on <br /> � CV <br /> N � <br /> GENERAL PLUMBING NOTES STANDARD ABBREVIATIONS PLUMBING LEGEND r 1 <br /> WATER AND WASTE SERVICE CALCULATIONS WATER PIPE SIZING CHART A. INSTALL ALL PLUMBING SYSTEMS IN ACCORDANCE WITH THE ADOPTED VERSION OF THE ENERGY EFFICIENCY STANDARDS, CALIFORNIA (E) EXISTING • U <br /> JOB NAME. FAIRFIELD LODI BATE. 10124J18 <br /> BUILDING CODE,CALIFORNIA MECHANICAL CODE,AND CALIFORNIA PLUMBING CODE AND ALL OTHER LOCAL CODES AND ADOPTED AFF ABOVE FINISHED FLOOR BALL VALVE - DOMESTIC COLD WATER (DCW) , w <br /> - ORDINANCES. <br /> PIPE SIZES CALCULATED BASED ON CALIFORNIA PLUMBING CODE Al ANALOG INPUT <br /> WASTE COLD WATER HOT WATER TOTAL B. CLOSELY COORDINATE ALL PLUMBING WITH ELECTRICAL,ARCHITECTURAL,AND STRUCTURAL.COORDINATE FIRE LINE STUB BUTTERFLY VALVE - - DOMESTIC HOT WATER (DHW) <br /> FIXTURE TYPE OCCUPANCY NO. WATER REQUIREMENTS IN FIRE RISER ROOM WITH GENERAL CONTRACTOR/FIRE PROTECTION CONTRACTOR. PIPING IS APPROXIMATE AND ALT ALTERNATE IE <br /> SIZE: TYPE L COPPER CW MAX FLOW CW FIXTURE UNIT VALUES HW MAX FLOW HWFU r 1 <br /> O N FU TOTAL FU TOTAL FU TOTAL FU DIAGRAMMATIC AND ISNOT TO BE SCALED. PROVIDE ALTERNATE ROUTING,OFFSETS,AND TRANSITIONS AS REQUIRED FOR AO ANALOG OUTPUT GATE VALVE - - - - DOMESTIC HOT WATER RECIRC. (DHWR) `J <br /> BATHTUBISHOER PRIVATE 73 2 d6 3 219 3 279 292 COORDINATION OF ALL WORK WITHOUT ADDITIONAL COST TO THE OWNER. CAP. CAPACITY <br /> M - NOMINAL INTERNAL HOT GLOBE VALVE UDCW UNSOFTENED DOMESTIC COLD WATER (UDC <br /> GPM FPS FLUSH TANK FLUSH VALVE GPM FPS C. FIELD VERIFY ALL PLUMBING PRIOR TO COMMENCING NEW WORK. DO NOT FABRICATE OR INSTALL ANY PLUMBING BEFORE VERIFYING CTG CLEANOUT TO GRADE ( ) <br /> DISHWASHER,DOMESTIC PRIVATE 1 2 2 0 0 1.5 1.5 1.5 DIAMETER DIAMETER WATER DIMENSIONS AND ROUTING WITH BUILDING CONDITIONS AND ALL OTHER TRADES. <br /> CV CONSTANT VOLUME � MOTORIZED VALVE OPERATOR (TEMP)°F DOMESTIC HOT WATER (SPECIFIED TEMP.) <br /> DRINKING FOUNTAIN PUBLIC 2 0.5 1 0.3 1 0 0 1 1/2" 0.545 3.0 4.1 3 0 3.0 4.1 3 D. INSTALL ALL EQUIPMENT AND DEVICES PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE ONE YEAR PARTS AND LABOR WARRANTY CWFU COLD WATER FIXTURE UNITS RED INC ARCHITECTS <br /> ON INSTALLATION. DFU DRAINAGE FIXTURE UNITS v ° DOMESTIC HOT WATER RECIRC. 121sT STREET,MODESTO,CA 95354 <br /> HOSE BIBB(FIRST) PUBLIC 6 0 0 2.3 15 0 0 15 314" 0.785 4.6 3.0 4 0 4.6 3.0 4 E. CONTRACTOR IS RESPONSIBLE FOR ALL APPLICABLE PERMITS AND FEES. CHECK VALVE(SWING OR LIFT AS REQ'D) -DHWR(TEMP) F- (DHWR-SPECIFIED TEMP.) 209.522.8900 <br /> LAVATORY PRIVATE 73 1 73 0.73 54.75 0.75 54,75 73 DI DIGITAL INPUT <br /> 1" 1.025 9.2 3.6 12 fl 9 2 3 6 12 F. CAULK AND SEAL ALL PENETRATIONS THROUGH CEILINGS,WALLS,AND FLOORS. PROVIDE ESCUTCHEON COVERS OR SHEET METAL DIA OR DIAMETER 4 SOLENOID VALVE - - - - - - - SANITARY VENT (VT) <br /> LAVATORY PUBLIC 6 1 6 0.73 4.5 13.75 