NKEYNOTES: <br /> 1. BALL VALVE(TYP). U <br /> _ 2. UNION (TYP). KEYNOTES: LLj- <br /> 3. WATER HEATER(TYP). KEYNOTES: <br /> 4. P&T RELIEF VALVE-INDIRECT TO NEAREST 1. SINGLE PLY ROOF JACK FURNISHED <br /> FLOOR SINK/DRAIN(TYP). 1. PUMP DISCHARGE-TO WATER HEATER/ _ z AND INSTALLED BY ROOFING <br /> O N 5. DHW OUTLET. MIXING VALVE. CONTRACTOR.SEAL WATERTIGHT TO r 1 <br /> 6. DCW INLET. 2. BALL VALVE(TYP). 1 2 VENT STACK <br /> 3. CHECK VALVE(TYP). <br /> M 5 ' U NOTES: 4. CIRC PUMP WITH INTEGRAL TEMPERATURE 2. ROOFING MATERIAL <br /> c SENSOR. <br /> A. PROVIDE EACH WATER HEATER WITH ® 5. AUTOMATIC AIR VENT(TYP). 3. SLEEVE ROOF CONSTRUCTION AS RED INC ARCHITECTS <br /> SEISMIC STRAPS LOCATED 1/3 OF THE 5 6. PUMP INLET. REQUIRED 1217J STREET,MODESTO,CA 95354 <br /> WATER HEATER'S HEIGHT FROM THE 7 7 7. TEMPERATURE GAUGE. 209.522.8900 <br /> BOTTOM TO TOP OF THE WATER HEATER. 32 1 4. VENT STACK <br /> SECURE STRAPS TO WALL. 6 NOTES: SEAL: <br /> B. PROVIDE CONDENSATE DRAIN IF REQUIRED. 5. INCREASER WHEN REQUIRED <br /> ROUTE TO NEAREST FLOOR SINK. A. PUMP TO VARY FLOW TO MAINTAIN <br /> C. PROVIDE THERMO WELL AT THE INLET AND SETPOINT RETURN WATER TEMPERATURE. <br /> OUTLET OF EACH CONNECTION TO B. PUMPS TO ALTERNATE OPERATION. 3 <br /> . <br /> EQUIPMENT. QROF oN <br /> N STg7C F2 <br /> m <br /> � 2 <br /> w M37119 <br /> 3 lip, oHAA\Fo <br /> Im <br /> COI <br /> 0 4 04/12/2019 <br /> In <br /> m <br /> CONSULTANT: <br /> 5 DUAL HOTWATER RECIRC PUMP riVENT THROUGH ROOF <br /> l NO SCALE -I <br /> NO SCALE <br /> �d <br /> a <br /> 2 KEYNOTES: KEYNOTES: <br /> 1, GYPSUM WALL BOARD 1. CLEANOUT AND ACCESS COVER. [7 <br /> TOP OF COVER TO BE FLUSH W/ <br /> LL 2. 4"DIAMETER OR LESS TYPE TOP OF FLOOR ENGINEERING SYSTEM SOLUTIONS <br /> STRUCTURAL•MEP•BUILDING COMMISSIONIN <br /> L COPPER DOMESTIC WATER 2. FLOOR LINE BUILDING RE <br /> PIPE, OR 10"DIAMETER 1 4 EXCEEDING EXPECTATION <br /> SHIPS S <br /> www. <br /> om <br /> 6 LESS CAST IRON WASTE AND 2 3 ORTH29THE ST <br /> 3. BRASS CLEANOUT PLUG W/ <br /> VENT PIPE. a943 DA NORTH <br /> COUNTER SUNK HEAD roABOFALLs,IDAxos3am <br /> 3. 3M FB 3000 WT SEALANT 4. FINISH GRADE <br /> to <br /> JOB NUMBER: 17.1019 <br /> TRESE EETEPLANS,DMWEJOS AIm DESWNS ARE THEE-SNE PROPERTYOF E- <br /> SYSTEMSTIONSANDSHALLNOTBE -EDMAN -MWITHOUT <br /> NOTES: WRITTEN <br /> OLA <br /> 5. 16"SQUARE CONC. PAD TROWEL CONS-A-E-E °"B'°M BIaEN°wEE"B"°SYSTEM <br /> s°LLT'°"s <br /> 3 <br /> 0 2 A, MINIMUM ANNULAR SPACE SMOOTH AND EDGE <br /> BETWEEN PIPE AND OPENING 6 6 5 6. 