My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
INSTALL_1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 4:58:34 PM
Creation date
5/6/2020 2:47:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1999
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
04.26.99 15: 14 FAX 425 251 8182 BARGHAL'SEN 2011 <br /> 04/26/1999 07:11 7146785429 EHS ARCO LA PALMA PAGE 13 <br /> MONITORIN9AND RESPONSE PLAN S-0 <br /> ARCO PRODUCTS COMPANY FACILITY W" <br /> pIgPENSER >a14L CONTAINMENT DEVICES <br /> Address: /7// E. 5l9fEMiTr J <br /> Ve-11 <br /> ARCO Facility: (COWm�,7-cam � 953'310 <br /> This is a monitoring and response plan of action for facilities with spill <br /> containment devicsa inszafled beneath the dispensers. <br /> 1, CONTAINMENT EQUIPMENT <br /> Dispenser spill containment devices (box(es)l are located beneath <br /> each dispenser to contain any leafs from components and fittings <br /> inside the dispenser cabinet. A mechanical sensor is located in the <br /> box. When the sensor detects the presence of a liquid, it will activate <br /> the impact valve and shut the dispenser down. <br /> 2. MAINTgNANgE SCHEDUL9 <br /> The containment devices will be inspected according to the ` <br /> manufacturer's instructions by an outside contractor once during each <br /> calendar year. <br /> 3. kOUTINE MONrMRIN�j PROgEDIJRE <br /> On a weekly basis the facility operator shall: <br /> A. Inspect each.containment box for the presence of a liquid. <br /> 8. Remove debris from the containment box. <br /> If any liquid Is found, manually close the lrrpacz valve, pace the <br /> dispenser 'out of service"; and call ARCO Maintenance immediately. <br /> 4. REPONSE PROCEDURE - PONTAINMENT BOXES <br /> OPERATOR RESPONSISILITIES <br /> In the event the impact valve is activated and shuts down a <br /> dispenser., station personnel immediately: <br />