4.5 6 FLANGES ON ALL VISIBLE PENETRATIONS. <br /> } KITCHEN SINK,DOMESTIC PRIVATE 6 2 12 1.125 6.75 1.125 6.75 9 1-114" 7.265 16.0 4.1 21 fl 16.0 4.1 21 G. PROVIDE SEISMIC RESTRAINTS FOR PLUMBING EQUIPMENT AND PIPING TO COMPLY WITH SEISMIC DESIGN CRITERIA LISTED IN THE 0 DIGITAL OUTPUT 4 AUTOMATIC CONTROL VALVE(2-WAY) SANITARY SEWER ABOVE GRADE (SS) SEAL: <br /> STRUCTURAL GENERAL NOTES. IF NOT AVAILABLE PROVIDE RESTRAINTS IN ACCORDANCE WITH ASCE/SEI 7-10 AND CALIFORNIA BUILDING <br /> SERVICE SINK PRIVATE 1 3 3 1.125 1.125 1.125 1.125 1.5 1-112" 1.505 25.3 4.6 42 8 25.3 4.6 42 CODE WITH SEISMIC DESIGN CATEGORY D,SITE CLASS D, RISK CATEGORY II, SHORT PERIOD DESIGN SPECTRAL RESPONSE DSN DOWNSPOUT NOZZLE AUTOMATIC CONTROL VALVE(3-WAY) - - SANITARY SEWER BELOW GRADE (SS) <br /> URINAL,1.0 GPF PUBLIC 1 2 2 4 4 1 0 0 4 ACCELERATION COEFFICIENT SDS=0.606, ONE SECOND PERIOD DESIGN SPECTRAL RESPONSE ACCELERATION COEFFICIENT SD1=0.362, DW DISHWASHER <br /> 2" 1.985 52.3 5.4 135 52 48.2 5.0 119 AND IMPORTANCE FACTOR 1.0. PIPING SUPPORTED WITHIN 12"OF STRUCTURE DOES NOT REQUIRE SEISMIC BRACING. EFF EFFICIENCY PRESSURE REDUCING VALVE HEAT TRACING Q�oF s ON <br /> N.ST qe <br /> WATER CLOSET, GRAVITY TANK PUBLIC 73 4 292 2.5 182.5 0 0 182.5 2-112" 2.465 92,4 6.2 337 205 74.4 5.0 245 H. IF DISCREPANCIES EXIST BETWEEN BUILDING CODES, DRAWINGS, NOTES,AND SPECIFICATIONS,THE MOST STRINGENT REQUIREMENT ELEV ELEVATION e`` GN �7G F'G <br /> ,��, <br /> WATER CLOSET, FLUSH VALVE PUBLIC 6 4 24 5 30 0 0 30 WILL BE REQUIRED UNLESS CLARIFIED BY PROJECT ENGINEER IN AN OFFICIAL ADDENDUM OR SUPPLEMENTAL INSTRUCTION. EWT ENTERING WATER TEMPERATURE P&T RELIEF VALVE CHS CHILLED WATER SUPPLY �' m <br /> 3" 2.945 147.6 7.0 622 536 106.2 5.0 411 I. ALL DETAILS INCLUDED IN DESIGN DRAWINGS MUST BE APPLIED TO ALL RELEVANT INSTALLATIONS REFERRED TO IN THE DETAIL. EACH FA FREE AREA " " <br /> FLOOR DRAIN,2" PRIVATE 4 2 8 0 0 0 0 0 M37119 <br /> DETAIL WILL NOT BE SPECIFICALLY REFERENCED ON THE DRAWINGS. � PET COCK OR GAUGE COCK CHR CHILLED WATER RETURN EXP.9-30-2021 <br /> FOT4" 3.905 261.3 7.0 1426 1428 188.8 5.0 847 FCO FLOOR CLEANOUT <br /> FLOOR DRAIN, 2" PUBLIC 3 2 6 0 0 0 0 0 DOMESTIC WATER <br /> FD FLOOR DRAIN � <br /> n CALIBRATED BALANCING VALVE CD CONDENSATE DRAIN s � P �P <br /> EXTRACTOR PRIVATE 2 8 16 8 16 8 16 21.333333 5" 4.875 407.2 7.0 2737 2740 290.9 5.0 1668 A. PROVIDE AND INSTALL WATER METER PER LOCAL JURISDICTION REQUIREMENTS. COORDINATE LOCATION WITH CIVIL. INSTALL WATER T FCHAN\O <br /> METER READING DEVICE PER LOCAL JURISDICTION REQUIREMENTS. FPM FEET PER MINUTE qTF OF C,A_\F <br /> m FS FLOOR SINK Q WATER HAMMER ARRESTOR CWS CONDENSOR WATER SUPPLY <br /> D 6" 5.845 585.4 7.0 4357 4357 418.2 5.0 2843 B. PROVIDE AND INSTALL UL LISTED DOUBLE CHECK BACKFLOW PREVENTER OR REDUCED PRESSURE BACKFLOW PREVENTER PER LOCAL <br /> o FT FEET 04/12/2019 <br /> 