Laserfiche WebLink
' QUARTERLY MONITORING REPORT JULY 1997 <br /> CANEPA S CAR WASH <br /> 6230 Pacific Avenue Stockton CA <br /> August 14 1997 <br /> 3 0 QUARTERLY GROUNDWATER MONITORING- JULY, 1997 <br /> The work conducted during the quarterly groundwater monitoring was outlined by Condor in <br /> Proposal foi Site Evaluation and Groundwater Monitoring (April 8, 1996) The scope-of-work <br /> presented in the proposal was approved by Mr Ronald Rowe of the PHS/EHD <br />' On July 17 and 18, 1997, Condor personnel made field observations and collected groundwater <br /> samples from the eight monitor wells at the site (see Figure 2, Appendix A for well locations) In <br /> addition, at the request of Mr Rowe, a groundwater sample was also collected from soil vapor <br /> extraction well SV-3 The order of sampling was MW-5, MW-4, MW-8, MW-6, MW-7, MW-3, MW- <br /> 2, SV-3, and MW-1 All held equipment was decontaminated in the field with a solution of <br /> laboratory-grade, non-phosphate detergent and hydrocarbon-free water and rinsed with hydrocarbon- <br /> free water prior to use in each well All field instruments were calibrated to the manufacturer's <br /> recommended standards The water level in each well was measured to the nearest 0 01 foot with a <br /> standard battery-operated, flat-tape, water-level meter A new, disposable, polyethylene bailer was <br /> lowered into each well to collect a field-inspection sample The bailer sample was inspected for <br /> floating product, sheen, discoloration and/or odor Floating product was not observed in any of the <br /> monitor wells during the groundwater sampling However, water levels in the wells were above the <br /> top of the well screens in the wells A slight petroleum odor was detected in MW-I and MW-2 and a <br /> strong petroleum odor was detected in SV-3 <br /> Each well was purged with a dedicated bailer until at least three well-casing volumes of water <br /> were removed and until the pH, specific conductance, and temperature of the water had stabilized <br /> Groundwater Monitoring Field Forms are included in Appendix B Prior to sampling, the water was <br /> allowed to recover to at least 80% of the pre-purge water level The purge water was discharged to <br /> 55-gallon drums and left on site to await disposal For each well <br /> • A groundwater sample was collected with a disposable, one-time-use, polyethylene <br /> bailer The sample was transferred to two (2) 40-ml glass VOA vials fitted with <br /> Teflon-lined caps Each vial was inverted and tapped to assure that no air bubbles <br /> were present <br /> • Each vial was labeled and placed in a cooler chilled with ice and delivered under <br /> chain-of-custody procedures to GeoAnaIytical Laboratories, Inc , in Modesto, <br /> California, within 24 hours of sample collection The results of laboratory analyses <br /> are discussed in Section 4 2 <br />• 4 0 INVESTIGATION RESULTS <br /> l4 1 Laboratory Analyses <br /> The groundwater samples were analyzed for total petroleum hydrocarbons, quantified as <br /> gasoline (TPH-G) by Method 5030/LUFT and for benzene, toluene, ethyl benzene, and xylene (BTEX) <br /> and methyl tertiary butyl ether (MTBE) by EPA Method 602 MTBE was detected by EPA Method <br /> 602 and confirmed by EPA Method 8260 in some of the groundwater samples collected during the <br /> Page -2- N&I *_ <br /> It{ CONDOR <br />