1/8"BEND <br /> IS 3/4". _ <br /> B. INSTALL FIRE STOP 10 7. WASTE LINE.LENGTH TO SUIT <br /> COMPOUND TO A DEPTH OF FLOOR CLEANOUT(FCO) 7 8. WASTE LINE <br /> 1/2" FOR EACH SIDE TO A <br /> MINIMUM OF 1 1/2"THICK. 9. Fa, re)9 BTU WATER HEATER CONNECTIONS 3 WATER HEATERS 1/8"BEND IF CLEANOUT OCCURS AT END OF LINE <br /> P5.1 NO SCALE 1 C. INSTALL PER o <br /> MANUFACTURER'S 8 10. BALANCE OF PIPING SAME AS <br /> RECOMMENDATION TO 9 CLEANOUT TO GRADE [BY M Q K IR0 Oo T T <br /> MAINTAIN ASSEMBLY RATING. NOTES: <br /> KEYNOTES: CLEANOUT TO GRADE(COTG) <br /> A. CLEANOUT NOT TO BE LOCATED IN <br /> *BRINE TANK 1. BLENDING VALVE., CARPETED AREA <br /> 2. SENSING LINES. <br /> 3. NG COCK.THROTTLING GLOBE VALVE. <br /> MINERALTANK MINERALTANK 2 UNION <br /> 4. UNION(TYP). j-� PIPING PENETRATION AT ONE HOUR RATED WALL ASSEMBLY 2 CLEANOUT <br /> 6 <br /> 14 5. FLOW METER(TYP). NO SCALE �� NO SCALE <br /> 9 7 6. ISOLATION VALVE. <br /> X11 7. HARD WATER LINE. <br /> 8. MANUAL BYPASS VALVE. NORMALLY <br /> KEYNOTES: Q <br /> 5 12 4 9. MANUAL INLET ISOLATION VALVE(TYP). KEYNOTES: 2 1. CHROME WALL COVER AND SCREW z <br /> Lu [If <br /> 3 10. CONTROLLER(TYP). 1. SUB FLOOR <br /> 11 2. MAY EXTEND AS A WASTE OR <br /> 11. MANUAL OUTLET ISOLATION VALVE(TYP). <br /> 12. 4"THICK HOUSKEEPING PAD. 2, FLOOR JOIST VENT LINE Q <br /> 6 13. FLOOR SLAB. <br /> 3, 3M FB 3000 WT SEALANT 1 3 3. WALL U <br /> 4. 4"DIAMETER OR LESS TYPE 4. PLUGGED TEE <br /> L COPPER DOMESTIC WATER <br /> 1 PIPE, OR 10"DIAMETER 4 5. WASTE OR VENT PIPING <br /> LESS CAST IRON WASTE AND <br /> 6. FLOOR LINE <br /> VENT PIPE. <br /> 2 NOTES: <br /> A. MINIMUM ANNULAR SPACE <br /> BETWEEN PIPE AND OPENING _ <br /> 13 IS 3/4". <br /> 14 <br /> B. INSTALL FIRE STOP 5 <br /> 10 WATER SOFTENER DETAIL COMPOUND"ON EACH SSIDEDTO A EPTH OF o o <br /> NO SCALE 3 MINIMUM OF 1 1/2"THICK. 6 <br /> C. INSTALL PER a <br /> MANUFACTURER'S <br /> KEYNOTES: 4 RECOMMENDATION TO <br /> MAINTAIN ASSEMBLY RATING. <br /> 1. SPLASH BLOCK. <br /> 2. COPPER DRAIN THRU WALL. <br /> 4 5 3. REFER TO DRAWINGS FOR CONDENSATE PIPING PENETRATION AT ONE HOUR RTD FLR/CLG ASSEMBLY 3 WALL CLEANOUT <br /> ROUTING. ROUTE ALL CONDENSATE ON <br /> U WARM SIDE OF INSULATION. P51 NO SCALE P5.1 NO SCALE z_ ULF <br /> 4. DRAIN FROM UNIT INTO DRAIN STACK TO4 O <br /> m 2 TAIL PIECE. <br /> 5. PTAC. o 2 <br /> O_ <br /> 46 -71 FLOOR <br /> U <br /> 5 6 KEYNOTES: 2 KEYNOTES: <br /> • 3 ° U) D <br /> 1. BALL VALVE(TYP). 