Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> AMENDED <br /> E= <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: FDte: <br /> ARCO 06080 85 E LOUISE AVE, LATHROP nuary 29, 2018 <br /> UST System Observations <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty ❑V n R u COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements u V u R n COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden n V n R u COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ri V u R u COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status D V n R u COS <br /> 324 CCR 2717.1(g) Tampered with red tag n V D R D COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V D R u COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms n V D R n COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V D R D COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V D R n COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements o V o R D COS <br /> _............... <br /> 330 CCR 2636(1)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V D R ❑COS <br /> 331 CCR 2630(d) Secondarily contained piping not maintained to allow liquid to drain into sump a V ❑R D COS <br /> 332 CCR 2631(b),2631(d) Primary and/or secondary containment not constructed in accordance with the established standards n V a R D COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve u V c R D COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed n V u R u COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V D R n COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V ❑R u COS <br /> Other Violations <br /> 2010 See below Unlisted General violation n V ❑R u COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. Accurate location of annular sensor is not identified. A <br /> site plan must be submitted identifying the locations where monitoring will be performed. Immediately log into the <br /> California Environmental Reporting System(CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST <br /> Monitoring Site Plan. <br /> This is a minor violation. <br /> FA0003635 PR0231656 SCO01 01/29/2018 <br /> EHD 23-01 Rev.1 0/3 112 01 7 Page 3 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />