Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.orq/ehd <br /> Underground Storage Tank Program Inspection Report IAMIIIL <br /> Facility Name: Facility Address: Date: <br /> Yosemite Avenue Arco AmPm 1711 E Yosemite Ave, Manteca June 15, 2015 <br /> UST System Observations <br /> 319 HSC 25291(e) water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) ■V D R ❑COS <br /> 320 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion D V D R D COS <br /> 25290.1(c3) <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump ❑V D R D COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed D V D R D COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi D V ❑R ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty D V D R D COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons D V ❑R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present,was overridden,or failed to meet overfill requirements D V D R o COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status D V ❑R D COS <br /> 328 CCR 2717.1(g) Tampered with red tag o V ❑R D COS <br /> 329 CCR 2717.1(f) Deposited petroleum into a red tagged UST D V ❑R o COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms o V D R D COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored D V ❑R D COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements o V D R D COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements D V D R D COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve D V D R D COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V D R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R D COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed (pre-January 1984) D V o R D COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation D V D R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation D V D R D COS <br /> 2060 See below Unlisted Design/Construction violation ❑V c R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> Received by Inspector: Phone: Date: <br /> (initial): V` ELENA MANZO, REHS (209) 953-7699 06/15/2015 <br /> yy\a_l 1 Page 3 of 5 <br />