0 TOTAL FU 600.0 534.6 3133.6 636.8 � JURISDICTION ON DOMESTIC WATER SERVICE.WHERE WATER MAIN PRESSURE EXCEEDS 80 PSI PROVIDE AND INSTALL ASSE 103 AIR VENT(AUTOMATIC) <br /> 8 7.725 1022.6 7.0 8300 8300 73n 5.0 5650 FW FRESH WATER CWR CONDENSOR WATER RETURN <br /> EQUIVALENT COLD WATER FLOW RATE (GPM): 164 APPROVED PRESSURE REDUCING VALVE AND STRAINER. <br /> C. ALL DOMESTIC WATER PIPING ROUTED BELOW SLAB TO HAVE MINIMAL TO NO JOINTS OR FITTINGS BELOW SLAB. GA GAUGE STRAINER FS FIRE SPRINKLER SERVICE <br /> ADDITIONAL DEMAND LOAD{GPM) a D. PROVIDE WATER HAMMER ARRESTOR IN EACH BRANCH LINE SERVING FIXTURES AND EQUIPMENT WITH AUTOMATIC VALVE OPERATORS. GAL GALLON CONSULTANT: <br /> PRESSURE AVAILABLE AT MAIN MPSI): 45 SIZE AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. GD GARAGE DRAIN VENTURI FLOW METER HWS HEATING WATER SUPPLY <br /> PRESSURE BOOSTER PUMP 59 E. INSULATE ALL DOMESTIC HOT WATER PIPING AND RECIRCULATION PIPING AND DOMESTIC COLD WATER PIPING PER INSULATION TABLE. GPM GALLONS PER MINUTE <br /> PROVIDE ALUMINUM JACKET ON ALL INSULATION LOCATED OUTDOORS. HP HORSEPOWER T TEMPERATURE&PRESSURE TEST PLUG HWR HEATING WATER RETURN <br /> MINIMUM REQUIRED FIXTURE PRESSURE (PSI): 25 F. ROUTE WATER PIPING IN HEATED AREAS ONLY. DO NOT ROUTE PIPING IN NON-INSULATED ATTIC,CEILING AND WALL SPACES. HR HOUR F <br /> ELEVATION RISE(FT): 413 <br /> G. DISINFECT DOMESTIC WATER PIPING. HT HEIGHT FLOW SWITCH LP <br /> T <br /> METER LOSS (PSI): 3 H. PRESSURE TEST ALL DOMESTIC WATER PIPING PER PLUMBING CODE REQUIREMENTS. HWFU HOT WATER FIXTURE UNITS TEMPERATURE SENSOR NG NATURAL GAS <br /> BACKFLOW PREVENTER LOSS{PSI}; ID I. ALL INSTALLATIONS OF PEX PIPE INSTALLED SHALL BE FLUSHED TWICE OVER A PERIOD OF AT LEAST ON WEEK.THE PIPE SYSTEM SHALL IAQ INDOOR AIR QUALITY 17, <br /> BE FIRST FLUSHED FOR AT LEAST 10 MIN.AND THEN FILLED AND ALLOWED TO STAND FOR NO LESS THAN 1 WEEK,AFTER WHICH ALL THE IN. INCH PRESSURE GAUGE W/GAUGE COCK OD OVERFLOW DRAIN <br /> ADDITIONAL LOSSES{PSI): (WATER SOFTNER: 15 PSI, MIXING VALVE: 5 PSI, CIVIL TO BUILDING: 1 30 BRANCHES OF THE PIPE SYSTEM SHALL BE FLUSHED LONG ENOUGH TO FULLY EMPTY THE CONTAINED VOLUME.AT THE TIME OF FILL, $ ENGINEERING SYSTEM SOLUTIONS <br /> li INWC INCHES OF WATER COLUMN + STRUCTURAL•MEP•BUILDING COMMISSIONING <br /> EQUIVALENT PIPE LENGTH FROM METER T4 MOST REMOTE FIXTURE(FT): 323 EACH FIXTURE SHALL HAVE A REMOVABLE TAG APPLIED STATING:"THIS NEW PLUMBING SYSTEM WAS FIRST FILLED AND FLUSHED ON THERMOMETER RD ROOF DRAIN OR EXTERIOR DRAIN <br /> NAME .THE STATE OF CALIFORNIA REQUIRES THAT THE SYSTEM BE FLUSHED AFTER STANDING AT LEAST INWG INCHES OF WATER GAUGE BUILDING RELATIONSHIPSXPECTION <br /> (DATE)BY ( ) EXCEEDING EXPECTATIONS <br /> FRICTION LOSS PRESSURE AVAILABLE (PSI): 9.64 ONE WEEK AFTER THE FILL DATE SPECIFIED ABOVE. IF THIS SYSTEM IS USED EARLIER THAN ONE WEEK AFTER THE FILL