My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 1:54:57 PM
Creation date
5/5/2020 4:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
459
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVEE) <br /> SWRCB,January 2002 '1Page,of_ <br /> S. FILL RISER CONTAINMENT SUMP TESTING 1OA' <br /> Facility is Not TTuipped With Fill Riser Containment Sumps <br /> Fill Riser Containment Sumps are Present,but were Not Tested C"' IR N <br /> Test Method Developed By: 0 Sump Manufacturer _!Industry Standard U Prof H <br /> U Other(Spec) <br /> Test Method Used: D Pressure U Vacuum U Hydrostatic <br /> G Other(Spec) <br /> Test Equipment Used: Equipment Resolution: <br /> Fill Sump# Fill Sump# Fill Sump# Fill Sump# <br /> Sum Diameter: <br /> Sump D th: <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: _ <br /> Condition of sump prior to <br /> testing: <br /> Portion of Sump Tested <br /> Surnp Material: <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(RO: <br /> Test End Time: ---- <br /> Final Reading(RF): _ <br /> Test Duration: <br /> Change in Reading(RF-111): <br /> Pass/Fail Threshold or Criteria: _ <br /> Test Result: L Pass 0 FailPass 7 Fail Pass C Fail ❑.Paas ( Fail <br /> Is there a sensor in the sump? 1:. Yes C No ❑Yes U No U Yes U No ❑Yes U No <br /> Does the sensor alarm when U Yes U No ❑NA <br /> either product or water is U Yes U No U NA U Yes :a No U NA 1'.1 Yes F;No U NA <br /> detected? <br /> Was sensor removed for testing? U Yes U No U NA U Yes U No U NA U Yes U No U NA C:Yes C.No U NA <br /> Was sensor properly replaced and I::: Yes U No I::1 NA <br /> verified functional after testing? ❑Yes U No DNA 171 Yes i No U NA U Yes 1'..jNo O NA <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br />