Laserfiche WebLink
1 3.05 TRUSS OR TENSION RODS <br /> 2 <br /> 3 End, latch, and corner posts shall be braced to the nearest line post. At the Contractor's <br /> 4 option bracing shall be accomplished either with diagonal braces used as compression <br /> 5 members or with horizontal braces used as compression members and truss rods used as <br /> s tension members. Each truss rod shall be equipped with a turnbuckle or truss tightener <br /> 7 with tensile strength equal to the truss rod. Line posts shall be braced horizontally and <br /> a trussed in both directions at intervals not to exceed 1,000 feet, except that this bracing and <br /> 9 trussing may be omitted when the fabric is installed by stretching with equipment. <br /> 10 <br /> 11 <br /> 12 <br /> 13 <br /> ' 14 <br /> 15 END OF SECTION <br /> i <br /> 1 <br /> 1 <br /> i <br /> M <br /> 1 <br /> 1 <br /> CHAIN LINK FENCE <br /> 042894 02445-3 <br />