DATE,THE WATER LBS POUNDS (Y��1 PUMP RL REFRIGERANT LIQUID www.es2eng.com <br /> MAXIMUM ALLOWABLE FRICTION LOSS (PSI1100 FT): 2.911 MUST BE ALLOWED TO RUN FOR AT LEAST TWO MINUTES PRIOR TO USE FOR HUMAN CONSUMPTION.THIS TAG MAY NOT BE REMOVED LWT LEAVING WATER TEMPERATURE 4943 NORTH 29TH EAST,STE A <br /> PRIOR TO THE COMPLETION OF THE REQUIRED SECOND FLUSHING, EXCEPT BY THE BUILDING OWNER OR OCCUPANT."CONTRACTOR TO MAX MAXIMUM IDAHO FALLS,IDAHO 83401 <br /> WATER FLOW VELOCITY(FPS): 4.38 PROVIDE WRITTEN CERTIFICATION THAT THEY WILL COMPLY WITH THE FLUSHING PROCEDURES SET FORTH IN THIS CPC SECTION 604.1.2. ELBOW DOWN RS REFRIGERANT SUCTION PHONE:I208I 552-9874 <br /> CALCULATED FRICTION HEAR LOSS (PSI1100 FT): 0.91 <br /> ANY CONTRACTOR OR SUBCONTRACTOR FOUND TO HAVE FAILED TO COMPLY WITH THE PEX FLUSHING REQUIREMENTS SHALL BE MBH THOUSAND BRITISH THERMAL UNITS/HOUR <br /> MECH MECHANICAL ELBOW UP S STEAM JOB NUMBER: 17.1019 <br /> SUBJECT TO THE PENALTIES IN HEALTH AND SAFETY CODE, DIVISION 13, PART 1.5,CHAPTER 6(SECTION 17995 ET SEQ.). REFER TO CPC <br /> MINIMUM REQUIRED-WATER'PIPE 51LE(INCHES}: 4 604.1.2 FOR ADDITIONAL INFORMATION. MIN MINIMUM t"'°`°T'°„""°'"^""°Tat"tIR°°°`�t°'11111 RM"'T"RTY °�lwIRF-� <br /> °5,7"FRO atR��.� a R=OHR 6NERNGSYSTEMSOL s <br /> MINIMUM REQUIRED-WASTE-PIPE SIZE (INCHES): 6 J. INSTALL HYDRONIC TRAP PRIMERS ON ALL FLOOR DRAINS AND FLOOR SINKS UNLESS NOTED OTHERWISE. INSTALL TRAP PRIMERS NC NOISE CRITERIA TEE DOWN SD STORM DRAIN <br /> (CALCULATIONS PER THE CALIFORNIA PLUMBING CODE-APPENDIX A) COMPLYING WITH ALL MANUFACTURER REQUIREMENTS. PROVIDE ACCESS PANEL FOR ALL TRAP PRIMERS AND COORDINATE LOCATIONS NIC NOT IN CONTRACT D+ HOSE BIB OR SILLCOCK ** PIPING BELOW GRADE(-SYS.ABR.) <br /> WITH GENERAL CONTRACTOR/ARCHITECT. ALL TRAP PRIMERS TO BE INSTALLED ON BRANCH PIPING SERVING REGULARLY USED FIXTURE NO. NUMBER <br /> TO ENSURE CORRECT OPERATION. NOM NOMINAL ] PIPE CAP POINT OF REMOVAL FROM EXISTING <br /> K. PROVIDE AND INSTALL BACKFLOW DEVICES PER LOCAL JURISDICTION REQUIRMENTS ON ALL CLOTHESWASHER&ICE MAKERS DCW AND NTS NOT TO SCALE <br /> DHW SUPPLY LINES. <br /> EQUIPMENT AND FIXTURES OD OVERFLOW DRAIN REDUCER VALVE POINT OF CONNECTION TO EXISTING <br /> OSA OUTSIDE AIR • <br /> A. COORDINATE ALL ELECTRICAL AND CONTROL REQUIREMENTS WITH ELECTRICIAN. PD PRESSURE DROP UNION P## KEYED NOTE <br /> B. PROVIDE SUBMITTALS ON ITEMS LISTED IN SCHEDULES TO ENGINEER FOR REVIEW PRIOR TO ORDER, PURCHASE,OR INSTALLATION. ALL PRV PRESSURE REDUCING VALVE <br /> Fcw wfield <br /> REQUIRED SUBMITTALS TO BE SUBMITTED IN A SINGLE TABBED BINDER. PROVIDE ALL HVAC AND PLUMBING CONSTRUCTION COSTS FOR YARD HYDRANT/ROOF HYDRANT INN & SUITES <br /> ENGINEER DATA BASE AS PART OF SUBMITTALS. PSI POUNDS PER SQUARE INCH sEc# <br /> NOTES: C. ALL MANUFACTURER SUBSTITUTIONS MUST BE SUBMITTED THROUGH ARCHITECT AND APPROVED THROUGH AN