5608 N PERSHING AVE <br /> PAGE 3 <br /> The 10,000 gallon regular gasoline tank, located southernmost in the tank pit area, showed <br /> TPH as gasoline and BTEX at 3.4 ppm, less than 0.05 ppm,less than 0.1 ppm, less than 0.1 <br /> ppm,less than 0.1 ppm,respectively,for the western sample and showed TPH as gasoline and <br /> BTEX at 3800 ppm,less than 0.05 ppm, 160 ppm,77 ppm,and 430 ppm,respectively,for the <br /> eastern sample. EDB was not detected at a detection limit of 0.5 ppm. <br /> PIPING <br /> The piping results showed nondetect for TPH as gasoline and BTEX in three samples,but <br /> showed TPH as gasoline and BTEX at 720 ppm, 10 ppm, 62 ppm, 19 ppm, and 100 ppm, <br /> respectively,in sample LT-1, located in the area where the piping entered the tank pit area, <br /> along the southern edge of the building. The other sample to show TPH as gasoline and <br /> BTEX at 8.0 ppm,0.39 ppm, 1.5 ppm,0.22 ppm,and 1.1 ppm,respectively,was LT-3,located <br /> along the western wall of the building, near the southern corner. All samples showed <br /> nondetect for EDB at a detection limit of 0.5 ppm. <br /> WASTE OIL PIT <br /> The waste oil tank showed TPH as diesel at 49 ppm, BTEX at less than 0.05 ppm, less than <br /> 0.1 ppm, 0.11 ppm, and 0.89 ppm, respectively. Cadmium, chromium, lead, nickel and zinc <br /> were detected at 0.14 ppm, 40 ppm, 6.1 ppm, 45 ppm, and 46 ppm, respectively. Arsenic, <br /> beryllium, copper, selenium and silver were also detected at 14 ppm, 0.40 ppm,33 ppm,2.4 <br /> ppm,and 0.21 ppm,respectively. The halogenated volatile compound(EPA 5030/8010) 1,13- <br /> trichloroethane was detected at 0.015 ppm,and the following semi-volatile compounds (EPA <br /> 355018270) were detected' benzo(a)anthracene at 0.250 ppm, bis(2-ethylhexyl)phthalate at <br /> 1.500 ppm, chrysene at 0.180 ppm, fluoranthene at 0.270 ppm,2-methylnaphthalene at 1.400 <br /> PPM, napthalene at 0.770 ppm, pentachlorophenol at 0.220 ppm, and pyrene at 0.330 ppm. <br /> The laboratory also found some other semi-volatile organics by mass spectrometry, but they <br /> were not confirmed with standards. <br /> 09-14-88 Monitoring wells MW#1 through MW#7 sampled this date. Depth to water was <br /> approximately 29'- 30' BGS. Flow direction was to the north northeast. <br /> MW#1 showed TPH as gasoline, BTEX and 1, 2-DCA at 530 ppb, 120 ppb, 49 ppb, 15 ppb, <br /> 79 ppb, and 0.4 ppb, respectively. <br /> MW#2 showed TPH as gasoline, BTEX and 1,2-DCA at 350 ppb, 99 ppb, 29 ppb, 11 ppb, <br /> 44 ppb, and 0.3 ppb, respectively. <br /> MW#3 was not sampled. MW#4 showed TPH as gasoline,BTEX and 1,2-DCA at 150 ppb, <br /> 2.8 ppb, less than 1.0 ppb, less than 1.0 ppb, less than 1.0 ppb, and less than 1.0 ppb, <br /> respectively. <br /> MW#5 showed TPH as gasoline,BTEX and 1,2-DCA at 50 ppb, less than 0.1 ppb,less than <br /> 1.0 ppb, less than 1.0 ppb, less than 1.0 ppb, and less than 0.1 ppb, respectively. <br /> MW#6 showed TPH as gasoline,BTEX and 1,2-DCA at 240 ppb,3.4 ppb, less than 1.0 ppb, <br /> less than 1.0 ppb, less than 1.0 ppb, and 0.7 ppb, respectively. <br /> MW#7 showed TPH as gasoline,BTEX and 1,2-DCA at 270 ppb,less than 0.1 ppb,less than <br /> 1.0 ppb, less than 1.0 ppb, less than 1.0 ppb, and 0.2 ppb, respectively. <br /> 10-04-88 PHS/EHD receives a copy of a letter workplan from RPs consultant to the RB outlining a <br /> nlan to do vapor extraction in the tank pit and waste oil tank pit areas and to drill peripheral <br />