2N4AI.AX <br />Vapor Sensor, Model HV <br />Detection Method: Solid-state diffusion type <br />Detectable Gases: Hydrocarbons, gasoline, solvents, <br />carbon monoxide. methane, ammonia, sulfur dioxide, <br />hydrogen sulfide <br />Detectable Range: 0-100% LEL <br />Accuracy: ±5% <br />Response Time: Less than 15 sec. to 90% full scale <br />Sensitivity: 5 ppm <br />Sensor Life: 5 years minimum <br />Zero Drift: Less than 5% per year <br />Operating Temperature: -400 to 165°F (-400 to 75°C) <br />Electrical Classification: Class 1, Division 1, Groups B, C <br />and D-. hazardous atmosphere <br />Cable Length: 25 feet; 3 -conductor, number 20 AWG <br />shielded; max. length 3.000 feet <br />0. Approved: File E100826 <br />Prc=rc.- 50 psi maximum <br />Leads: 22 AWG <br />Approved: File E86797 <br />Tank Leak Sensor. Model IS -7 For fiberglass tank <br />Housing Material: ABS <br />Mounting: %" NPT with %" THD and lock nut <br />Pressure: 150 psig at 70°F (21 °C) maximum <br />Liquid SpG: .70 minimum <br />Switch: <br />Type: Single pole, single throw N.C. <br />Rat&W: 10 VA. 110 to 240 VAC <br />Leads. 22 AWG <br />Approved: File E86797 <br />Reservoir T)W T�tnk Leak Serwr, Model LS -11 <br />Reservoir: <br />Volume: Two gallons (7.57 liters) <br />Dimensions (he(ghtx nidth x depth): <br />13xIIxII inches (33.02x27.94x27-94 cm) <br />Afaterial.. Polyethylene plastic <br />Switch: <br />W.- Single pole, single throw <br />RatirT.- 10 VA. 110 to 240 VAC <br />Stem and flan material: Polysulfone <br />QperariV Temperature. 0 to 2250F <br />(-18 to 1070C) <br />Pressure: 50 psi maximum <br />Leads. 22 AWG <br />(D Approved: File E86797 <br />The Ronan Model X765 Leak Detector Monitor System <br />can be configured to meet the different local and state <br />codes for underground storage by proper selection of <br />sensors and monitor modules. For example, a particular <br />local code and/or type of facility may require leak detection <br />of a tank annulus. The monitor system would consist of the <br />following items. <br />Model X76SJ <br />L- No. of alarm inputs (I thru 4) max -4 <br />Accessories <br />Qty. Type <br />LS -3 (Vertical liquid level sensing probe) <br />LS -7 (Horizontal liquid level sensing probe) <br />LS -10 (Reservoir liquid level system) <br />HV Vapor Sensor (Specify product <br />being monitored) <br />Tank Leak, Sensor, Model L5-3 warranty: Ronan warrants equipment of its own manufacture to be <br />Housing: 304 stainless steel free from defects in material and workmanship under normal conditions <br />of use and service. and will repair of replace any component round to be <br />Switch: defective. on its return. transportation charges prepaid. within one year <br />Type: Single pole. single throw N.C. of it., original purchase. This warranty carries no liability. either <br />Ratir(g: 10 VA. 110 to 240 VAC expressed or implied. beyond our obligation to replace the unit which <br />Stein and float material: Fuel -proof polysulfone carries the warranty. <br />RONAN ENGINEERING <br />LIMITED <br />3.' Pennondc) Road <br />Toronto. Ontario <br />Canada M41%IZ5 <br />(4161 752 .03 10 *Telex 6311562 <br />FAX (416) 752-8072 <br />RONAN ENGINEERING <br />(RUST.) PTY. LTD. <br />Unit to. s Leighton rime <br />= N.SAV 2077 <br />(02) 477.7344 *Telex 75467 <br />FAX (02) 477-6151 <br />ranted in U.S A <br />RONAN ENGINEERING <br />RONAN ENGINEERING <br />T1 <br />RONAN COMPANY <br />LTD. U.K. <br />r.o. Box 1275 <br />1 Tilley Road <br />212tV Oxnard Street <br />Crowther District 3 <br />%%oodland Hills. <br />Washington. Lyne and Wear <br />'' <br />California 91.,67 U.S.A. <br />United Kingdom. NI.3S-CIEA <br />(818) 883-5211 *Telex 698-490 <br />(NI) 416.IM9 e Telex 537-746 <br />FAX (818) 992-6435 <br />FAX (091) 416-5856 <br />x rt611286 <br />RONAN ENGINEERING <br />LIMITED <br />3.' Pennondc) Road <br />Toronto. Ontario <br />Canada M41%IZ5 <br />(4161 752 .03 10 *Telex 6311562 <br />FAX (416) 752-8072 <br />RONAN ENGINEERING <br />(RUST.) PTY. LTD. <br />Unit to. s Leighton rime <br />= N.SAV 2077 <br />(02) 477.7344 *Telex 75467 <br />FAX (02) 477-6151 <br />ranted in U.S A <br />
The URL can be used to link to this page
Your browser does not support the video tag.