My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 1:54:57 PM
Creation date
5/5/2020 4:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
459
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN .JOAQUIN Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Yosemite Avenue Arco AmPm 1 1711 E Yosemite Ave, Manteca June 05,2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the October 2017 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include: Q1 PLLD gross line fail on 10/15/2017.Also the designated operator did not print out the <br /> prove alarms nor did he print out the Electronic line leak detector(Q1)alarms in the last 12 month reports. In their <br /> monitoring plan this facility list audible and visual alarms as overfill preventions. During the monthly inspection,the <br /> designated operator shall review the alarm history for the previous month, check that each alarm was documented <br /> and responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br /> alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br /> including all of the required information on the reports. <br /> This is a repeat violation, Class ll. <br /> 211 CCR 2715(0(2) Designated operator employee training not performed or log not kept. <br /> The designated operator employee training for Maria Pedroza last trained on 10/6/2016, Bhadar Singh and Gurman <br /> Singh were last trained 5/8/2017 and therefore not current. The designated operator shall train facility employees <br /> for which he or she is responsible in the proper operation and maintenance of the UST system once every 12 <br /> months. The training shall include,but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site,and submit a copy of <br /> the training records to the EHD. <br /> This is a repeat violation, Class II. <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> Fuel filters were observed outside of all under dispenser containments at the facility.The underground storage tank <br /> system shall be operated to prevent unauthorized releases. Immediately contact a properly licensed,trained, and <br /> certified contractor to replace or upgrade the component under permit and inspection with the EHD <br /> This is a Class II violation. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the 91 product and 87-2 product fill sump. If water could enter into the secondary <br /> containment by precipitation or infiltration, it must be removed and disposed of properly. The service technician <br /> removed all of liquid from the fill sumps. Ensure that all sumps and annular spaces are maintained free of liquid. <br /> This was corrected on site. <br /> This is a repeat violation, Class Il. <br /> Overall Inspection Comments: <br /> FA0003612 PR0231455 SCO01 06/05/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.