ADDENDUM. PRIOR PSIG POUNDS PER SQUARE INCH GAUGE O FLOOR DRAIN SHEET# SECTION CUT LINE <br /> A. GAS COMPANY TO PROVIDE 2700 MBH AT 2 PSI APPROVALS MUST BE SUBMITTED 10 DAYS PRIOR TO BID DATE. RD ROOF DRAIN BY MARRIOTT <br /> DOWNSTREAM OF METER TO SERVE BUILDING. D. PROVIDE OPERATIONS AND MAINTENANCE MANUAL INCLUDING ALL PLUMBING EQUIPMENT. RPBP REDUCED PRESSURE BACKFLOW PREVENTER FLOOR SINK <br /> B. GAS PIPING SIZED PER LONGEST LENGTH METHOD PER E. PROVIDE TRAPPED CONDENSATE DRAINS PIPED FULL SIZE TO FLOOR DRAIN FOR ALL AIR CONDITIONING EQUIPMENT AND HIGH SL SEA LEVEL 4 <br /> TABLES 1216.2(1)AND 1216.2(4)OF THE CPC. EFFICIENCY FURNACES AND BOILERS. SP STATIC PRESSURE - �- - CLEANOUT TO GRADE(COTG) P5.1 DETAIL TAG <br /> C. MAXIMUM EQUIVALENT LENGTH FROM METER TO THE MOST F. REFER TO ARCHITECTURAL FLOOR PLANS FOR EXACT FIXTURE LOCATIONS AND MOUNTING HEIGHTS. SQ FT SQUARE FEET FLOOR CLEANOUT(FCO) <br /> REMOTE OUTLET OF 400'. G. PROVIDE BALANCE VALVES TO ALLOW COMPLETE BALANCE OF PLUMBING SYSTEMS AND ISOLATION VALVES FOR MAINTENANCE ON EACH SR STORY RISER <br /> D. 11 IN.W.C. PIPING SIZED DOWNSTREAM OF THE EACH PIECE OF EQUIPMENT. - <br /> SS SERVICE SINK OR STAINLESS STEEL C-11 WALL CLEANOUT(WCO) <br /> REGULATOR AT THE MAXIMUM EQUIVALENT LENGTHS H. PROVIDE ISOLATION VALVES FOR ALL BRANCH LINES SERVING THREE OR MORE FIXTURES. PROVIDE BALANCING VALVES FOR EACH TSP TOTAL STATIC PRESSURE <br /> SHOWN NEAR EACH REGULATOR. DOMESTIC HOT WATER RETURN PIPING OF TWO BRANCHES OR MORE. VAV VARIABLE AIR VOLUME EXPANSION JOINT NOT ALL <br /> E. ALL GAS CONNECTIONS TO EQUIPMENT TO BE PROVIDED I. INDIRECT DRAIN T&P RELIEF VALVE TO FLOOR DRAIN. <br /> WH-1 VFD VARIABLE FREQUENCY DRIVE ria <br /> WITH A SEDIMENT TRAP WITH EXCEPTION TO CLOTHES J. SET ALL FIXTURE TEMPERATURE LIMIT STOPS TO 110°F UNLESS INDICATED OTHERWISE. FLEXIBLE PIPE CONNECTION SYMBOLS MAY BE a <br /> DRYERS INSTALL ALL GAS CONNECTIONS TO APPLIANCES 399.9 MBH VOL VOLUME <br /> PER MANFUCTURERS RECOMMENDATIONS AND LOCAL K. INSULATE HANDICAP LAVATORY TAIL PIECE, P TRAP,TRAP ARM, HOT AND COLD WATER SUPPLY WITH HANDI LAV GUARD. VTR VENT THROUGH ROOF z REDUCED PRESSURE BACKFLOW PREVENTER USED [If <br /> JURISDICTION REQUIREMENTS. <br /> 1 1/4"o L. ALL DISHWASHERS TO BE PROTECTED AGAINST BACKFLOW BY AN AIR GAP OR BACKFLOW PREVENTER. W/ WITH 0 <br /> LL <br /> WH-2 M. PROVIDE ADEQUATE COMBUSTION,VENTILATION,AND DILUTION AIR FOR ALL GAS FIRED EQUIPMENT PER INTERNATIONAL FUEL GASW/0 WITHOUT DOUBLE CHECK BACKFLOW PREVENTER <br /> F. PROVIDE ACCESS TO ALL VALVES AND REGULATORS. 399.9 MBH DRYER CODE[CALIFORNIA PLUMBING CODE]AND IN ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. J <br /> G. PROVIDE VALVED FINAL CONNECTION TO ALL GAS FIRED 1 1/4"o 225 MBH N. PROVIDE CONCRETE HOUSEKEEPING PAD(MIN 3"ABOVE GROUND LEVEL)FOR ALL WATER HEATERS. WCO WALL CLEANOUT U <br /> EQUIPMENT. 