Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> WIRONMENTAL HEALTH DEPARTMENT <br /> 304 East Weber Avenue,3`d Floor,Stockton,CA 95202-2708 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sijzov.orjz/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Insp]ec�tion Date: <br /> Facility, rev r UST# <br /> Product CN\ Dom. <br /> Facility Contact: Title: Phone: <br /> ti sv�,G <br /> Monitoring Panel: Piing system: 0 fill prevention: <br /> L7 Pressurized !Suction El Gravity LKM chanical ❑Audibleh isual <br /> XI tion type: V' lations: <br /> oeutine L�'Monitoring Certification El Installation El Other: MI-RDetect El M2-RPrev LJ M-3 Both <br /> VIOLATION(S) HSC=Califomia Health&Safety Code;CCR=California Code of Regulations V R <br /> # Code Section <br /> V=Violation;RV=Re eat Violation V <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 & c Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 c (2)(D) Monitoring&response plan is current and filed with the local agency <br /> 6 CCR 2712(i Monitorin &response plan is onsite <br /> 7 CCR 2712 b) Maintenance&monitoring records (Ml) <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January, 1, 1984) <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present (M1) <br /> 11 CCR 2630(d) UST system monitoring equipment is properly located to detect a leak (MI) <br /> 12 HSC 25291 b UST system monitoring equipment isoperational M2) <br /> 13 CCR 2636 1 Continuous monitoring system for underground piping&UDC is present M1) <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636(c)(1) All releases in secondary piping flow to a collection sum <br /> 17 HSC 25291 ( Line leak detectors are installed Ml <br /> 18 CCR 2635(b)(1) Spill container (M2) <br /> 19 CCR 2635 (2) Overfill prevention system (M2 <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&21 containment <br /> 21 HSC 25291 (e) Water in 2°containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases Ml <br /> 23 CCR 2715 Designated Operator:(a)Statement from UST owner; (c-e)Monthly inspection;( Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test (Ml) <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636( 4 Annual line tightness test (M1) <br /> 28 CCR 2661 (f) Repair for tank/piping has had tightness test (M2) <br /> 29 CCR 2643 e Biennial tightness test of gravity pipingre-Janus 1, 1984) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping(pre-January 1, 1984) (Mi) <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> 34 HSC 25298 Permit to temporarily close UST system <br /> 35 HSC 25298 c Permit to close UST system <br /> -36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298 a) Illegal abandonment of UST system <br /> 38 Other: <br /> HD INSP OR: PHONE: UIC <br /> Se tic stem: <br /> SiOterves>_20 people/day <br /> E TITLE: 0 Receives other than sanitary waste <br /> Other disposal methods: <br /> ❑Dry wells/French Drains <br /> EHD 23-02-002 <br />