5608 N PERSHING AVE
<br /> PAGE 3
<br /> The 10,000 gallon regular gasoline tank, located southernmost in the tank pit area, showed
<br /> TPH as gasoline and BTEX at 3.4 ppm, less than 0.05 ppm,less than 0.1 ppm, less than 0.1
<br /> ppm,less than 0.1 ppm,respectively,for the western sample and showed TPH as gasoline and
<br /> BTEX at 3800 ppm,less than 0.05 ppm, 160 ppm,77 ppm,and 430 ppm,respectively,for the
<br /> eastern sample. EDB was not detected at a detection limit of 0.5 ppm.
<br /> PIPING
<br /> The piping results showed nondetect for TPH as gasoline and BTEX in three samples,but
<br /> showed TPH as gasoline and BTEX at 720 ppm, 10 ppm, 62 ppm, 19 ppm, and 100 ppm,
<br /> respectively,in sample LT-1, located in the area where the piping entered the tank pit area,
<br /> along the southern edge of the building. The other sample to show TPH as gasoline and
<br /> BTEX at 8.0 ppm,0.39 ppm, 1.5 ppm,0.22 ppm,and 1.1 ppm,respectively,was LT-3,located
<br /> along the western wall of the building, near the southern corner. All samples showed
<br /> nondetect for EDB at a detection limit of 0.5 ppm.
<br /> WASTE OIL PIT
<br /> The waste oil tank showed TPH as diesel at 49 ppm, BTEX at less than 0.05 ppm, less than
<br /> 0.1 ppm, 0.11 ppm, and 0.89 ppm, respectively. Cadmium, chromium, lead, nickel and zinc
<br /> were detected at 0.14 ppm, 40 ppm, 6.1 ppm, 45 ppm, and 46 ppm, respectively. Arsenic,
<br /> beryllium, copper, selenium and silver were also detected at 14 ppm, 0.40 ppm,33 ppm,2.4
<br /> ppm,and 0.21 ppm,respectively. The halogenated volatile compound(EPA 5030/8010) 1,13-
<br /> trichloroethane was detected at 0.015 ppm,and the following semi-volatile compounds (EPA
<br /> 355018270) were detected' benzo(a)anthracene at 0.250 ppm, bis(2-ethylhexyl)phthalate at
<br /> 1.500 ppm, chrysene at 0.180 ppm, fluoranthene at 0.270 ppm,2-methylnaphthalene at 1.400
<br /> PPM, napthalene at 0.770 ppm, pentachlorophenol at 0.220 ppm, and pyrene at 0.330 ppm.
<br /> The laboratory also found some other semi-volatile organics by mass spectrometry, but they
<br /> were not confirmed with standards.
<br /> 09-14-88 Monitoring wells MW#1 through MW#7 sampled this date. Depth to water was
<br /> approximately 29'- 30' BGS. Flow direction was to the north northeast.
<br /> MW#1 showed TPH as gasoline, BTEX and 1, 2-DCA at 530 ppb, 120 ppb, 49 ppb, 15 ppb,
<br /> 79 ppb, and 0.4 ppb, respectively.
<br /> MW#2 showed TPH as gasoline, BTEX and 1,2-DCA at 350 ppb, 99 ppb, 29 ppb, 11 ppb,
<br /> 44 ppb, and 0.3 ppb, respectively.
<br /> MW#3 was not sampled. MW#4 showed TPH as gasoline,BTEX and 1,2-DCA at 150 ppb,
<br /> 2.8 ppb, less than 1.0 ppb, less than 1.0 ppb, less than 1.0 ppb, and less than 1.0 ppb,
<br /> respectively.
<br /> MW#5 showed TPH as gasoline,BTEX and 1,2-DCA at 50 ppb, less than 0.1 ppb,less than
<br /> 1.0 ppb, less than 1.0 ppb, less than 1.0 ppb, and less than 0.1 ppb, respectively.
<br /> MW#6 showed TPH as gasoline,BTEX and 1,2-DCA at 240 ppb,3.4 ppb, less than 1.0 ppb,
<br /> less than 1.0 ppb, less than 1.0 ppb, and 0.7 ppb, respectively.
<br /> MW#7 showed TPH as gasoline,BTEX and 1,2-DCA at 270 ppb,less than 0.1 ppb,less than
<br /> 1.0 ppb, less than 1.0 ppb, less than 1.0 ppb, and 0.2 ppb, respectively.
<br /> 10-04-88 PHS/EHD receives a copy of a letter workplan from RPs consultant to the RB outlining a
<br /> nlan to do vapor extraction in the tank pit and waste oil tank pit areas and to drill peripheral
<br />
|