Laserfiche WebLink
LINE LEAIDDETECTOR (LLD) TEe' REPORT <br />TEST DATE: May 26, 2009 <br />A1. FACILITY <br />A2. OWNER <br />Name <br />Quik Stop Market #132 <br />San Joaquin County Environmental Health <br />Name <br />Quik Stop Markets, Inc. <br />Address <br />3555 W. Hammer Lane, Stockton, CA 95219 <br />600 E. Main Street, Stockton, CA 95202 <br />Address <br />4567 Enterprise Street, Fremont, CA 94538 <br />Phone # <br />510-657-8500 <br />May 18, 2009 <br />Phone # <br />510-85741500 <br />Contact <br />Michael Karvelot <br />Garrett Backus <br />Contest <br />Michael Karvelot <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />1 <br />Name <br />Walton Engineering, Inc. <br />Address <br />600 E. Main Street, Stockton, CA 95202 <br />Gasoline .87 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />May 18, 2009 <br />MLLD <br />UC # <br />617238 A. B, Haz <br />Inspector <br />Garrett Backus <br />VMI 99LD-2000 <br />Contact <br />Richard Walton <br />Phone # <br />209-468-3439 <br />7031208 <br />Phone # <br />916.825.3203 <br />I. MECHANICAL LINE LEAK DETECTOR TEST RESULTS <br />Tact FAidnmant llQw1- Vaeerkma VMI I nT-SLQn <br />J. COMMENTS: <br />" la.� WALTON <br />Signature: ENGINEERING, INC. <br />Technician: Jessie Wadkins t B35391 530788"T <br />Date: May 26, 2009 <br />Tank number <br />1 <br />2 <br />3 <br />Product contained <br />Gasoline .87 <br />Gasoline - 89 <br />Gasoline - 91 <br />Leak Detector Type <br />MLLD <br />MLLD <br />MLLD <br />Leak detector make/model <br />VMI 99LD-2000 <br />VMI 99LD-2000 <br />FE Petro STP -MLD <br />Serial number <br />7031208 <br />7031338 <br />1080379 <br />Functional Element Holding (psi) <br />25 <br />26 <br />25 <br />Resiliency (ml) <br />90 <br />80 <br />125 <br />Test leak rate (gph) <br />3.00 <br />3.00 <br />3.00 <br />Pump pressure (psi) <br />25 <br />26 <br />25 j <br />Metering pressure (psi) <br />13 <br />14 <br />9 <br />Pressure Restriction Reduction (psi) <br />12 <br />12 <br />16 <br />Length of Restriction Test (seconds) <br />30 <br />30 <br />30 <br />Full Flow Opening time (seconds) <br />7 <br />5 <br />5 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Tank number <br />Product contained <br />--------------- <br />( Leak Detector Type <br />Leak detector makelmodel <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml) <br />Test leak nate (gph) <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />J. COMMENTS: <br />" la.� WALTON <br />Signature: ENGINEERING, INC. <br />Technician: Jessie Wadkins t B35391 530788"T <br />Date: May 26, 2009 <br />