Laserfiche WebLink
named as pri <br />ary emergency coordinator and others shall be listed in the order in <br />which they wi <br />I assume responsibility as alternates. <br />(e) The plan shal <br />include a list of all emergency equipment at the facility (such as fire <br />extinguishing <br />systems, spill control equipment, communications and alarm systems <br />(internal andexternal), <br />and decontamination equipment), where this equipment is <br />required. This <br />list shall be kept up to date. In addition, the plan shall include the <br />location and e <br />physical description of each item on the list, and a brief outline of its <br />capabilities. <br />ssary in an emergency; <br />(f) The plan shall <br />nclude an evacuation plan for facility personnel where there is a <br />possibility tha <br />evacuation could be necessary. This plan shall describe signal(s) to <br />be used to be <br />in evacuation, evacuation routes, and alternate evacuation routes (in <br />cases where t <br />e primary routes could be blocked by releases of hazardous waste or <br />fires). <br />ber 16, 2013, inspection, the contingency plan was found to be <br />(g) The plan shall <br />include the current telephone number of the State Office of <br />Emergency S <br />rvices. <br />4 During the Oc <br />ober 16, 2013, inspection, the contingency plan was found to be <br />incomplete. <br />CCR 6625.54 C <br />ntingency plan not current. The contingency plan shall be <br />reviewed, anjim <br />ediately amended, if necessary, whenever: <br />(a) applicable reg <br />lations are revised; <br />(b) the plan fails i <br />an emergency; <br />(c) the facility cha <br />ges in its design, construction, operation, maintenance, or other <br />circumstances <br />in a way that materially increases the potential for fires, explosions, or <br />releases of ha <br />ardous waste or hazardous waste constituents, or changes the <br />response nec <br />ssary in an emergency; <br />(d) the list of emer <br />ency coordinators changes; or <br />(e) the list of emer <br />ency equipment changes. <br />4 During the Ja <br />uary 24, 2012, inspection, the emergency coordinator <br />information in th <br />contingency plan was not current. <br />4 During the Oc <br />ber 16, 2013, inspection, the contingency plan was found to be <br />incomplete. <br />CCR 66265.55 N emergency coordinator. At all times, there shall be at least one <br />employee either o the facility premises or on call (i.e., available to respond to an <br />emergency by rea hing the facility within a short period of time) with the responsibility for <br />coordinating all e ergency response measures. This emergency coordinator shall be <br />thoroughly familiar with all aspects of the facility's contingency plan, all operations and <br />activities at the fac lity, the location and characteristics of waste handled, the location of <br />all records within t e facility, and the facility layout. In addition, this person shall have the <br />authority to commi the resources needed to carry out the contingency plan. <br />4 During the Oct ber 16, 2013, inspection, the contingency plan did not identify <br />an emergency co rdinator. <br />CCR 66265.173(a) <br />when adding or re <br />shall always be clo: <br />remove waste. <br />4 During the Jam <br />blue plastic tub of <br />Failed to keep containers of hazardous waste closed except <br />noving hazardous waste. A container holding hazardous waste <br />ad during transfer and storage, except when it is necessary to add or <br />iary 24, 2012, inspection, a 5 -gallon bucket of waste liquid and a <br />used oil were found open and not in use. <br />