My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0016000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
646
>
2900 - Site Mitigation Program
>
SR0016000
>
SR0016000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2020 2:44:07 PM
Creation date
5/4/2020 2:29:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
RECORD_ID
SR0016000
PE
2910
STREET_NUMBER
646
Direction
S
STREET_NAME
CALIFORNIA
City
STOCKTON
Zip
95201
ENTERED_DATE
6/22/1998 12:00:00 AM
SITE_LOCATION
646 S CALIFORNIA
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
There is an existing water well approximately 12-inches in diameter on the property. The time of well <br /> construction predates Delta Pumps existence. Based on a recently recorded (03/30/98) downhole television <br /> video, the well is constructed of riveted steel casing from 0 feet to approximately 206 feet below ground <br /> surface (bgs). The well is open hole from approximately 206 feet bgs to the current bottom at approximately <br /> 218 feet bgs. The casing is apparently intact with no obvious breaks or offsets. Some scaling is apparent <br /> throughout the casing length. <br /> Use of the well prior to Delta Pumps existence is unknown. Delta Pumps installed an oil lubricated turbine <br /> pump in this well and used the water to fill pump test facilities and for truck cooling systems. The well water <br /> was so salty that the well was used for the pump testing facility only. Later (????), the oil lubricated turbine <br /> pump was removed and a one horsepower submersible pump was installed. <br /> Soil and Groundwater Testing and Results Summary <br /> Sampling and testing of soil and groundwater has been conducted by Delta Pumps. The following list <br /> summarizes these events: <br /> 1. Underground storage tank removal and associated soil sampling analyses (Results dated 01/12/89). <br /> San Joaquin County Health District inspected (we recall Dan Moe as the inspector) the tank removal <br /> and soil sampling efforts. No contaminated soil was noted during tank removal. The laboratory report <br /> for soil samples collected on January 3, 1989 from the tank excavation indicated total lead at 8 mg/kg <br /> and toluene at 23 µg/kg. No other BTEX or EDB detections were noted. <br /> 2. Soil samples collected under the east end of the main building (sampled 08/17/93). Samples were <br /> collected by GeoAnalytical Laboratories, Inc., as subcontracted by Thorpe Oil Company. Based on <br /> drawings and analytical reports, all samples were collected from approximately four (4) feet bgs <br /> beneath the building. The area was divided into four subareas. Soil in each subarea was sampled from <br /> three locations. The three individual soil samples from each subarea were composited so that each <br /> subarea had one composite soil sample. The composited soil samples were analyzed for 17 Metals and <br /> PC Oil & Grease, according to the laboratory invoice. <br /> 3. Existing well groundwater sample collected (sampled 09/29/93). The laboratory report for EPA <br /> Method 502.2 indicated 4.0µg/L chloroform and 5.3µg/L toluene present in the groundwater sample <br /> from the existing well. No other EPA Method 502.2 analytes were detected. <br /> 4. Existing well groundwater sample collected (sampled 03/24/94). Initial laboratory report dated <br /> 04/12/94 indicated non-detect for EPA Method 8020 (BTEX). Amended laboratory report dated <br /> 04/15/94 indicated 11µg/L benzene and non-detect for remaining EPA Method 8020 constituents. The <br /> reason for the amended laboratory report is unknown. The laboratory Report dated 04/12/94 indicated <br /> non-detect for TPH-Gas. <br /> 5. The well was aerated and groundwater sampled on 11/24/94. The laboratory report indicated non- <br /> detect for EPA Method 8020{BTEX). The purge water collected in a holding tank was also sampled <br /> on 11/24/94 and analyzed for EPA Method 8020(BTEX). The laboratory report indicated non-detect <br /> for the holding tank water. <br /> CAPROJECTS\Delta Pumps\splrslts.tlr Page 2 of 9 <br />