2"o 0. GAS FIRED ROOFTOP UNITS TO BE TESTED IN ACCORDANCE WITH ANSIZ21.40.1 OR ANSIZ21.40.2. WPD WATER PRESSURE DROP <br /> H. VENT ALL REGULATORS TO BUILDING EXTERIOR PER LOCAL DOAS-1 P. CONTRACTOR MUST COORDINATE ALL ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT WITH ELECTRICAL CONTRACTOR ONCE WT WEIGHT <br /> , <br /> JURISDICTION REQUIREMENTS. 2"m 1 1/4"� 399.9 HMBH 405 MBH 1 DRYER GAS PIPINGROVED SUBMITTALS ARE RECEIVED. PLUMBING SHEET INDEX <br /> 1 114"o 270 MBH A. PRIME AND PAINT ALL GAS PIPING LOCATED ON ROOF. ALL PIPING TO BE INSTALLED 4"MINIMUM ABOVE ROOF. <br /> 1 1/2"m SHEET N0. SHEET TITLE REVISION <br /> B. NEW OR MODIFIED GAS PIPING TO BE TESTED AND INSPECTED PER INTERNATIONAL FUEL GAS CODE OR CALIFORNIA MECHANICAL CODE P0.1 GENERAL NOTES, SHEET INDEX,ABBREVIATIONS AND SYMBOLS <br /> 40 FT AND LOCAL JURISDICTION PRIOR TO INITIAL OPERATION. THE TEST PRESSURE TO BE NOT LESS THAN 1-1/2 TIMES THE PROPOSED <br /> 50 FT 30 FT MAXIMUM WORKING PRESSURE,AND NOT LESS THAN 3 PSIG. TEST DURATION TO BE A MINIMUM 10 MINUTES OR NOT LESS THAN 1/2 HOUR P1.1A PLUMBING FLOOR PLAN LEVEL 1 (WASTE,VENT&GAS) 4 <br /> FOR EACH 500 FT3 OF PIPE VOLUME. AREAS OF PIPING WHERE LEAKS OR OTHER DEFECTS ARE LOCATED TO BE REPLACED OR REPAIRED P1.1 B PLUMBING FLOOR PLAN-LEVEL 1 (DOMESTIC COLD WATER) <br /> 1"m <br /> GAS METER AND RETESTED. P1.1 C PLUMBING FLOOR PLAN-LEVEL 1 (DOMESTIC HOT WATER) <br /> 2"D 1 1/4"ro 1 1/4"ro 1 1/4"ro 1 o C. GAS CONNECTION TO APPLIANCE TO BE CSST AND GAS CONNECTION TO COMMERCIAL COOKING APPLIANCE TO COMPLY WITH ANSI P1.2 PLUMBING FLOOR PLAN-LEVEL 2 <br /> Z21.69. CONNECTORS FOR RANGES AND DOMESTIC CLOTHES DRYER TO HAVE A MAXIMUM LENGTH OF 6 FEET. CONNECTORS FOR ALL P1.3 PLUMBING FLOOR PLAN-LEVEL 3 <br /> OTHER APPLIANCES TO HAVE A MAXIMUM LENGTH OF 3 FT. SHUTOFF VALVES TO BE INSTALLED AHEAD OF CONNECTORS. CONNECTOR P1.4 PLUMBING ROOF PLAN <br /> INSTALLATION TO COMPLY WITH MANUFACTURER REQUIREMENTS. P2.1 RISER DIAGRAMS <br /> GENERAL PIPING P5.1 PLUMBING DETAILS <br /> EMERGENCY SEISMIC ACUATED 1 A. PIPING AND EQUIPMENT HANGERS CENTERED ON STEEL I-BEAMS(CONCENTRIC HANGERS)ARE PREFERRED OVER HANGERS SUPPORTED P6.1 PLUMBING SCHEDULES 4 <br /> SHUTOFF - SHUTOFF VALVE TO BE 30 FT FROM A SINGLE SIDE OF THE BOTTOM I-BEAM FLANGE. IF USING HANGERS SUPPORTED FROM A SINGLE SIDE OF THE BOTTOM FLANGE, <br /> VALVE MOUNTED RIGIDLY ON THE MAXIMUM WEIGHT LIMIT PER HANGER IS 200 POUNDS UNLESS DIRECTED OTHERWISE BY THE PROJECT STRUCTURAL ENGINEER. <br /> EXTERIOR WALL PER 1 1/2"o B. CONCEALED VENTS,DUCTS,AND ALL PIPING INSTALLED THROUGH FRAMING MEMBERS MUST BE PROTECTED FROM FASTENER <br /> LOCAL JURISDICTION PENETRATION BY A STEEL SHIELD PLATE(MINIMUM THICKNESS OF 1/16")UNLESS THE DISTANCE FROM THE FACE EDGE OF THE FRAMING <br /> REQUIREMENTS. IS NOT LESS THAN 1.5"' ALL EQUIPMENT SELECTED AT SITE ELEVATION(150')UNLESS NOTED OTHERWISE. <br /> POOL&SPA C. CLOSE ENDS OF PIPING AND COVER FLOOR DRAINS DURING CONSTRUCTION. CLEAN ALL EQUIPMENT AND PIPING AT COMPLETION OF <br /> 600 MBH PROJECT. 