R v M <br /> . December 15, 2004 Lab ID STK438223 <br /> Micheline Doyle Kipf Customer 3-14626 <br /> Quality Control - Organic <br /> =Constituent Method Date/ID Type Units Conc QC Data DQO Note <br /> Toluene 5030B 11/30/2004 A233 MS ug/L 5000 857% 73-128 <br /> (SP 412128 02) MSD ug/L 5000 964% 73-128 <br /> MSRPD ug/L 11 8% X23 6 <br /> 8260B 11/30/2004 A 00-CCV ug/L 5000 964% 80-120 <br /> Toluene-d8-Surrogate 50308 11/30/2004 A233 Blank ug/L 2500 916% 84-112 <br /> LCS ug/L 2500 920% 84-112 <br /> MS ug/L 25 00 95 1% 84-112 <br /> (SP 412128-02) MSD ug/L 25 00 906% 84-112 <br /> 8260B 11/30/2004 A 01-CCV ug/L 25 00 102% 70-130 <br /> Xylenes in p 50308 11/30/2004 A233 Blank ug/L ND C I <br /> 8260B 11/30/2004 A 00-CCV ug/L 1000 109% 70 130 <br /> Explanations <br /> 210 The method blank was positive However, samples reported were either ten times greater than the blank <br /> concentration or non detect and accepted <br /> 305 LCS not within Acceptance Range (AR) Data could not be confirmed by reanalysis Results were <br /> reported with client approval <br /> 310 LCS above Acceptance Range (AR) Samples which were non detect for this analyte were accepted <br /> 320 LCS not within Acceptance Range (AR) Data was accepted based on the BS/BSD recovery <br /> 355 CCV not within Acceptance Range (AR) Results were reported with client approval <br /> 360 CCV above Acceptance Range (AR) Samples which were non detect for this analyte were accepted <br /> 410 Relative Percent Difference (RPD) not within Maximum Allowable Value (MAV) Data was accepted <br /> based on the LCS or CCV recovery <br /> 435 Sample matrix may be affecting this analyte Data was accepted based on the LCS or CCV recovery <br /> Definitions <br /> Blank Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples <br /> LCS Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte <br /> recovery <br /> PDS Post Digestion Spike (TCP/GPAA) <br /> MS/MSD Matrix Spikes - A random sample is spiked with a known amount of analyte The recoveries are an indication of <br /> how that sample matrix affects analyte recovery <br /> BS/BSD Blank Spikes - A blank is spiked with a known amount of analyte It is prepared to verify that the preparation <br /> process is not affecting analyte recovery <br /> Dup Duplicate Sample - A random sample with each batch is prepared and analyzed in duplicate The relative percent <br /> difference is an indication of precision for the preparation and analysis <br /> CCB Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria <br /> CCV Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria <br /> ND Non-detect - Result was below the DQO listed for the analyte <br /> DQO Data Quality Objective - This is the criteria against which the quality control data is compared <br /> STK438223 Quality Control Page 13 <br />