3 1- 1/4" MINIMUM DIAMETER BEAD OF 3M o <br /> 2. STRAINER(TYP). FIRE BARRIER CP 25 CAULK OR MP <br /> 3 3. CHECK VALVE(TYP). MOLDABLE PUTTY <br /> 4. TEMP SENSOR. <br /> 5. MIXED WATER OUTLET. <br /> 6. FROM RECIRCULATION PUMPS. 2. WOOD OR STEEL STUD <br /> 7. HOT WATER FROM HOT WATER HEATERS. 1 <br /> 1 8. TO HOT WATER SUPPLY. 3. 1 OR 2 HOUR FIRE RATED GYPSUM REVISIONS: <br /> III III 9. COLD WATER INLET. <br /> WALLBOARD <br /> III <br /> 10.ARMSTRONG DVR MIXING VALVE. <br /> NOTES: <br /> 1 <br /> 7 2 A. INSTALL PER MANUFACTURERS <br /> B RECOMMENDATIONS.DETAIL FOR NOTE: <br /> u REFERENCE ONLY. TYPICAL DETAILS SHOWING GENERAL FIRE <br /> STO <br /> 11 CONDENSATE DRAIN STACK o PROCEDURE DEPENDS UPON ANNULAR <br /> NO SCALE 10 1 SPACE BETWEEN PIPE AND/OR INSULATION <br /> AND OPENING. FOLLOW MANUFACTURER'S <br /> INSTRUCTIONS. <br /> m BA PROJECT# 161010 <br /> NOTES(CONT.): KEYNOTES: PLN PROJECT# 17077 <br /> 2 1 MARRIOTT# 4476 <br /> D. INSTALL TRAP PRIMER IN ACCESSIBLE 1. AVOID DIRECT INSTALLATION TO PREVENT <br /> LOCATION. PROVIDE ACCESS PANEL IF FOREIGN MATERIAL FROM ENTERING <br /> NECESSARY.COORDINATE ACCESS PANEL DIRECTLY INTO PRIMER. 9 8 FIRESTOP FOR PIPING THROUGH GYPSUM WALL BOARD <br /> U 3 WITH GENERAL CONTRACTOR/ARCHITECT. 2. LINE SHUT OFF VALVE. PERMIT# - <br /> cb; E. CONNECT ONLY TO THE BRANCH PIPING OF 3. UNION CONNECTION. APN# 058-66-012 <br /> 5 4 FIXTURES THAT SEE FREQUENT USE. 4. TRAP PRIMER VALVE. 8 DRV 50 4 FIRESTOP FOR PIPING THROUGH GYPSUM WALLS <br /> 5. FILTER SCREEN. <br /> Q6. FOUR VIEW HOLES. NO SCALE N51 NO SCALE <br /> 7. MI-GAP AIR GAP FITTING. DATE: 4/12/19 <br /> 8. TRAP PRIMER SHOULD BE MOUNTED ONE <br /> DRAWN: ACS <br /> FOOT ABOVE THE FINISHED FLOOR FOR <br /> EVERY 20 FEET OF PRIMER LINE. <br /> CHECKED: HS <br /> 9. WATER TRAP. <br /> 7 <br /> 10. SEWER GAS. <br /> 11. FLOOR DRAIN/SINK TRAP PRIMER <br /> CONNECTION. <br /> SHEET TITLE: <br /> NOTES: PLUMBING DETAILS <br /> A. APPLIES TO ALL DRAINS/FLOOR SINKS <br /> UNLESS NOTED OTHERWISE. <br /> B. DO NOT INSTALL THE TRAP SEAL PRIMERS <br /> J> 11 10 CLOSER THAN 40'APART WHEN USING THE <br /> SAME POTABLE WATER SUPPLY LINE. <br /> 9 C. THE DEVICE SHOULD BE LOCATED WITHIN <br /> 20'OF THE VALVE OR FAUCET FOR <br /> OPTIMAL DISCHARGE. <br /> c <br /> 2 PRESSURE DROP ACTIVATED TRAP PRIMER SHEET NO.: <br /> NO SCALE <br /> L <br /> r <br /> P5. 1 <br />