My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 1:54:57 PM
Creation date
5/5/2020 4:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
459
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Yosemite Avenue Arco AmPm 1 1711 E Yosemite Ave, Manteca June 05,2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> The facility did not provide or document all alarms. The missing alarms include a Q1 87 leak detector that had a <br /> gross line fail alarm that occurred on 9/19/2016. These records shall be maintained on site for at least three years. <br /> Monitoring records include: (1)date and time of all monitoring or sampling; (2)monitoring equipment calibration and <br /> maintenance records; (3)results of any visual observations; (4)results of sample analysis performed a lab or in the <br /> field; (5)logs of all readings of gauges or other monitoring equipment,ground water elevations, or other test results; <br /> (6)results of inventory readings and reconciliations. Immediately locate and maintain all missing maintenance and <br /> monitoring records for the last three years on site and submit copies along with documentation of the alarm follow <br /> up to the EHD. <br /> This is a minor violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator(DO)failed to document all the alarms from the attached alarm history on the designated <br /> operator monthly inspection reports and failed to check that they were responded to appropriately. <br /> On 10/6/2016,the DO failed to document a 87 regular PLLD gross line fail alarm on 9/19/2016. <br /> On the 3/6/2017 DO report, the DO failed to document a sensor out and a fuel alarm on 2/9/2017 and 2/11/2017 <br /> (respectively). <br /> On the 7/26/2016, 9/8/2016, 10/6/2016, 11/3/2016, 12/19/2016, 1/10/2017, 2/1/2017, 3/6/2017,4/5/2017 and <br /> 5/8/2017 DO inspection reports,the DO forgot to print out the T1,T2, and T3 tank alarms. <br /> On the 9/8/2016, 10/6/2016, 11/3/2016, 12/19/2016, 1/10/2017, 2/1/2017, 3/6/2017,4/5/2017 and 5/8/2017 DO <br /> inspection reports,the DO forgot to print out the Q1 87 PLLD alarm. <br /> During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> 306 CCR 2630(d)Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 87 grade slave and master 323 sensors located in the submersible turbine pump sumps had fallen diagonally <br /> and were not located to detect a leak at the earliest possible opportunity. Monitoring equipment shall be maintained <br /> to be able to detect a leak at the earliest possible opportunity. The sensor was relocated to the lowest point of the <br /> sump by the service technician. Ensure that all monitoring equipment is maintained to detect a leak at the earliest <br /> opportunity. <br /> This was corrected on site. <br /> This is a repeat violation, Class Il. <br /> FA0003612 PR0231455 SCO01 66/05/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.