Laserfiche WebLink
COMPUTATION SHEET <br /> PROJECT TITLE ARCO Facility No 6100 PROJECT NO U6100 <br /> DESCRIPTION Mass Emission rates SHEE- 1 OF 2 <br /> PREP BY Kiran Nagaraju DATE 1/6/2005 CHKD BY G Kowtha DATE <br /> CALCULATE <br /> Mass emission rates for the Solleco 500 cfm SVE system with <br /> thermal/catalytic oxidizer(Model 500 TCAT LR) <br /> ASSUMPTIONS <br /> 1 Local atmospheric pressure is equal to standard atmospheric pressure <br /> 2 Highest influent GRO concentration observed during the operation of King, Buck <br /> and Hasstech SVE systems=4 100 mg/3 or 1,004 5 ppmv <br /> 3 Molecular weight of GRO = 100 Ib-molellb <br /> 4 Molar volume of gas=379 5 ft3/Ib-mole <br /> 5 Control efficiency(manufacturer's literature) 98 percent <br /> 3 Temperature and pressure readings remain constant during the test <br /> 4 Effluent flow rate=Total influent flow rate+Combustion air flowrate+Natural gas consumption rate <br /> =500 ft3/min <br /> ABBREVIATIONS <br /> cfm Cubic feet per minute <br /> mg Milligram <br /> ppmv Parts per million by volume <br /> m3 Cubic meter <br /> lbs pounds <br /> TPHG Total petroleum hydrocarbons as gasoline <br /> ft/min Feet per minute <br /> ft3 Cubic feet <br /> Conc Concentration <br /> Y <br /> P\Hiles MarkeMR0061DO Emosson Cans <br />