My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0006719
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6230
>
2900 - Site Mitigation Program
>
PR0543479
>
ARCHIVED REPORTS_XR0006719
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2020 10:35:44 AM
Creation date
5/5/2020 9:46:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006719
RECORD_ID
PR0543479
PE
2960
FACILITY_ID
FA0024679
FACILITY_NAME
CANEPA'S CAR WASH
STREET_NUMBER
6230
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95204
APN
081360030
CURRENT_STATUS
01
SITE_LOCATION
6230 PACIFIC AVE
P_LOCATION
01
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site History <br /> Canepa's Car Wash(Pacific Avenue) <br /> Page 6 of 7 <br /> following development of the property that the MW-8 was located on Monitoring well MW-8 was <br /> destroyed by Condor on April 11, 2003 <br /> Condor conducted quarterly monitoring activities at the site on January 14 and 15, 2003 Laboratory <br /> analytical results of the groundwater samples indicated concentrations of petroleum hydrocarbon <br /> constituents consistent with historical data At the request of Mr Jeffrey Wong of the SJCEHD, <br /> groundwater monitoring for gasoline oxygenates/additives was reinitiated during the first quarter of 2003 <br /> 1,2-DCA and TBA were detected in groundwater samples collected from MW-3 and MW-11 at <br /> concentrations of 190 µg/1- and 15 gg/L, respectively The groundwater sample analytical results for <br /> MW-12D continued to indicate a trend of lower contaminant concentrations since the initial sampling <br /> event for this well conducted on October 25, 2001 The SVE system was temporarily removed from <br /> service for modifications on January 31, 2003 <br /> Condor conducted second quarter 2003 groundwater monitoring activities at the site on April 17 and 18, <br /> 2003 Laboratory analytical results of the groundwater samples indicated that concentrations of petroleum <br /> hydrocarbon constituents were generally consistent with historical data Groundwater elevation data <br /> indicated that the groundwater gradient was consistent with historical groundwater gradients The SVE <br /> system continued to be out of service for modifications, pending approval by the SJCEHD of the RAP <br /> submitted by Condor for the site <br /> Condor conducted annual groundwater monitoring activities during the third quarter 2003 at the site on <br /> July 25, August 1, and August 4, 2003 Laboratory analytical results of the groundwater samples <br /> indicated that concentrations of petroleum hydrocarbon constituents were generally consistent with <br /> historical data For the first time in the monitoring history of deep monitoring well MW-12D, none of the <br /> contaminants of concern were detected at or above the laboratory reported detection limits TBA and <br /> TAME were detected in the sample collected from MW-3 for the first time (I 10 and 13 4g/L, <br /> respectively) The concentration of MTBE detected in the groundwater sample collected from MW-3 is <br /> consistent with an increasing trend for that contaminant in that well Groundwater elevation data indicated <br /> that the groundwater gradient was consistent with historical groundwater gradients The SVE system <br /> continued to be out of service for modifications, pending approval by the SJCEHD of the RAP submitted <br /> by Condor for the site <br /> Condor conducted fourth quarter 2003 groundwater monitoring activities at the site on November 9, 2003 <br /> Four of the site monitoring wells historically used to estimate groundwater gradient/elevation were not <br /> utilized during the monitoring event Water level data from wells MW-2 and MW-11 were significantly <br /> different than water levels from nearby wells and were believed to be erroneous MW-5 and MW-10 had <br /> been paved over and were not relocated and restored until November 10 Laboratory analytical results of <br /> the groundwater samples indicated that concentrations of petroleum hydrocarbon constituents were <br /> generally consistent with historical data No constituents of concern were detected in the samples <br /> collected from monitoring well MW-9 and deep monitoring well MW-12D The concentration of MTBE <br /> detected in the sample collected from monitoring well MW-3 nearly doubled and was consistent with an <br /> increasing trend for that contaminant in that well The SVE system continues to ue out of service for <br /> modifications and to accommodate property development Condor was conducting remediation project <br /> planning/coordination/permitting and anticipated starting fieldwork in the spring of 2004 <br /> Condor conducted first quarter 2004 groundwater monitoring activities at the site on January 30, 2004 <br /> Monitoring wells MW-1, MW-2, MW-3, MW-4, MW-9, MW-11, and MW-12D and SVE well SV-4 <br /> were sampled and measured for water level during the event, consistent with the quarterly schedule <br /> . Groundwater elevation data and laboratory analytical results were generally consistent with historic <br /> groundwater monitoring data The concentrations of MTBE and other gasoline oxygenates in MW-3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.