Laserfiche WebLink
(916) 464-4680 <br /> >>> "Vicki McCartney [EH] " <vmccartney@sjcehd.com> 12/14/2006 9:20 AM <br /> Amy, <br /> I did review the work plan and I noticed that I have a slightly different address for <br /> Ripon Farm Services. It is 932, instead of 938 Frontage Road. <br /> Genesis Engineering & Development (Genesis) did not provide specific information <br /> concerning the construction of the deep well using conductor casing. Please have Genesis <br /> provide a cross section and an overhead view of the proposed deep well that includes <br /> dimensions for the casings. <br /> San Joaquin County (SJC) requires that monitoring wells be constructed following the "Well <br /> Standards" in accordance with SJC Ordinance Code Section 9-1115.6. Genesis can access the <br /> "Well Standards" by going to SJC Environmental Health Department's (EHD) website <br /> http://www.sjgov.org/ehd, Applications and Forms, and select "Well Standards" . Section <br /> 13 .9.2 of the "Well Standards" specifically states that the monitoring well borehole <br /> diameter shall be at least four inches greater than the outside diameter of the conductor <br /> casing. The inner diameter of the permanent conductor casing shall in turn be at least <br /> four inches greater than the outside diameter of the well casing. <br /> (These same requirements can be found in "California Well Standards" . ) Because this work <br /> plan does not give specifics as to the inside and outside diameters of the conductor <br /> casing, I can not determine whether this work plan meets these requirements. <br /> Once the work plan has been approved, Genesis can proceed with getting access agreements, <br /> encroachment permits, and then submit boring permit applications and fees to SJCEHD for <br /> the well installations. <br /> Please do not hesitate to contact me if you have any questions. Thanks, Amy. <br /> Vicki McCartney, Senior REHS <br /> San Joaquin County <br /> Environmental Health Department <br /> 304 E. Weber Avenue <br /> Stockton, CA 95202-2708 <br /> Phone: (209) 468-3456 <br /> Fax: (209) 468-3433 <br /> E-mail: vmccartney@sjcehd.com <br /> -----Original Message----- <br /> From: Amy Terrell [mailto:aterrell@waterboards.ca.gov] <br /> Sent: Wednesday, December 13, 2006 9:12 AM <br /> To: Vicki McCartney [EH] <br /> Cc: Harlin Knoll [EH] <br /> Subject: ripon farm service <br /> Vickie, <br /> I 've got a work plan for some deep monitoring wells for Ripon Farm Service that I don't <br /> think went to your office. <br /> 938 Frontage Road, Ripon <br /> Would you mind taking a peek at their proposal and letting me know if there's something in <br /> there that should be altered? <br /> They're proposing two deep, conductor cased wells terminating at about 200 feet. <br /> Its attached. I'm also copying Harlin, as I left him a voice mail this morning also . . . <br /> Thanks, <br /> Amy Terrell <br /> Regional Water Board <br /> (916) 464-4680 <br /> 2 <br />