6Y <br /> D. COORDINATE ALL STRUCTURAL AND TOP PLATE PENETRATIONS FOR PIPING WITH GENERAL CONTRACTOR AND STRUCTURAL ENGINEER. 0 <br /> E. PROVIDE DRAIN PANS UNDER ALL PIPING LOCATED OVER ELECTRICAL PANELS AND UNDER ALL WATER HEATERS. U) <br /> F. PROVIDE AND INSTALL EXPANSION JOINTS FOR ALL PIPING SYSTEMS PER CODE AND LOCAL JURISDICTION REQUIREMENTS. AT A z <br /> MINIMUM, PROVIDE EXPANSION JOINTS WHEN JOINING SEPARATE PIPING MATERIAL AND FOR ALL DWV AND ROOF DRAIN STACKS SERVING MINIMUM PLUMBING PIPING INSULATION THICKNESS <br /> FLOORS.MORE THAN TWO <br /> GAS PIPING SCHEMATIC SANITARY SEWER,VENT,AND DRAIN FLUID OPERATING TEMPERATURE CONDUCTIVITY MEAN RATING o <br /> NO SCALE A. WASTE PIPING SMALLER THAN 4"IS TO BE SLOPED AT 1/4"PER FOOT ONO.ALL WASTE PIPING 4"AND LARGER MAY BE INSTALLED AT 1/8" SYSTEM TYPES RANGE AND USAGE(°F) (BTU*IN/(h*FT`F)) TEMPERATURE(°F) <1 1 TO<1 112 1 112 TO<4 4 TO<8 >_8 0 <br /> 46SLOPE PER FOOT UPON RECEIVING WRITTEN APPROVAL BY LOCAL JURISDICTION.VERIFY INVERT BEFORE INSTALLATION. DHW(165°F),DHWR(165°F) 141 -200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 U <br /> 3"o Yo B. ALL SANITARY WASTE AND VENT AND STORM DRAINAGE PIPING LOCATED IN A RETURN AIR PLENUM TO BE CAST IRON SV NO HUB SYSTEM. DHW(120°F, 140°F),DHWR <br /> 105-140 0.21 0.28 100 1.0 1.0 1.5 1.5 1.5 <br /> - - C. PROVIDE CLEANOUTS ON INTERIOR SANITARY AND STORM PIPING A MINIMUM OF EVERY 50 FEET AND EVERY 100 FEET ON EXTERIOR (120°F, 140°F) Q <br /> PIPING. DCW 1 40-60 1 0.21 -0.27 1 75 1 0.5 1 0.5 1 1.0 1 1.0 1.0 z 0 <br /> �o - - - - - - - - D. PROVIDE GRADE CLEANOUT WHERE BUILDING SEWER CONNECTS TO SEWAGE SYSTEM. NOTES: U J <br /> E. PROVIDE VENT FOR EVERY TRAP AND TRAPPED FIXTURE.ALL VTR'S TO BE 2"MINIMUM AND TERMINATE MINIMUM 10"ABOVE ROOF AND 1. BASED ON THE 2016 CALIFORNIA ENERGY CODE(CEC). <br /> MINIMUM 24"FROM ROOF EDGE OR PARAPET,AND 25FROM OUTSIDE AIR INTAKE INTO BUILDING. 2. PROVIDE ALUMINUM JACKETS ON ALL PIPING INSULATION LOCATED EXTERIOR OF THE BUILDING. PROVIDE PVC JACKET ON ALL EXPOSED PIPING INSULATION IN <br /> F. PRESSURE TEST ALL SANITARY SEWER AND VENT AND STORM PIPING TO PLUMBING CODE REQUIREMENTS. MECHANICAL ROOM. <br /> 211 2111 2"o---,,2"11 2" 2" PROVIDE BALL G. DRAINAGE CONNECTIONS SHALL NOT BE MADE INTO A DRAINAGE PIPING SYSTEM WITHIN 8'OF ANY VERTICAL TO HORIZONTAL CHANGE 3. INSULATE ALL ROOF DRAIN PIPING WITH MINIMUM 1/2"INSULATION. INSULATE ALL ROOF DRAIN AND OVERFLOW DRAIN BOWLS WITH MINIMUM V INSULATION. INSULATION <br /> VALVE ON VERTICAL OF DIRECTION OF A STACK CONTAINING SUDS.STACKS CONTAINING SUDS ARE IDENTIFIED ON THE RISER DIAGRAMS. TO BE 0.27 BTU*IN/(WFT2*°F). <br /> i PIPE 4. PROVIDE PROTECTIVE SHIELDING PIPE COVERS ON ALL PIPES EXPOSED AT ADA