Laserfiche WebLink
• <br />• <br />C <br />4. Type A Sensors. <br />Connect the two marked or color -coded wires from each <br />sensor to the appropriate terminals on the Type A <br />Interface Module connector (see Figure 16, "Type A <br />Interface Mode Wiring Diagram"). Be sure to main- <br />tain the proper polarity between the sensor wires <br />and their respective module connector terminals. <br />SENSOR + I T T' T"TSTGT'T8 1 MAXIMUM SERSUR <br />OUiPUi RAi1NGS: <br />G VGC <br />IS AMP <br />0 TYPE A INT E MODULE O <br />MODULE <br />OOoOOOmooOoOOooO <br />CONNECTOR <br />RIGID 7 <br />CONDUIT MONITOR <br />UP TOS <br />SENSORS <br />SENSOR SENSOR SENSOR <br />nI .2 AS <br />Figure 16. Type A Interface Module Wiring Diagram <br />Type B Sensors. <br />Connect the three marked or color -coded wires from each <br />sensor to the appropriate terminals on the Type B <br />Interface Module connector (see Figure 17, "Type B <br />Interface Module Wirng Diagram"). Be sure to main- <br />tain the proper polarity between the sensor wires <br />and their respective module connector terminals. <br />SENSOR <br />J 0 <br />TYPE 0INT EMODULE <br />MODULE <br />000 0 0 0 00 000000000 0 CONNECTOR <br />MONITOR <br />RIGID UPTo6 <br />CONDUIT SENSORS <br />S \I/ SENSOR <br />sE' <br />..1 r.2soRs <br />Figure 17. Type B Interface Module Wiring Diagram. <br />Site Preparation a9Wnstallation Instructions <br />TLS -1W UST Monitoring System <br />F4 <br />TLS -350 Relay Output Modules incorporate four Form -C <br />relay outputs, and the UO Combination Modules incorpo- <br />rate two. These relays may be connected to external <br />systems or devices that do not draw more than 2A. <br />IMPORTANT! ONCE OUTPUT RELAYS HAVE BEEN <br />CONNECTED TO EXTERNAL DEVICES AND THE <br />SYSTEM HAS BEEN STARTED AND PRO- <br />GRAMMED, MODULE POSITIONS, CONNECTOR <br />POSITIONS AND WIRE POSITIONS CANNOT BE <br />CHANGED WITHOUT REPROGRAMMING THE <br />SYSTEM! <br />IMPROPER SYSTEM OPERATION WILL RESULT <br />IF ANYONE OF THESE POSITIONS IS CHANGED <br />WITHOUT REPROGRAMMING. <br />,r �t <br />•� �: 1 <br />IS r # <br />0 <br />Be sure to accurately record on the circuit directory the <br />type of module and the location of each device wired to the <br />connector. <br />Identify each connector with a self-adhesive number label <br />according to the slot number. <br />DO NOT CONNECT OUTPUT RELAYS TO A DE- <br />VICE THAT DRAWS MORE THAN 2 AMPS! <br />Output Power: Output Relay Contact, Resistive Load - <br />120 VAC, 2A Max.; or 24 VDC, 2A Max. <br />1. Connect the wires (#14 AWG) from each external device <br />to the appropriate terminals on the output module (see <br />Figure 18, "Relay Output Module Wiring Diagram," or <br />Figure 19, "1/0 Combination Module Wiring Diagram"). <br />Figure 18. Relay Output Module Wiring Diagram. <br />19 <br />RELAY NG�x0�CTZNGZT tYiOU CTpGAN0at1 <br />• <br />RELAY RAiIHGG <br />Form CContav'Is <br />1z24YWE <br />O <br />2A Mev <br />4 -RELAY T MODULE <br />'l <br />MODULE <br />CONNECTOR <br />;0 1O O O O O O OOO O O <br />I I I <br />� I I <br />II II <br />II II <br />I I I I <br />I <br />RIGID <br />I I I <br />ii II <br />II it <br />I I <br />MONITOR <br />CONDUIT <br />i ' UP TO a I I <br />EXTERNAL —I 1 <br />DEVICES <br />I I I I <br />NC NO C NC NO C <br />\I/ \I/ <br />EXTERNAL EXTERNAL <br />DEVICE DEVICE <br />Figure 18. Relay Output Module Wiring Diagram. <br />19 <br />