Laserfiche WebLink
4L 6 <br /> FLOW RATES AND ANALYTICAL RESULTS <br /> OF AIR SAMPLE ANALYSES <br /> Former ARCO Station No 6100 <br /> 25775 South Patterson Pass <br /> Tracy,California <br /> System Influent System <br /> Date Flowrate Influent Vacuum Sample ID Anal scs m nt3 <br /> acfm)t (scfm) Tem °I "WC GRO Benzene Toluene Ettly Ibell Zene X leues MIM, <br /> 03/01/06 26100 22227 16000 12240 6100 A INF 7,800 A 73 A 230 A 38 A 380 A <1 0 A <br /> 6100 A EFF <50 A <0 50 A <0 50 A <0 50 A <1 0 A <0 50 A <br /> WC-inches of water column <br /> Temp =Temperature in degree Fahrenheit QAIQC Review <br /> mg/m3=milligrams per cubic meter A-Data accepted without grialificaliou <br /> Flow rate(acrm)measured using standard calibrated devices is converted to standard flow rate(scfm)using the following formula J-Data accepted with ilunhfical lost <br /> femperature Corrected influent flow rate = Measured flow talc .((464 R+68deg F)!(deg F+460 R)) R-Data rcjc tcd <br /> Since flow rate is measured on the positive side of the liquid ring blower package vacuum correction is not applied <br /> [1)Reporting limits were raised due to high level of analyte present in the sample <br /> [21 The reported result exceeds nor mal dynamic range <br /> r Field data sheets record flow rate in feet per minute measured using an anemometer These readings were converted io flowrate(scfm units)in 4 inch diameter pipe <br /> Arco-6100 Quarterfy_O&M_500cfm Page 2 of 2JrR���cJ <br />