PLUMBING FIXTURES. PROTECTIVE SHIELDING PIPE COVERS TO COMPLY WITH ADA REVISIONS: <br /> E SOLAR PIPING TO REQUIREMENTS. <br /> FUTURE <br /> .92 2"o 2"o ROOF SEE P1.1B 5. REFER TO SPECIFICATIONS FOR ADDITIONAL INSULATION REQUIREMENTS. <br /> SOLARAND PIA FOR <br /> TANK �-g-� CONTINUATION <br /> 3„D 2"o 2"o PLUMBING PIPING MATERIAL SCHEDULE FIXTURE FLOW RATE <br /> FIXTURE MAX FLOW RATE <br /> m WH-3 WH-2 WH-1 DOMESTIC WATER (LOW FLOWS) <br /> BELOW GRADE ASTM B 88 TYPE K SOLDERED COPPER KITCHEN FAUCET 1.8 GPM <br /> ABOVE GRADE ASTM B 88 TYPE L SOLDERED COPPER RESIDENTIAL FAUCET 1.2 GPM <br /> 2"o <br /> GUESTROOMS COPPER MANIFOLDS, 1/2"PEX-A TUBING FROM MANIFOLD TO FIXTURES METERED COMMON AND PUBLIC 0.20 GAL/CYCLE GENERAL SINK 2.2 GPM <br /> - 1"D ET-1 WASTE KITCHEN-EXPOSED ASTM B 88 TYPE L SOLDERED COPPER AREA FAUCETS <br /> - - - - - - - BELOW GRADE ASTM D 2665 PVC SCHEDULE 40,SOCKET FITTINGS DWV BA PROJECT# 161010 <br /> ABOVE GRADE ASTM A 888 CAST IRON,NO HUB SYSTEM SHOWERHEAD 2.0 GPM <br /> E' CP-1 NOTES: FLUSH VALVE WATER CLOSET 1.28 GAL/FLUSH PLN PROJECT# 17077 <br /> I <br /> FLUSH TANK WATER CLOSET 1.28 GAL/FLUSH <br /> CP 2 I 1. NC: NORMALLY CLOSE GREASE WASTE MARRIOTT# 4476 <br /> - 3 2. NO: NORMALLY OPEN ALL ASTM A 88 CAST IRON WITH EPDXY COATING,NO HUB SYSTEM URINAL 0.125 GAL/FLUSH <br /> I - - VENT NOTES: <br /> I 4 A. ONE UNSOFTENED DOMESTIC WATER LINE A. EXCLUDES SERVICE SINKS PERMIT# <br /> U 2" +-2" 3°O <br /> N.C. TO RUN TO SILLCOCKS, POOL,JUICE AND ALL ASTM A 88 CAST IRON, NO HUB SYSTEM <br /> 4"o <br /> COFFEE DISPENSERS,AND DRINKING GAS APN# 058-66-012 <br /> N.O. N <br /> 4„D .O. 4„D FOUNTAINS.SOFTENED DOMESTIC COLD BELOW GRADE ASTM D 2513 POLYETHYLENE <br /> - WATER LINE TO RUN TO ALL OTHER ABOVE GRADE SCHEDULE 40 STEEL TO COMPLY WITH EITHER ASME B36.10,ASTM A 53, <br /> FIXTURES. OR ASTM A 106 <br /> CONDENSATE DRAWN: ACS <br /> DATE: 4/12/19 <br /> 3/4"ro I MV-1 I B. WATER SOFTENER IS SHOWN AS ONE TANK <br /> FOR CLARITY. REFER TO FLOOR PLANS AND <br /> 4 INDOORS ASTM D 2665 PVC SCHEDULE 40,SOCKET FITTINGS DWV <br /> 5-$ -DHWR-165° WATER SOFTENER SCHEDULE ON SHEET CHECKED: HS <br /> 2"o - - 4"o P6.1 FOR WATER SOFTENER SIZE. OUTDOORS ASTM B 88 TYPE L COPPER <br /> JJ I CATEGORY IV ASTM D 2665 PVC SCHEDULE 40,SOCKET FITTINGS DWV <br /> TO BUILDING 5- -DHWR-120° 3"D I NOTES: <br /> 2"o 2%j <br /> 1. REFER TO SPECIFICATIONS FOR ADDITIONAL PIPING REQUIREMENTS. SHEET TITLE: <br /> TO LAUNDRY 5- _� - DHW-165°F- - f� I 2. PROVIDE DIELECTRIC FITTINGS FOR ALL DISSIMILAR METALS. GENERAL NOTES, <br /> 3"owS-1 SHEET INDEX, <br /> TO BUILDING -DHW-120°- f ABBREVIATIONS AND <br /> 4 <br /> SYMBOLS <br /> TO BUILDING � � -SDCW- � <br /> N.C. 4"� <br /> TO BUILDING S q U-DCW 1Q <br /> FROM BP-1 <br /> 2"o 4,I,ro <br /> C <br /> d <br /> SHEET NO.: <br /> 3 <br /> so <br /> 2 WATER SCHEMATIC <br /> NO SCALE <br /> P0 . 1 <br />