Laserfiche WebLink
2/10/2004 15 58 FAX 7145750026 SOLLECO INCORPORATED Z002 <br /> 500 TCAT (LR) THERMAL 1 CATALYTIC OXIDIZER <br /> TECHNICAL SPECIFICATIONS <br /> Oxidizer Specifications <br /> Chamber Length 10 feet <br /> Chamber Retention Time 1 second <br /> Stack Exit Velocity 10 feet/ second <br /> Throat Velocity 40 feet/second <br /> Stack Discharge Height 13 feet <br /> Skid Dimensions 7 feet wide / 12 feet long <br /> Trailer Dimensions 9 feet wide / 12 feet long <br /> Chamber Dimensions 40" round outside - 30" round inside <br /> Chamber Internal Lining Ceramic Fiber <br /> Chamber Mixing Throat Diameter 14" Round <br /> Burner Size 750,000 btu/hr (Maximum) <br /> Destruction Efficiency 98% + <br /> Maximum VOC Influent (Thermal) 12,000 ppmv (STEX - MTBE) <br /> Operating Temperature (Thermal) 1400°F to 16500 F <br /> Maximum VOC Influent (Catalytic) 3,500 ppmv (BTEX - MTBE) <br /> Operating Temperature (Catalytic) 600'F to 1200°F <br /> Normal VOC Effluent < 50 ppmv <br /> Blower Specifications_ <br /> Blower Type _ Travaini Liquid Ring TRO500S <br /> Volumetric Flow 540 CFM maximum <br /> Vacuum Level Up to 27" Mercury <br /> Motor Type 40 HP TEFC <br /> RPM 1750 <br /> Catalyst Specifications <br /> Catalyst Type Platinum Coated Metal Monolithic <br /> Catalyst Size 23" O D x 3 5" Height <br /> Catalyst Volume 85 ft3 <br /> Destruction Efficiency 98% + <br /> Maximum VOC Influent 3500 ppmv (BTEX/ MTBE) <br /> Normal VOC Effluent <50 ppmv <br /> Utility Specifications <br /> Supplemental Fuel Natural Gas or Propane <br /> Fuel Pressure 2 to 5 psi (Maximum) <br /> Fuel Volume 750 scfh (Maximum) <br /> Electrical Requirements 2081230 Volt— 3 Phase -$00 Amps <br />