My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
515
>
2300 - Underground Storage Tank Program
>
PR0231400
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
4/27/2020 12:24:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231400
PE
2361
FACILITY_ID
FA0003539
FACILITY_NAME
S B GAS & MARKET
STREET_NUMBER
515
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23309031
CURRENT_STATUS
01
SITE_LOCATION
515 W ELEVENTH ST STE 301
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231400_515 W ELEVENTH_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IL <br /> San Joaquin County low <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> S B GAS & MARKET 515 W ELEVENTH ST, TRACY Jul 15, 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plan did not list the corrosion <br /> protection, UDC construction and indicate if your UST have striker plates for all three tanks. The monitoring plan must <br /> be uploaded to the California Environmental Reporting System(CERS). Immediately log into CERS, make the <br /> necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted and/or uploaded onto CERS. A site plan must be submitted <br /> identifying the locations where monitoring will be performed. Immediately log into the California Environmental <br /> Reporting System (CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on July 29, <br /> 2014 and a test report was submitted on September 10, 2014, 1 month late. A copy of the test report must be <br /> submitted within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test reports <br /> are performed in a timely manner. <br /> This is a minor violation. <br /> 125 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on July 29, 2014 and an inspection report was issued identifying information to be <br /> submitted to bring this site into compliance. This information was required to be submitted by August 28, 2014. <br /> Although this facility submitted a return to compliance on August 28, 2014, it was not completed. The required <br /> documents to be uploaded on CERS was incomplee, resulting in a non-compliant status for this facility. An operator <br /> that receives an inspection report shall have 30 days to submit a written response that includes a statement <br /> documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a written <br /> response documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection <br /> report. <br /> This is a Class II violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): I CINDY VO, EH Specialist (209)468-8257 07/15/2015 <br /> Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.