My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
INSTALL_1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 4:58:34 PM
Creation date
5/6/2020 2:47:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1999
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. Prior to tank lining, a site assessment must be performed under the direction of Public Health Services <br /> Environmental Health Division (PHS-EHD), site mitigation unit. <br /> Site Assessment has been performed under PHS-EHD direction <br /> "-' Site Assessment has not been performed under PHS-EHD direction. Please contact PHS-EHD site <br /> Migation unit at(209)468-3449 <br /> 2. Reason tanks will be interior lined/repaired: <br /> •// Meet State/Federal upgrade requirements (submit PHS-EHD UST upgrade permit application with <br /> this application) <br /> Tank system failure, please describe: <br /> S,&-fig w0_\A cr�U�S c,w4Lc' \m A* <br /> 3. The following tests are required to be performed prior to lining to determine the structural integrity of the <br /> UST: <br /> Steel tanks <br /> Ultrasound The UST shall be closed in accordance with Article 7 Title 23 CCR if the <br /> nk' verage metal thi ness is less than 75 percent of the original wall thickness of if the tank <br /> has any of the listed defe is in Article 6, Title 23 CCR section 2663 (b) (2) (B)) <br /> Certification by a "Special Inspector" that the tank is structurally sound for tank lining and continued <br /> use: <br /> a. sandblast to whit metal <br /> _b. count number of ho s, splits, perforations, and other defects <br /> ----c. submit result to EHD <br /> Non-steel tanks, fiberglass <br /> Certification by a "Special Inspector"that the tank is suitable for lining. <br /> _a. interior walls cleaned by wipe down <br /> b. interior diameter measurements <br /> c. visual check for structural, tension, or compression problems <br />
The URL can be used to link to this page
Your browser does not support the video tag.