Laserfiche WebLink
I joints shall be located midway between downspout outlets and shall fall on a four (4) foot r <br /> 2 module. The joint shall be of a design which will provide watertight connection and permit <br /> 3 freedom of movement of the gutter lining. <br /> 4 <br /> s 3.02 SHOP PAINTING <br /> 6 <br /> 7 Galvanized steel, except as otherwise specified, shall be given a shop treatment of copper , <br /> 8 acetate solution of 6 ounces of copper acetate to one gallon of water, followed by a brush <br /> 9 or spray-coat of specified galvanized metal primer. <br /> 10 <br /> 11 3.03 ASSEMBLIES <br /> 12 <br /> 13 Fabricate assemblies from materials and of gauges indicated or specified. Where material <br /> 14 is not indicated, fabricate from zinc coated steel not less than 26 gauge, aluminum not less <br /> 15 than 20 gauge. <br /> 16 <br /> 17 1. Seal between laps of expansion joints of gutters, flashing, etc., with butyl sealing tape. <br /> 18 <br /> 19 2. Cleats supporting bottom edge of edging, etc., shall be continuous; secure on not <br /> 20 more than 12 inch centers. <br /> 21 <br /> zz 3. Secure deck flanges of edging, etc., on not more than 4 inch centers. <br /> 23 <br /> 24 i 2s <br /> 26 <br /> 27 <br /> 26 <br /> 29 END OF SECTION <br /> 1 <br /> FLASHING AND SHEET METAL <br /> 050694 07620-4 <br />